55 research outputs found

    First data from the CUPID-Mo neutrinoless double beta decay experiment

    Get PDF

    A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors

    Full text link
    We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal sensors and an electrode design (ID) which allows to efficiently reject several sources of background. The data indicate no evidence for an exponential distribution of low-energy nuclear recoils that could be attributed to WIMP elastic scattering after an exposure of 113 kg.d. For WIMPs of mass 10 GeV, the observation of one event in the WIMP search region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent WIMP-nucleon scattering cross-section, which constrains the parameter space associated with the findings reported by the CoGeNT, DAMA and CRESST experiments.Comment: PRD rapid communication accepte

    Background studies for the EDELWEISS dark matter experiment

    Full text link
    The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter using cryogenic Ge detectors (400 g each) and 384 kg×\timesdays of effective exposure. A cross-section of 4.4×1084.4 \times 10^{-8} pb is excluded at 90% C.L. for a WIMP mass of 85 GeV. The next phase, EDELWEISS-III, aims to probe spin-independent WIMP-nucleon cross-sections down to a few ×109\times10^{-9} pb. We present here the study of gamma and neutron background coming from radioactive decays in the set-up and shielding materials. We have carried out Monte Carlo simulations for the completed EDELWEISS-II setup with GEANT4 and normalised the expected background rates to the measured radioactivity levels (or their upper limits) of all materials and components. The expected gamma-ray event rate in EDELWEISS-II at 20-200 keV agrees with the observed rate of 82 events/kg/day within the uncertainties in the measured concentrations. The calculated neutron rate from radioactivity of 1.0-3.1 events (90% C.L.) at 20-200 keV in the EDELWEISS-II data together with the expected upper limit on the misidentified gamma-ray events (0.9\le0.9), surface betas (0.3\le0.3), and muon-induced neutrons (0.7\le0.7), do not contradict 5 observed events in nuclear recoil band. We have then extended the simulation framework to the EDELWEISS-III configuration with 800 g crystals, better material purity and additional neutron shielding inside the cryostat. The gamma-ray and neutron backgrounds in 24 kg fiducial mass of EDELWEISS-III have been calculated as 14-44 events/kg/day and 0.7-1.4 events per year, respectively. The results of the background studies performed in the present work have helped to select better purity components and improve shielding in EDELWEISS-III to further reduce the expected rate of background events in the next phase of the experiment.Comment: 15 pages, 9 figures, to be published in Astroparticle Physic

    Muon-induced background in the EDELWEISS dark matter search

    Full text link
    A dedicated analysis of the muon-induced background in the EDELWEISS dark matter search has been performed on a data set acquired in 2009 and 2010. The total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was measured to be Φμ=(5.4±0.20.9+0.5)\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})\,muons/m2^2/d. The modular design of the muon-veto system allows the reconstruction of the muon trajectory and hence the determination of the angular dependent muon flux in LSM. The results are in good agreement with both MC simulations and earlier measurements. Synchronization of the muon-veto system with the phonon and ionization signals of the Ge detector array allowed identification of muon-induced events. Rates for all muon-induced events Γμ=(0.172±0.012)evts/(kgd)\Gamma^{\mu}=(0.172 \pm 0.012)\, \rm{evts}/(\rm{kg \cdot d}) and of WIMP-like events Γμn=0.0080.004+0.005evts/(kgd)\Gamma^{\mu-n} = 0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d}) were extracted. After vetoing, the remaining rate of accepted muon-induced neutrons in the EDELWEISS-II dark matter search was determined to be Γirredμn<6104evts/(kgd)\Gamma^{\mu-n}_{\rm irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d}) at 90%\,C.L. Based on these results, the muon-induced background expectation for an anticipated exposure of 3000\,\kgd\ for EDELWEISS-3 is N3000kgdμn<0.6N^{\mu-n}_{3000 kg\cdot d} < 0.6 events.Comment: 21 pages, 16 figures, Accepted for publication in Astropart. Phy

    Axion searches with the EDELWEISS-II experiment

    Full text link
    We present new constraints on the couplings of axions and more generic axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS experiment, located at the Underground Laboratory of Modane, primarily aims at the direct detection of WIMPs using germanium bolometers. It is also sensitive to the low-energy electron recoils that would be induced by solar or dark matter axions. Using a total exposure of up to 448 kg.d, we searched for axion-induced electron recoils down to 2.5 keV within four scenarios involving different hypotheses on the origin and couplings of axions. We set a 95% CL limit on the coupling to photons gAγ<2.13×109g_{A\gamma}<2.13\times 10^{-9} GeV1^{-1} in a mass range not fully covered by axion helioscopes. We also constrain the coupling to electrons, gAe<2.56×1011g_{Ae} < 2.56\times 10^{-11}, similar to the more indirect solar neutrino bound. Finally we place a limit on gAe×gANeff<4.70×1017g_{Ae}\times g_{AN}^{\rm eff}<4.70 \times 10^{-17}, where gANeffg_{AN}^{\rm eff} is the effective axion-nucleon coupling for 57^{57}Fe. Combining these results we fully exclude the mass range 0.91eV<mA<800.91\,{\rm eV}<m_A<80 keV for DFSZ axions and 5.73eV<mA<405.73\,{\rm eV}<m_A<40 keV for KSVZ axions

    Optimizing EDELWEISS detectors for low-mass WIMP searches

    Get PDF
    The physics potential of EDELWEISS detectors for the search of low-mass weakly interacting massive particles (WIMPs) is studied. Using a data-driven background model, projected exclusion limits are computed using frequentist and multivariate analysis approaches, namely, profile likelihood and boosted decision tree. Both current and achievable experimental performances are considered. The optimal strategy for detector optimization depends critically on whether the emphasis is put on WIMP masses below or above ∼5  GeV/c2. The projected sensitivity for the next phase of the EDELWEISS-III experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon cross section of σSI=7×10−42  cm2 is expected for a WIMP mass in the range 2–5  GeV/c2. The requirements for a future hundred-kilogram-scale experiment designed to reach the bounds imposed by the coherent scattering of solar neutrinos are also described. By improving the ionization resolution down to 50  eVee, we show that such an experiment installed in an even lower background environment (e.g., at SNOLAB) together with an exposure of 1000   kg⋅yr, should allow us to observe about 80 8B neutrino events after discrimination

    Complete event-by-event α/γ(β) separation in a full-size TeO2 CUORE bolometer by simultaneous heat and light detection

    Get PDF
    The CUORE project began recently a search for neutrinoless double-beta decay (0νββ0\nu\beta\beta) of 130^{130}Te with a O\mathcal{O}(1 ton) TeO2_2 bolometer array. In this experiment, the background suppression relies essentially on passive shielding, material radiopurity and anti-coincidences. The lack of particle identification in CUORE makes α\alpha decays at the detector surface the dominant background, at the level of \sim0.01 counts/(keV kg y) in the region of interest (QQ-value of 0νββ0\nu\beta\beta of the order of 2.5 MeV). In the present work we demonstrate, for the first time with a CUORE-size (5×\times5×\times5 cm) TeO2_2 bolometer and using the same technology as CUORE for the readout of the bolometric signals, an efficient α\alpha particle discrimination (99.9\%) with a high acceptance of the 0νββ0\nu\beta\beta signal (about 96\%). This unprecedented result was possible thanks to the superior performance (10 eV RMS baseline noise) of a Neganov-Luke-assisted germanium bolometer used to detect a tiny (70 eV) light signal dominated by γ\gamma(β\beta)-induced Cherenkov radiation in the TeO2_2 detector. The obtained results represent a major breakthrough towards the TeO2_2-based version of CUPID, a ton-scale cryogenic 0νββ0\nu\beta\beta experiment proposed as a follow-up to CUORE with particle identification

    Signals induced by charge-trapping in EDELWEISS FID detectors: Analytical modeling and applications

    Get PDF
    The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields (< 1 V/cm), and as a consequence charge-carrier trapping significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID detectors based on the Shockley-Ramo theorem. It is used to demonstrate that veto electrodes, initially designed for the sole purpose of surface event rejection, can be used to provide a sensitivity to the depth of the energy deposits, characterize the trapping in the crystals, perform heat and ionization energy corrections and improve the ionization baseline resolutions. These procedures are applied successfully to actual data
    corecore