123 research outputs found
A Comparison and Joint Analysis of Sunyaev-Zel'dovich Effect Measurements from Planck and Bolocam for a set of 47 Massive Galaxy Clusters
We measure the SZ signal toward a set of 47 clusters with a median mass of
M and a median redshift of 0.40 using data from
Planck and the ground-based Bolocam receiver. When Planck XMM-like masses are
used to set the scale radius , we find consistency between
the integrated SZ signal, , derived from Bolocam and Planck
based on gNFW model fits using A10 shape parameters, with an average ratio of
(allowing for the % Bolocam flux calibration
uncertainty). We also perform a joint fit to the Bolocam and Planck data using
a modified A10 model with the outer logarithmic slope allowed to vary,
finding (measurement error followed by
intrinsic scatter). In addition, we find that the value of scales with
mass and redshift according to . This mass scaling is in good agreement with recent
simulations. We do not observe the strong trend of with redshift seen
in simulations, though we conclude that this is most likely due to our sample
selection. Finally, we use Bolocam measurements of to test the
accuracy of the Planck completeness estimate. We find consistency, with the
actual number of Planck detections falling approximately below the
expectation from Bolocam. We translate this small difference into a constraint
on the the effective mass bias for the Planck cluster cosmology results, with
.Comment: Updated to include one additional co-author. Also some minor changes
to the text based on initial feedbac
Thermodynamic Profiles of Galaxy Clusters from a Joint X-ray/SZ Analysis
We jointly analyze Bolocam Sunyaev-Zeldovich (SZ) effect and Chandra X-ray
data for a set of 45 clusters to derive gas density and temperature profiles
without using spectroscopic information. The sample spans the mass and redshift
range
and . We define cool-core (CC) and non-cool core (NCC)
subsamples based on the central X-ray luminosity, and 17/45 clusters are
classified as CC. In general, the profiles derived from our analysis are found
to be in good agreement with previous analyses, and profile constraints beyond
are obtained for 34/45 clusters. In approximately 30% of the CC
clusters our analysis shows a central temperature drop with a statistical
significance of ; this modest detection fraction is due mainly to a
combination of coarse angular resolution and modest S/N in the SZ data. Most
clusters are consistent with an isothermal profile at the largest radii near
, although 9/45 show a significant temperature decrease with
increasing radius. The sample mean density profile is in good agreement with
previous studies, and shows a minimum intrinsic scatter of approximately 10%
near . The sample mean temperature profile is consistent
with isothermal, and has an intrinsic scatter of approximately 50% independent
of radius. This scatter is significantly higher compared to earlier X-ray-only
studies, which find intrinsic scatters near 10%, likely due to a combination of
unaccounted for non-idealities in the SZ noise, projection effects, and sample
selection.Comment: 42 pages, 52 figure
The Status of MUSIC: The Multiwavelength Sub/millimeter Inductance Camera
The Multiwavelength Sub/millimeter Inductance Camera (MUSIC) is a four-band photometric imaging camera operating from the Caltech Submillimeter Observatory (CSO). MUSIC is designed to utilize 2304 microwave kinetic inductance detectors (MKIDs), with 576 MKIDs for each observing band centered on 150, 230, 290, and 350 GHz. MUSIC’s field of view (FOV) is 14′ square, and the point-spread functions (PSFs) in the four observing bands have 45′′, 31′′, 25′′, and 22′′ full-widths at half maximum (FWHM). The camera was installed in April 2012 with 25% of its nominal detector count in each band, and has subsequently completed three short sets of engineering observations and one longer duration set of early science observations. Recent results from on-sky characterization of the instrument during these observing runs are presented, including achieved map- based sensitivities from deep integrations, along with results from lab-based measurements made during the same period. In addition, recent upgrades to MUSIC, which are expected to significantly improve the sensitivity of the camera, are described
The cryomechanical design of MUSIC: a novel imaging instrument for millimeter-wave astrophysics at the Caltech Submillimeter Observatory
MUSIC (Multicolor Submillimeter kinetic Inductance Camera) is a new facility instrument for the Caltech Submillimeter Observatory (Mauna Kea, Hawaii) developed as a collaborative effect of Caltech, JPL, the University of Colorado at Boulder and UC Santa Barbara, and is due for initial commissioning in early 2011. MUSIC utilizes a new class of superconducting photon detectors known as microwave kinetic inductance detectors (MKIDs), an emergent technology that offers considerable advantages over current types of detectors for submillimeter and millimeter direct detection. MUSIC will operate a focal plane of 576 spatial pixels, where each pixel is a slot line antenna coupled to multiple detectors through on-chip, lumped-element filters, allowing simultaneously imaging in four bands at 0.86, 1.02, 1.33 and 2.00 mm. The MUSIC instrument is designed for closed-cycle operation, combining a pulse tube cooler with a two-stage Helium-3 adsorption refrigerator, providing a focal plane temperature of 0.25 K with intermediate temperature stages at approximately 50, 4 and 0.4 K for buffering heat loads and heat sinking of optical filters. Detector readout is achieved using semi-rigid coaxial cables from room temperature to the focal plane, with cryogenic HEMT amplifiers operating at 4 K. Several hundred detectors may be multiplexed in frequency space through one signal line and amplifier. This paper discusses the design of the instrument cryogenic hardware, including a number of features unique to the implementation of superconducting detectors. Predicted performance data for the instrument system will also be presented and discussed
The Panchromatic Hubble Andromeda Treasury II. Tracing the Inner M31 Halo with Blue Horizontal Branch Stars
We attempt to constrain the shape of M31's inner stellar halo by tracing the
surface density of blue horizontal branch (BHB) stars at galactocentric
distances ranging from 2 kpc to 35 kpc. Our measurements make use of resolved
stellar photometry from a section of the Panchromatic Hubble Andromeda Treasury
(PHAT) survey, supplemented by several archival Hubble Space Telescope
observations. We find that the ratio of BHB to red giant stars is relatively
constant outside of 10 kpc, suggesting that the BHB is as reliable a tracer of
the halo population as the red giant branch. In the inner halo, we do not
expect BHB stars to be produced by the high metallicity bulge and disk, making
BHB stars a good candidate to be a reliable tracer of the stellar halo to much
smaller galactocentric distances. If we assume a power-law profile r^(-\alpha)
for the 2-D projected surface density BHB distribution, we obtain a
high-quality fit with a 2-D power-law index of \alpha=2.6^{+0.3}_{-0.2} outside
of 3 kpc, which flattens to \alpha<1.2 inside of 3 kpc. This slope is
consistent with previous measurements but is anchored to a radial baseline that
extends much farther inward. Finally, assuming azimuthal symmetry and a
constant mass-to-light ratio, the best-fitting profile yields a total halo
stellar mass of 2.1^{+1.7}_{-0.4} x 10^9 M_sun. These properties are comparable
with both simulations of stellar halo formation formed by satellite disruption
alone, and with simulations that include some in situ formation of halo stars.Comment: 15 pages, 1 table, 5 figures, accepted for publication in Ap
A Comparison and Joint Analysis of Sunyaev-Zel'dovich Effect Measurements from Planck and Bolocam for a set of 47 Massive Galaxy Clusters
We measure the Sunyaev–Zel'dovich (SZ) signal toward a set of 47 clusters with a median mass of 9.5 × 10^(14) M_☉ and a median redshift of 0.40 using data from Planck and the ground-based Bolocam receiver. When Planck XMM-like masses are used to set the scale radius θ_s, we find consistency between the integrated SZ signal, Y_(5R500), derived from Bolocam and Planck based on generalized Navarro, Frenk, and White model fits using A10 shape parameters, with an average ratio of 1.069 ± 0.030 (allowing for the ≃ 5% Bolocam flux calibration uncertainty). We also perform a joint fit to the Bolocam and Planck data using a modified A10 model with the outer logarithmic slope β allowed to vary, finding β = 6.13 ± 0.16 ± 0.76 (measurement error followed by intrinsic scatter). In addition, we find that the value of β scales with mass and redshift according to β ∝ M^(0.077 ± 0.026) x (1 + z))^(-0.06 ± 0.09). This mass scaling is in good agreement with recent simulations. We do not observe the strong trend of β with redshift seen in simulations, though we conclude that this is most likely due to our sample selection. Finally, we use Bolocam measurements of Y 500 to test the accuracy of the Planck completeness estimate. We find consistency, with the actual number of Planck detections falling approximately 1σ below the expectation from Bolocam. We translate this small difference into a constraint on the effective mass bias for the Planck cluster cosmology results, with (1 - b)=0.93 ± 0.06
MKID multicolor array status and results from DemoCam
We present the results of the latest multicolor Microwave Kinetic Inductance Detector (MKID) focal plane arrays in the submillimeter. The new detectors on the arrays are superconducting resonators which combine a coplanar waveguide section with an interdigitated capacitor, or IDC. To avoid out-of-band pickup by the capacitor, a stepped-impedance filter is used to prevent radiation from reaching the absorptive aluminum section of the resonator. These arrays are tested in the preliminary demonstration instrument, DemoCam, a precursor to the Multicolor Submillimeter Inductance Camera, MUSIC. We present laboratory results of the responsivity to light both in the laboratory and at the Caltech Submillimeter Observatory. We assess the performance of the detectors in filtering out-of-band radiation, and find the level of excess load and its effect on detector performance. We also look at the array design characteristics, and the implications for the optimization of sensitivities expected by MUSIC
- …