35 research outputs found
Advanced experimental applications for x-ray transmission gratings Spectroscopy using a novel grating fabrication method
A novel fabrication method for soft x-ray transmission grating and other
optical elements is presented. The method uses Focused-Ion-Beam (FIB)
technology to fabricate high-quality free standing grating bars on Transmission
Electron Microscopy grids (TEM-grid). High quality transmission gratings are
obtained with superb accuracy and versatility. Using these gratings and
back-illuminated CCD camera, absolutely calibrated x-ray spectra can be
acquired for soft x-ray source diagnostics in the 100-3000 eV spectral range.
Double grating combinations of identical or different parameters are easily
fabricated, allowing advanced one-shot application of transmission grating
spectroscopy. These applications include spectroscopy with different spectral
resolutions, bandwidths, dynamic ranges, and may serve for identification of
high-order contribution, and spectral calibrations of various x-ray optical
elements
Measurement of L-shell emission from mid-Z targets under non-LTE conditions using Transmission Grating Spectrometer and DANTE power diagnostics
Producción CientíficaIn this work, we present the measurement of L-band emission from buried Sc/V targets in experiments performed at the OMEGA laser facility. The goal of these experiments was to study non-local thermodynamic equilibrium plasmas and benchmark atomic physics codes. The L-band emission was measured simultaneously by the time resolved DANTE power diagnostic and the recently fielded time integrated Soreq-Transmission Grating Spectrometer (TGS) diagnostic. The TGS measurement was used to support the spectral reconstruction process needed for the unfolding of the DANTE data. The Soreq-TGS diagnostic allows for broadband spectral measurement in the 120 eV–2000 eV spectral band, covering L- and M-shell emission of mid- and high-Z elements, with spectral resolution λ/Δλ = 8–30 and accuracy better than 25%. The Soreq-TGS diagnostic is compatible with ten-inch-manipulator platforms and can be used for a wide variety of high energy density physics, laboratory astrophysics, and inertial confinement fusion experiments
Principles of strategic drug delivery to the brain (SDDB): Development of anorectic and orexigenic analogs of leptin
The blood-brain barrier (BBB) presents a tremendous challenge for the delivery of drugs to the central nervous system (CNS). This includes drugs that target brain receptors for the treatment of obesity and anorexia. Strategic drug delivery to brain (SDDB) is an approach that considers in depth the relations among the BBB, the candidate therapeutic, the CNS target, and the disease state to be treated. Here, we illustrate principles of SDDB with two different approaches to developing drugs based on leptin. In normal body weight humans and in non-obese rodents, leptin is readily transported across the BBB and into the CNS where it inhibits feeding and enhances thermogenesis. However, in obesity, the transport of leptin across the BBB is impaired, resulting in a resistance to leptin. As a result, it is difficult to treat obesity with leptin or its analogs that depend on the leptin transporter for access to the CNS. To treat obesity, we developed a leptin agonist modified by the addition of pluronic block copolymers (P85-leptin). P85-leptin retains biological activity and is capable of crossing the BBB by a mechanism that is not dependent on the leptin transporter. As such, P85-leptin is able to cross the BBB of obese mice at a rate similar to that of native leptin in lean mice. To treat anorexia, we developed a leptin antagonist modified by pegylation (PEG-MLA) that acts primarily by blocking the BBB transporter for endogenous, circulating leptin. This prevents blood-borne, endogenous leptin from entering the CNS, essentially mimicking the leptin resistance seen in obesity, and resulting in a significant increase in adiposity. These examples illustrate two strategies in which an understanding of the interactions among the BBB, CNS targets, and candidate therapeutics under physiologic and diseased conditions can be used to develop drugs effective for the treatment of brain disease
Tumour expression of leptin is associated with chemotherapy resistance and therapy-independent prognosis in gastro-oesophageal adenocarcinomas
Background: Cytotoxic chemotherapy remains the main systemic therapy for gastro-oesophageal adenocarcinoma, but resistance to chemotherapy is common, resulting in ineffective and often toxic treatment for patients. Predictive biomarkers for chemotherapy response would increase the probability of successful therapy, but none are currently recommended for clinical use. We used global gene expression profiling of tumour biopsies to identify novel predictive biomarkers for cytotoxic chemotherapy. Methods: Tumour biopsies from patients (n=14) with TNM stage IB–IV gastro-oesophageal adenocarcinomas receiving platinum-based combination chemotherapy were used as a discovery cohort and profiled with Affymetrix ST1.0 Exon Genechips. An independent cohort of patients (n=154) treated with surgery with or without neoadjuvant platinum combination chemotherapy and gastric adenocarcinoma cell lines (n=22) were used for qualification of gene expression profiling results by immunohistochemistry. A cisplatin-resistant gastric cancer cell line, AGS Cis5, and the oesophageal adenocarcinoma cell line, OE33, were used for in vitro validation investigations. Results: We identified 520 genes with differential expression (Mann–Whitney U, P<0.020) between radiological responding and nonresponding patients. Gene enrichment analysis (DAVID v6.7) was used on this list of 520 genes to identify pathways associated with response and identified the adipocytokine signalling pathway, with higher leptin mRNA associated with lack of radiological response (P=0.011). Similarly, in the independent cohort (n=154), higher leptin protein expression by immunohistochemistry in the tumour cells was associated with lack of histopathological response (P=0.007). Higher leptin protein expression by immunohistochemistry was also associated with improved survival in the absence of neoadjuvant chemotherapy, and patients with low leptin protein-expressing tumours had improved survival when treated by neoadjuvant chemotherapy (P for interaction=0.038). In the gastric adenocarcinoma cell lines, higher leptin protein expression was associated with resistance to cisplatin (P=0.008), but not to oxaliplatin (P=0.988) or 5fluorouracil (P=0.636). The leptin receptor antagonist SHLA increased the sensitivity of AGS Cis5 and OE33 cell lines to cisplatin. Conclusions: In gastro-oesophageal adenocarcinomas, tumour leptin expression is associated with chemoresistance but a better therapy-independent prognosis. Tumour leptin expression determined by immunohistochemistry has potential utility as a predictive marker of resistance to cytotoxic chemotherapy, and a prognostic marker independent of therapy in gastro-oesophageal adenocarcinoma. Leptin antagonists have been developed for clinical use and leptin and its associated pathways may also provide much needed novel therapeutic targets for gastro-oesophageal adenocarcinoma
Recommended from our members
Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors.
The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 1011 sr-1 J-1 protons and carbons, (1.3 ± 0.7) × 108 sr-1 J-1 alpha particles from laser-driven proton-boron fusion reactions
Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors
Abstract The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 1011 sr−1 J−1 protons and carbons, (1.3 ± 0.7) × 108 sr−1 J−1 alpha particles from laser-driven proton-boron fusion reactions