829 research outputs found
Examination on total ozone column retrievals by Brewer spectrophotometry using different processing software
The availability of long-term records of the total ozone content (TOC) represents a valuable source of information for studies on the assessment of short-and long-term atmospheric changes and their impact on the terrestrial ecosystem. In particular, ground-based observations represent a valuable tool for validating satellite-derived products. To our knowledge, details about software packages for processing Brewer spectrophotometer measurements and for retrieving the TOC are seldom specified in studies using such datasets. The sources of the differences among retrieved TOCs from the Brewer instruments located at the Italian stations of Rome and Aosta, using three freely available codes (Brewer Processing Software, BPS; O3Brewer software; and European Brewer Network (EUBREWNET) level 1.5 products) are investigated here. Ground-based TOCs are also compared with Ozone Monitoring Instrument (OMI) TOC retrievals used as an independent dataset since no other instruments near the Brewer sites are available. The overall agreement of the BPS and O3Brewer TOC data with EUBREWNET data is within the estimated total uncertainty in the retrieval of total ozone from a Brewer spectrophotometer (1%). However, differences can be found depending on the software in use. Such differences become larger when the instrumental sensitivity exhibits a fast and dramatic drift which can affect the ozone retrievals significantly. Moreover, if daily mean values are directly generated by the software, differences can be observed due to the configuration set by the users to process single ozone measurement and the rejection rules applied to data to calculate the daily value. This work aims to provide useful information both for scientists engaged in ozone measurements with Brewer spectrophotometers and for stakeholders of the Brewer data products available on Web-based platforms
Ground-based NO2 measurements at the Italian Brewer stations: A pilot study with Global Ozone Monitoring Experiment (GOME)
Ground-based NO2 total column measurements have been collected since 1992 using Brewer spectrophotometry at Rome, an urban site, and Ispra (semirural). These are the only ground-based stations regularly monitoring NO2 in Italy. The methodology of measurement together with the procedure to control its quality is described. From the analysis of the time series it was found that the mean value
of the NO2 column is 1.63 DU atRome and 1.60 DU atIspra. A firstat tempt to compare NO2 vertical column densities (VCD) from GOME with those derived from ground-based Brewer measurements, under different atmospheric conditions and measurement time lags is here presented. The results of this pilot study showed unsatisfactory agreement because different atmospheres are probed by GOME and Brewer instruments. The GOME space resolution resulted insufficient to fully characterize the Rome and Ispra highly localized polluted areas
Ground-based NO2 measurements at the Italian Brewer stations: A pilot study with Global Ozone Monitoring Experiment (GOME)
Ground-based NO2 total column measurements have been collected since 1992 using Brewer spectrophotometry at Rome, an urban site, and Ispra (semirural). These are the only ground-based stations regularly monitoring NO2 in Italy. The methodology of measurement together with the procedure to control its quality is described. From the analysis of the time series it was found that the mean value
of the NO2 column is 1.63 DU atRome and 1.60 DU atIspra. A firstat tempt to compare NO2 vertical column densities (VCD) from GOME with those derived from ground-based Brewer measurements, under different atmospheric conditions and measurement time lags is here presented. The results of this pilot study showed unsatisfactory agreement because different atmospheres are probed by GOME and Brewer instruments. The GOME space resolution resulted insufficient to fully characterize the Rome and Ispra highly localized polluted areas
PEEK Retainers without CAD-CAM: Simple Solutions for Everyday Challenges
Background: The need to perform occasional or continuous MRI exams and the interference with metal orthodontic appliances might be important and take a primary role during retention since the retention period is significantly longer than orthodontic treatment. Several non-metallic materials were proposed as potential alternatives to perform fixed retainers in orthodontics, but they showed internal limits. Methods: Polyetheretherketone (PEEK) was used in the present clinical report as a fixed orthodontic retainer in the lower arch in order to perform an appliance with mechanical properties comparable to metallic ones but with a higher biocompatibility material and without the need for removal in case of an MRI exam. The retainer wire was handmade in the studio and then shaped to fit the arch. Results: PEEK showed a good capability for constructing a lingual fixed retainer compared to other aesthetic non-metallic and metallic materials. Conclusions: To the best of our knowledge, this study proposes how to easily build a retainer in PEEK and provides a clinical example of how this material can be beneficial
Aerosol Single Scattering Albedo retrieval in the UV range: an application to OMI satellite validation
Abstract. The aerosol Single Scattering Albedo (SSA) and Absorbing Aerosol Optical Depth (AAOD) at 320.1 nm are derived at Rome site by the comparison between Brewer and modelled spectra. The UVSPEC radiative transfer model is used to calculate the UV irradiances for different SSA values, taking into account as input data total ozone and Aerosol Optical Depth (AOD) obtained from Brewer spectral measurements. The accuracy in determining SSA depends on the aerosol amount and on Solar Zenith Angle (SZA) value: SSA uncertainty increases when AOD and SZA decrease. The monthly mean values of SSA and AAOD during the period January 2005–June 2008 are analysed, showing a monthly and seasonal variability. It is found that the SSA and AAOD averages are 0.80±0.08 and 0.056±0.028, respectively. AAOD retrievals are also used to quantify the error in the Ozone Monitoring Instrument (OMI) surface UV products due to absorbing aerosols, not included in the current OMI UV algorithm. OMI and Brewer UV irradiances at 324.1 nm and Erythemal Dose Rates (EDRs) under clear sky conditions, are compared as a function of AAOD. Three methods are considered to investigate on the applicability of an absorbing aerosol correction on OMI UV data at Rome site. Depending on the correction methodology, the bias value decreases from 18% to 2% for spectral irradiance at 324.1 nm and from 25% to 8% for EDR
From 3-Port to New Laparoendoscopic Single-Site (LESS) Cholecystectomy : A Critical Analysis of Available Evidence.
In recent years, laparoendoscopic single-site surgery (LESS) has gained greater interest and diffusion for the treatment of gallstones. This critical review aims to evaluate the feasibility and safety of LESS cholecystectomy versus the 3-port technique (TPT) through a comparative analysis of 5 parameters: mean operative time, intraoperative and postoperative complications, conversion to open, conversion to the 4-trocar technique and postoperative hospital stay. The authors performed a systematic search of the medical literature through a search of PubMed and Ovid EMBASE. Inclusion criteria were as follows: publication date between January 1, 2005, and December 31, 2010; English or Italian language; human participants and series of 20 operations or more. There were 5 manuscripts meeting the inclusion criteria for TPT and 23 for LESS. Only one prospective randomized controlled trial comparing TPT and LESS was identified. Operative time is significantly longer in the single-incision group. Complications and conversion rates to the 4-port technique are higher in LESS. Postoperative hospital stay is similar in the 2 groups. Rate of conversion to open is higher in TPT. Despite the number of publications on LESS cholecystectomy, the vast majority of data available in the literature are from small case series without any comparative data. Although LESS cholecystectomy is a fashionable technique there are few data available for an evidence-based determination as to the real benefits of this technique. Well-designed comparative studies are suggested to validate the clinical benefits and ensure that there are no new complications or added costs associated with the new technique
The role of urban boundary layer investigated with high-resolution models and ground-based observations in Rome area: a step towards understanding parameterization potentialities
Abstract. The urban forcing on thermodynamical conditions can greatly influence the local evolution of the atmospheric boundary layer. Heat stored in an urban environment can produce noteworthy mesoscale perturbations of the lower atmosphere. The new generation of high-resolution numerical weather prediction models (NWP) is nowadays often applied also to urban areas. An accurate representation of cities is key role because of the cities' influence on wind, temperature and water vapor content of the planetary boundary layer (PBL). The Advanced Weather Research and Forecasting model WRF (ARW) has been used to reproduce the circulation in the urban area of Rome. A sensitivity study is performed using different PBL and surface schemes. The significant role of the surface forcing in the PBL evolution has been investigated by comparing model results with observations coming from many instruments (lidar, sodar, sonic anemometer and surface stations). The impact of different urban canopy models (UCMs) on the forecast has also been investigated. One meteorological event will be presented, chosen as statistically relevant for the area of interest. The WRF-ARW model shows a tendency to overestimate the vertical transport of horizontal momentum from upper levels to low atmosphere if strong large-scale forcing occurs. This overestimation is partially corrected by a local PBL scheme coupled with an advanced UCM. Moreover, a general underestimation of vertical motions has been verified
Indications to total thyroidectomy for multinodular goiter in old patients
Background: In Western society, the percentage of elderly people is
continually growing. The prevalence of goiter increases with the age and it
is estimated that 90% of women over 60 years old and 60% of men over
80 years old have a relief of thyroid nodules. This has great importance for
these patients, because the incidence of malignant transformation is higher
than younger ones and these are often tumor very aggressive patterns. If
thyroidectomy is indicated for patients with suspected neoplasm and severe
obstructive symptoms, their surgery should not be delayed since a late
urgent operation could raise morbidity and mortality risk. The main
indications for young patients are due to obstructive and metabolic causes
over and above suspected cancer.
Total thyroidectomy is considered by many authors as the treatment of
choice.
Materials and methods: 75 elderly patients were submitted to
thyroidectomy. The indications were metabolic (42.6%), obstructive (32%)
and for suspected cancer (25.4%).
Results: The most frequent complications observed with respect to young
patients in different series have been cardiovascular, pulmonary or
urological. Regarding the complications directly related to thyroidectomy,
there were no differences compared to younger groups, except transient
complications (hypoparathyroidism, seroma). In our experience, the main
complication was represented by hypocalcemia (30.6%), permanent in 8% of
cases. Cancer was relieved in 21.3% of cases.
Prognosis has been excellent in most cases, with immediate remission of
symptoms related to thyrotoxicosis and to tracheal and esophageal
compression in almost all symptomatic patients.
Conclusions: Age is an independent prognostic factor for cancers. It has
been demonstrated that elderly patients with PTC that are operated have
better prognosis and quality of life due to the resolution of dyspnea and
dysphagia. In our experience, we think that age is not a contraindication to
thyroid surgery
Review on Occupational Personal Solar UV Exposure Measurements
During leisure time, people can decide if they want to expose themselves to solar ultraviolet (UV) radiation and to which extent. During occupation, people do not have this choice. Outdoor workers are exposed to solar UV radiation (UVR) on a daily basis. This may hold a certain health risk, which can be estimated when the personal solar UVR exposure (PE) is known. During the past decades, a variety of studies was conducted to measure PE of outdoor workers and our knowledge on the PE of outdoor workers has remarkably increased. As shown by this review, studies clearly indicate that PE of most of outdoor workers exceeds the internationally proposed threshold limit value, which is comparable to 1.0 to 1.3 SED, respectively to 1.1 to 1.5 UV Index received over one hour. Besides working in a high UVR environment, monotonic workflow (limited movement, nearly static posture) is a risk factor. In such cases, PE can be higher than ambient UVR. In this review, we provide also a list of milestone, depicting the progress and the most important findings in this field during the past 45 years. However, in many respects our knowledge is still rudimentary, because of several reasons. Different measuring positions have been used so that measured PE is not comparable. Few studies were designed to enable extension of measured PE to other locations or dates. Although the importance of a proper calibration of the measuring devices in respect to the changing solar spectrum was pointed out from the beginning, this is often not performed, which leads to high uncertainties in the presented PE levels. At the end of our review, we provide some key points, which can be used to evaluate the quality of a study respectively to support the design of future studies
- …