46 research outputs found

    GG: A domain involved in phage LTF apparatus and implicated in human MEB and non-syndromic hearing loss diseases

    Get PDF
    AbstractHere, we report the identification of a novel domain – GG (domain in KIAA1199, FAM3, POMGnT1 and Tmem2 proteins, with two well-conserved glycine residues), present in eukaryotic FAM3 superfamily (FAM3A, FAM3B, FAM3C and FAM3D), POMGnT1 (protein O-linked mannose β-1,2-N-acetylglucosaminyltransferase), TEM2 proteins as well as phage gp35 proteins. GG domain has been revealed to be implicated in muscle–eye–brain disease and non-syndromic hearing loss. The presence of GG domain in Bacteriophage gp35 hinge connector of long tail fiber might reflect the horizontal gene transfer from organisms. And we proposed that GG domain might function as important structural element in phage LTF

    Compact source of narrowband and tunable X-rays for radiography

    Get PDF
    We discuss the development of a compact X-ray source based on inverse-Compton scattering with a laser-driven electron beam. This source produces a beam of high-energy X-rays in a narrow cone angle (5–10 mrad), at a rate of 108 photons-s_1. Tunable operation of the source over a large energy range, with energy spread of ~50%, has also been demonstrated. Photon energies \u3e10 MeV have been obtained. The narrowband nature of the source is advantageous for radiography with low dose, low noise, and minimal shielding

    Analysis of COVID-19 Guideline Quality and Change of Recommendations: A Systematic Review.

    Get PDF
    Background Hundreds of coronavirus disease 2019 (COVID-19) clinical practice guidelines (CPGs) and expert consensus statements have been developed and published since the outbreak of the epidemic. However, these CPGs are of widely variable quality. So, this review is aimed at systematically evaluating the methodological and reporting qualities of COVID-19 CPGs, exploring factors that may influence their quality, and analyzing the change of recommendations in CPGs with evidence published. Methods We searched five electronic databases and five websites from 1 January to 31 December 2020 to retrieve all COVID-19 CPGs. The assessment of the methodological and reporting qualities of CPGs was performed using the AGREE II instrument and RIGHT checklist. Recommendations and evidence used to make recommendations in the CPGs regarding some treatments for COVID-19 (remdesivir, glucocorticoids, hydroxychloroquine/chloroquine, interferon, and lopinavir-ritonavir) were also systematically assessed. And the statistical inference was performed to identify factors associated with the quality of CPGs. Results We included a total of 92 COVID-19 CPGs developed by 19 countries. Overall, the RIGHT checklist reporting rate of COVID-19 CPGs was 33.0%, and the AGREE II domain score was 30.4%. The overall methodological and reporting qualities of COVID-19 CPGs gradually improved during the year 2020. Factors associated with high methodological and reporting qualities included the evidence-based development process, management of conflicts of interest, and use of established rating systems to assess the quality of evidence and strength of recommendations. The recommendations of only seven (7.6%) CPGs were informed by a systematic review of evidence, and these seven CPGs have relatively high methodological and reporting qualities, in which six of them fully meet the Institute of Medicine (IOM) criteria of guidelines. Besides, a rapid advice CPG developed by the World Health Organization (WHO) of the seven CPGs got the highest overall scores in methodological (72.8%) and reporting qualities (83.8%). Many CPGs covered the same clinical questions (it refers to the clinical questions on the effectiveness of treatments of remdesivir, glucocorticoids, hydroxychloroquine/chloroquine, interferon, and lopinavir-ritonavir in COVID-19 patients) and were published by different countries or organizations. Although randomized controlled trials and systematic reviews on the effectiveness of treatments of remdesivir, glucocorticoids, hydroxychloroquine/chloroquine, interferon, and lopinavir-ritonavir for patients with COVID-19 have been published, the recommendations on those treatments still varied greatly across COVID-19 CPGs published in different countries or regions, which may suggest that the CPGs do not make sufficient use of the latest evidence. Conclusions Both the methodological and reporting qualities of COVID-19 CPGs increased over time, but there is still room for further improvement. The lack of effective use of available evidence and management of conflicts of interest were the main reasons for the low quality of the CPGs. The use of formal rating systems for the quality of evidence and strength of recommendations may help to improve the quality of CPGs in the context of the COVID-19 pandemic. During the pandemic, we suggest developing a living guideline of which recommendations are supported by a systematic review for it can facilitate the timely translation of the latest research findings to clinical practice. We also suggest that CPG developers should register the guidelines in a registration platform at the beginning for it can reduce duplication development of guidelines on the same clinical question, increase the transparency of the development process, and promote cooperation among guideline developers all over the world. Since the International Practice Guideline Registry Platform has been created, developers could register guidelines prospectively and internationally on this platform

    Adaptive-feedback spectral-phase control for interactions with transform-limited ultrashort high-power laser pulses

    Get PDF
    laser in vacuum. The spectral-phase distortion induced by the dispersion mismatching between the stretcher, compressor, and dispersive materials was fully compensated for by means of an adaptive closed-loop. The coherent temporal contrast on the sub-picosecond time scale was two orders of magnitude higher than that without adaptive control. This novel phase control capability enabled the experimental study of the dependence of laser wakefield acceleration on the spectral phase of intense laser ligh

    Generation of 9 MeV γ-rays by all-laser-driven Compton scattering with second-harmonic laser light

    Get PDF
    Gamma-ray photons with energy \u3e9 MeV were produced when second-harmonic-generated laser light (3 eV) inverse-Compton-scattered from a counterpropagating relativistic (∼450 MeV) laser-wakefield-accelerated electron beam. Two laser pulses from the same laser system were used: one to accelerate electrons and one to scatter. Since the two pulses play very different roles in the γ-ray generation process, and thus have different requirements, a novel laser system was developed. It separately and independently optimized the optical properties of the two pulses. This approach also mitigated the deleterious effects on beam focusing that generally accompany nonlinear optics at high peak-power levels

    Wavefront-correction for nearly diffraction limited focusing of dual-color laser beams to high intensities

    Get PDF
    We demonstrate wavefront correction of terawatt-peak-power laser beams at two distinct and well-separated wavelengths. Simultaneous near diffraction-limited focusability is achieved for both the fundamental (800 nm) and second harmonic (400 nm) of Ti:sapphire-amplified laser light. By comparing the relative effectiveness of various correction loops, the optimal ones are found. Simultaneous correction of both beams of different color relies on the linear proportionality between their wavefront aberrations. This method can enable two-color experiments at relativistic intensities

    Tomographic imaging of nonsymmetric multicomponent tailored supersonic flows from structured gas nozzles

    Get PDF
    We report experimental results on the production and characterization of asymmetric and composite supersonic gas flows, created by merging independently controllable flows from multiple nozzles. We demonstrate that the spatial profiles are adjustable over a large range of parameters, including gas density, density gradient, and atomic composition. The profiles were precisely characterized using three-dimensional tomography. The creation and measurement of complex gas flows is relevant to numerous applications, ranging from laser-produced plasmas to rocket thrusters

    Electron Trapping from Interactions between Laser-Driven Relativistic Plasma Waves

    Get PDF
    Interactions of large-amplitude relativistic plasma waves were investigated experimentally by propagating two synchronized ultraintense femtosecond laser pulses in plasma at oblique crossing angles to each other. The electrostatic and electromagnetic fields of the colliding waves acted to preaccelerate and trap electrons via previously predicted, but untested injection mechanisms of ponderomotive drift and wakewake interference. High-quality energetic electron beams were produced, also revealing valuable new information about plasma-wave dynamics
    corecore