6 research outputs found

    Etched track detector methods for the identification of target nuclear fragments in cosmic radiation and accelerator proton beams

    No full text
    In this article, two etched track detector methods for measuring short-range particles are presented and compared. The primary method employs observations of the evolution of the track geometry in intermittent etching, with the use of the appropriate track scanning procedures. The alternative method requires one-step etching and a specific analysis of the track parameters. Both methods proved to be effective in identifying target nuclear fragments amongst a high background from primary cosmic radiation. Additionally, the linear energy transfer (LET) spectrum of the target nuclear fragments, obtained onboard the International Space Station, was found to be consistent with the results from high-energy proton beams in ground-based experiments

    Verification of shielding effect by the water-filled materials for space radiation in the International Space Station using passive dosimeters

    No full text
    The dose reduction effects for space radiation by installation of water shielding material (“protective curtain”) of a stack board consisting of the hygienic wipes and towels have been experimentally evaluated in the International Space Station by using passive dosimeters. The averaged water thickness of the protective curtain was 6.3 g/cm2. The passive dosimeters consisted of a combination of thermoluminescent detectors (TLDs) and plastic nuclear track detectors (PNTDs). Totally 12 passive dosimeter packages were installed in the Russian Service Module during late 2010. Half of the packages were located at the protective curtain surface and the other half were at the crew cabin wall behind or aside the protective curtain. The mean absorbed dose and dose equivalent rates are measured to be 327 uGy/day and 821 uSv/day for the unprotected packages and 224 uGy/day and 575 uSv/day for the protected packages, respectively. The observed dose reduction rate with protective curtain was found to be 37 ± 7% in dose equivalent, which was consistent with the calculation in the spherical water phantom by PHITS. The contributions due to low and high LET particles were found to be comparable in observed dose reduction rate. The protective curtain would be effective shielding material for not only trapped particles (several 10 MeV) but also for low energy galactic cosmic rays (several 100 MeV/n). The properly utilized protective curtain will effectively reduce the radiation dose for crew living in space station and prolong long-term mission in the future

    Galactic cosmic ray simulation at the NASA Space Radiation Laboratory

    No full text
    Most accelerator-based space radiation experiments have been performed with single ion beams at fixed energies. However, the space radiation environment consists of a wide variety of ion species with a continuous range of energies. Due to recent developments in beam switching technology implemented at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL), it is now possible to rapidly switch ion species and energies, allowing for the possibility to more realistically simulate the actual radiation environment found in space. The present paper discusses a variety of issues related to implementation of galactic cosmic ray (GCR) simulation at NSRL, especially for experiments in radiobiology. Advantages and disadvantages of different approaches to developing a GCR simulator are presented. In addition, issues common to both GCR simulation and single beam experiments are compared to issues unique to GCR simulation studies. A set of conclusions is presented as well as a discussion of the technical implementation of GCR simulation
    corecore