51 research outputs found

    Gas modulation refractometry (GAMOR) - On its ability to eliminate the influence of drifts

    Get PDF
    Gas modulation refractometry (GAMOR) is a technique based on a dual-Fabry-Perot (FP) cavity (DFPC) for assessment of gas refractivity, density, and pressure that can alleviate significant limitations of conventional refractometry systems, predominantly those related to drifts. Repeated assessments of the beat frequency when the measurement cavity is evacuated provide conditions under which the methodology is immune to the linear parts of the drifts in the system, both those from length changes of the cavities and those from gas leaks and outgassing. This implies that the technique is solely influenced by the non-linear parts of the drifts. This work provides a description of the principle behind the GAMOR methodology and explicates the background to its unique property. Based on simple models of the drifts of the temperature in the cavity spacer and the residual gas in the reference cavity, this work predicts that a GAMOR system, when used for assessment of refractivity, can sustain significant temperature drifts and leakage rates without being affected by noticeable errors or uncertainties. The cavity spacer can be exposed to temperature fluctuations of 100 mK over 103 s, and the reference cavity can have a leakage that fills it up with gas on a timescale of days, without providing errors or uncertainties in the assessment of refractivity that are 3 x 10^(-12), which, for N2, corresponds to 0.01 ppm (parts per million) of the value under atmospheric pressure conditions, and thereby 1 mPa. Since well-designed systems often have temperature fluctuations and leakage rates that are smaller than these, it is concluded that there will, in practice, not be any appreciable influence from cavity length drifts, gas leaks, and outgassing in the GAMOR methodology

    Sub-Doppler optical-optical double-resonance spectroscopy using a cavity-enhanced frequency comb probe

    Full text link
    Accurate parameters of molecular hot-band transitions, i.e., those starting from vibrationally excited levels, are needed to accurately model high-temperature spectra in astrophysics and combustion, yet laboratory spectra measured at high temperatures are often unresolved and difficult to assign. Optical-optical double-resonance (OODR) spectroscopy allows the measurement and assignment of individual hot-band transitions from selectively pumped energy levels without the need to heat the sample. However, previous demonstrations lacked either sufficient resolution, spectral coverage, absorption sensitivity, or frequency accuracy. Here we demonstrate OODR spectroscopy using a cavity-enhanced frequency comb probe that combines all these advantages. We detect and assign sub-Doppler transitions in the 3ν{\nu}3{_3}{\leftarrow}ν{\nu}3{_3} spectral range of methane with frequency accuracy and sensitivity more than an order of magnitude better than before. This technique will provide high-accuracy data about excited states of a wide range of molecules that is urgently needed for theoretical modeling of high-temperature data and cannot be obtained using other methods

    Demonstration of a Transportable Fabry–Pérot Refractometer by a Ring-Type Comparison of Dead-Weight Pressure Balances at Four European National Metrology Institutes

    Get PDF
    Fabry–Pérot-based refractometry has demonstrated the ability to assess gas pressure with high accuracy and has been prophesized to be able to realize the SI unit for pressure, the pascal, based on quantum calculations of the molar polarizabilities of gases. So far, the technology has mostly been limited to well-controlled laboratories. However, recently, an easy-to-use transportable refractometer has been constructed. Although its performance has previously been assessed under well-controlled laboratory conditions, to assess its ability to serve as an actually transportable system, a ring-type comparison addressing various well-characterized pressure balances in the 10–90 kPa range at several European national metrology institutes is presented in this work. It was found that the transportable refractometer is capable of being transported and swiftly set up to be operational with retained performance in a variety of environments. The system could also verify that the pressure balances used within the ring-type comparison agree with each other. These results constitute an important step toward broadening the application areas of FP-based refractometry technology and bringing it within reach of various types of stakeholders, not least within industry

    Kavitetsförstärkt optisk detektion

    No full text
    An optical cavity comprises a set of mirrors between which light can be reflected a number of times. The selectivity and stability of optical cavities make them extremely useful as frequency references or discri­mi­nators. With light coupled into the cavity, a sample placed inside a cavity will experience a significantly increased interaction length. Hence, they can be used also as amplifiers for sensing purposes. In the field of laser spectroscopy, some of the most sensitive techniques are therefore built upon optical cavities. In this work optical cavities are used to measure properties of gas samples, i.e. absorption, dispersion, and refractivity, with unprecedented precision. The most sensitive detection technique of all, Doppler-broadened noise-immune cavity enhanced optical heterodyne molecular spectrometry (Db NICE-OHMS), has in this work been developed to an ultra-sensitive spectroscopic technique with unprecedented detection sensitivity. By identifying limiting factors, realizing new experimental setups, and deter­mining optimal detection conditions, the sensitivity of the technique has been improved several orders of magnitude, from 8 × 10-11 to 9 × 10-14 cm-1. The pressure interval in which NICE-OHMS can be applied has been extended by deri­vation and verification of dispersions equations for so-called Dicke narrowing and speed dependent broadening effects. The theoretical description of NICE-OHMS has been expanded through the development of a formalism that can be applied to the situations when the cavity absorption cannot be considered to be small, which has expanded the dynamic range of the technique. In order to enable analysis of a large number of molecules at their most sensitive transitions (mainly their funda­mental CH vibrational transitions) NICE-OHMS instrumentation has also been developed for measurements in the mid-infrared (MIR) region. While it has been difficult to realize this in the past due to a lack of optical modulators in the MIR range, the system has been based on an optical para­metric oscillator, which can be modulated in the near-infrared (NIR) range. As the index of refraction can be related to density, it is possible to retrieve gas density from measurements of the index of refraction. Two such instru­men­tations have been realized. The first one is based on a laser locked to a measure­ment cavity whose frequency is measured by compassion with an optical frequency comb. The second one is based on two lasers locked to a dual-cavity (i.e. one reference and one measurement cavity). By these methods changes in gas density down to 1 × 10-9 kg/m3 can be detected. All instrumentations presented in this work have pushed forward the limits of what previously has been considered measurable. The knowledge acquired will be of great use for future ultrasensitive cavity-based detection methods

    Kavitetsförstärkt optisk detektion

    No full text
    An optical cavity comprises a set of mirrors between which light can be reflected a number of times. The selectivity and stability of optical cavities make them extremely useful as frequency references or discri­mi­nators. With light coupled into the cavity, a sample placed inside a cavity will experience a significantly increased interaction length. Hence, they can be used also as amplifiers for sensing purposes. In the field of laser spectroscopy, some of the most sensitive techniques are therefore built upon optical cavities. In this work optical cavities are used to measure properties of gas samples, i.e. absorption, dispersion, and refractivity, with unprecedented precision. The most sensitive detection technique of all, Doppler-broadened noise-immune cavity enhanced optical heterodyne molecular spectrometry (Db NICE-OHMS), has in this work been developed to an ultra-sensitive spectroscopic technique with unprecedented detection sensitivity. By identifying limiting factors, realizing new experimental setups, and deter­mining optimal detection conditions, the sensitivity of the technique has been improved several orders of magnitude, from 8 × 10-11 to 9 × 10-14 cm-1. The pressure interval in which NICE-OHMS can be applied has been extended by deri­vation and verification of dispersions equations for so-called Dicke narrowing and speed dependent broadening effects. The theoretical description of NICE-OHMS has been expanded through the development of a formalism that can be applied to the situations when the cavity absorption cannot be considered to be small, which has expanded the dynamic range of the technique. In order to enable analysis of a large number of molecules at their most sensitive transitions (mainly their funda­mental CH vibrational transitions) NICE-OHMS instrumentation has also been developed for measurements in the mid-infrared (MIR) region. While it has been difficult to realize this in the past due to a lack of optical modulators in the MIR range, the system has been based on an optical para­metric oscillator, which can be modulated in the near-infrared (NIR) range. As the index of refraction can be related to density, it is possible to retrieve gas density from measurements of the index of refraction. Two such instru­men­tations have been realized. The first one is based on a laser locked to a measure­ment cavity whose frequency is measured by compassion with an optical frequency comb. The second one is based on two lasers locked to a dual-cavity (i.e. one reference and one measurement cavity). By these methods changes in gas density down to 1 × 10-9 kg/m3 can be detected. All instrumentations presented in this work have pushed forward the limits of what previously has been considered measurable. The knowledge acquired will be of great use for future ultrasensitive cavity-based detection methods
    corecore