1,319 research outputs found

    Faraday waves on a viscoelastic liquid

    Full text link
    We investigate Faraday waves on a viscoelastic liquid. Onset measurements and a nonlinear phase diagram for the selected patterns are presented. By virtue of the elasticity of the material a surface resonance synchronous to the external drive competes with the usual subharmonic Faraday instability. Close to the bicriticality the nonlinear wave interaction gives rise to a variety of novel surface states: Localised patches of hexagons, hexagonal superlattices, coexistence of hexagons and lines. Theoretical stability calculations and qualitative resonance arguments support the experimental observations.Comment: 4 pages, 4figure

    Pattern formation in 2-frequency forced parametric waves

    Full text link
    We present an experimental investigation of superlattice patterns generated on the surface of a fluid via parametric forcing with 2 commensurate frequencies. The spatio-temporal behavior of 4 qualitatively different types of superlattice patterns is described in detail. These states are generated via a number of different 3--wave resonant interactions. They occur either as symmetry--breaking bifurcations of hexagonal patterns composed of a single unstable mode or via nonlinear interactions between the two primary unstable modes generated by the two forcing frequencies. A coherent picture of these states together with the phase space in which they appear is presented. In addition, we describe a number of new superlattice states generated by 4--wave interactions that arise when symmetry constraints rule out 3--wave resonances.Comment: The paper contains 34 pages and 53 figures and provides an extensive review of both the theoretical and experimental work peformed in this syste

    Association of British Neurologists: revised (2015) guidelines for prescribing disease-modifying treatments in multiple sclerosis.

    Get PDF
    In June 1999, the Association of British Neurologists (ABN) first published guidelines for the use of the licensed multiple sclerosis (MS) disease-modifying treatments (at that time β-interferon and glatiramer acetate). The guidelines were revised in 2001 and have been periodically updated since then. In 2002, following the negative assessment of these treatments by the National Institute for Health and Care Excellence (NICE), the MS risk-sharing scheme started, in which patients eligible according to the 2001 ABN guidelines were provided with treatment funded through the UK National Health Service (NHS), and monitored annually for up to 10 years.1 Recruitment to the risk-sharing scheme cohort is complete. Pending a future final evaluation, the UK Department of Health's instruction to NHS funders remains in place: that patients who fulfil the ABN criteria should continue to receive treatment funded through the NHS. The British neurological community has fully accepted the risk-sharing scheme for prescribing β-interferon and glatiramer acetate. Approximately 70 ‘treating centres’ have recruited >5000 patients between 2002 and 2005, and these have been monitored annually for 10 years; many more patients have received these treatments since 2005. The ABN published revised guidelines in 2007, and then again in 2009, following the licensing of natalizumab and mitoxantrone. This 2015 revised guideline replaces former versions. It includes all newly approved or licensed treatments for MS and represents a consensus concerning their use. These guidelines will require future revision as other treatments receive approval (eg, daclizumab and ocrelizumab): we suggest they are reviewed after an interval of no longer than 12 months. The guideline is not intended to provide a complete description of the possible complications and monitoring of disease-modifying treatments in MS; we refer prescribing neurologists to the relevant summaries of product characteristics.PostprintPeer reviewe

    ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy Spectroscopic Instrument

    Full text link
    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the universe using the baryon acoustic oscillations technique. The spectra of 35 million galaxies and quasars over 14,000 square degrees will be measured during a 5-year survey. A new prime focus corrector for the Mayall telescope at Kitt Peak National Observatory will deliver light to 5,000 individually targeted fiber-fed robotic positioners. The fibers in turn feed ten broadband multi-object spectrographs. We describe the ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall telescope from August 14 to September 30, 2016. ProtoDESI was an on-sky technology demonstration with the goal to reduce technical risks associated with aligning optical fibers with targets using robotic fiber positioners and maintaining the stability required to operate DESI. The ProtoDESI prime focus instrument, consisting of three fiber positioners, illuminated fiducials, and a guide camera, was installed behind the existing Mosaic corrector on the Mayall telescope. A Fiber View Camera was mounted in the Cassegrain cage of the telescope and provided feedback metrology for positioning the fibers. ProtoDESI also provided a platform for early integration of hardware with the DESI Instrument Control System that controls the subsystems, provides communication with the Telescope Control System, and collects instrument telemetry data. Lacking a spectrograph, ProtoDESI monitored the output of the fibers using a Fiber Photometry Camera mounted on the prime focus instrument. ProtoDESI was successful in acquiring targets with the robotically positioned fibers and demonstrated that the DESI guiding requirements can be met.Comment: Accepted versio

    Precision alignment and integration of DESI's focal plane using a laser tracker

    Get PDF
    The recently commissioned Dark Energy Spectroscopic Instrument (DESI) will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sq deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope delivers light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. We describe the use of a Faro Laser Tracker with custom hardware and software tools for alignment during integration of DESI’s focal plane. The focal plane is approximately one meter in diameter and consists primarily of ten radially symmetrical focal plane segments (“petals”) which were individually installed into the telescope. The nominal clearance between petals is 600 microns, and an alignment accuracy of 100 microns and 0.01 degrees was targeted. Alignment of the petals to their targeted locations on the telescope was accomplished by adjusting a purpose-built alignment structure with 14 degrees of freedom using feedback from the laser tracker, which measured the locations of retroreflectors attached to both the petal and the telescope and whose positions relative to key features were precisely known. These measurements were used to infer the locations of aligning features in both structures, which were in turn used to calculate the adjustments necessary to bring the system into alignment. Once alignment was achieved to within acceptable tolerances, each petal was installed while monitoring building movement due to wind and thermal variations

    Teaching Hospital Five-Year Mortality Trends in the Wake of Duty Hour Reforms

    Get PDF
    Background The Accreditation Council for Graduate Medical Education (ACGME) implemented duty hour regulations for residents in 2003 and again in 2011. While previous studies showed no systematic impacts in the first 2 years post-reform, the impact on mortality in subsequent years has not been examined. OBJECTIVE To determine whether duty hour regulations were associated with changes in mortality among Medicare patients in hospitals of different teaching intensity after the first 2 years post-reform. DESIGN Observational study using interrupted time series analysis with data from July 1, 2000 to June 30, 2008. Logistic regression was used to examine the change in mortality for patients in more versus less teaching-intensive hospitals before (2000–2003) and after (2003–2008) duty hour reform, adjusting for patient comorbidities, time trends, and hospital site. PATIENTS Medicare patients (n  = 13,678,956) admitted to short-term acute care non-federal hospitals with principal diagnoses of acute myocardial infarction (AMI), gastrointestinal bleeding, or congestive heart failure (CHF); or a diagnosis-related group (DRG) classification of general, orthopedic, or vascular surgery. MAIN MEASURE All-location mortality within 30 days of hospital admission. KEY RESULTS In medical and surgical patients, there were no consistent changes in the odds of mortality at more vs. less teaching intensive hospitals in post-reform years 1–3. However, there were significant relative improvements in mortality for medical patients in the fourth and fifth years post-reform: Post4 (OR 0.88, 95 % CI [0.93–0.94]); Post5 (OR 0.87, [0.82–0.92]) and for surgical patients in the fifth year post-reform: Post5 (OR 0.91, [0.85–0.96]). CONCLUSIONS Duty hour reform was associated with no significant change in mortality in the early years after implementation, and with a trend toward improved mortality among medical patients in the fourth and fifth years. It is unclear whether improvements in outcomes long after implementation can be attributed to the reform, but concerns about worsening outcomes seem unfounded

    Development of Complex Mathematical Model of Light Naphtha Isomerization and Rectification Processes

    Get PDF
    The technique of developing a mathematical model of catalytic isomerization of light naphtha is stated Using experimental data from an industrial isomerization unit shows adequacy of the mathematical model to the real process. The paper presents a method for optimizing the operation of the plant together with catalytic isomerization unit and separation columns. Selection of optimal modes of separation columns allows achieving the desired flow separation between units, as well as extension of the life of the catalyst SI-2

    On Various Ways of Measuring Unemployment, with Applications to Switzerland

    Full text link
    This paper discusses first various ways of measuring unemployment and, borrowing ideas from the poverty measurement literature, proposes four more general unemployment indices which are parallel to Sen poverty index, to its generalization by Shorrocks, to the FGT, and to the Watts poverty indices. It then presents an empirical illustration based on Swiss data at the level of the “canton.” More precisely, using the so-called Shapley decomposition, it computes the contribution to the difference between the value of each of these four unemployment indices in a given “canton” and in Switzerland as a whole, of three components measuring, respectively, the impact of differences in the traditional unemployment rate, in the average unemployment duration, and in the inequality in the unemployment durations. The paper ends by discussing the impact on the results obtained of assumptions made concerning the maximum unemployment duration
    corecore