60 research outputs found

    Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens

    Get PDF
    The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from −20 to −1100 V/mm for Ekin = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for Ekin = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at Ekin = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH reveal that the width of the Fermi edge increases by just 30 meV at an incident pump fluence of 22 mJ/cm2 (retarding field −21 V/mm). For an accelerating field of +2 kV/mm and a pump fluence of only 5 mJ/cm2, it increases by 0.5 eV (pump wavelength 1030 nm). At the given conditions, the suppression mode permits increasing the slow-electron yield by three to four orders of magnitude. The feasibility of the method at high energies is demonstrated without a pump beam at Ekin = 3830 eV using hard x rays from the storage ring PETRA III. The approach opens up a previously inaccessible regime of pump fluences for photoemission experiments

    Ultrafast manipulation of the NiO antiferromagnetic order via sub gap optical excitation

    Get PDF
    Wide band gap insulators such as NiO offer the exciting prospect of coherently manipulating electronic correlations with strong optical fields. Contrary to metals where rapid dephasing of optical excitation via electronic processes occurs, the sub gap excitation in charge transfer insulators has been shown to couple to low energy bosonic excitations. However, it is currently unknown if the bosonic dressing field is composed of phonons or magnons. Here we use the prototypical charge transfer insulator NiO to demonstrate that 1.5 eV sub gap optical excitation leads to a renormalised NiO band gap in combination with a significant reduction of the antiferromagnetic order. We employ element specific X ray reflectivity at the FLASH free electron laser to demonstrate the reduction of the upper band edge at the O 1s 2p core valence resonance K edge whereas the antiferromagnetic order is probed via X ray magnetic linear dichroism XMLD at the Ni 2p 3d resonance L2 edge . Comparing the transient XMLD spectral line shape to ground state measurements allows us to extract a spin temperature rise of 65 5 K for time delays longer than 400 fs while at earlier times a non equilibrium spin state is formed. We identify transient mid gap states being formed during the first 200 fs accompanied by a band gap reduction lasting at least up to the maximum measured time delay of 2.4 ps. Electronic structure calculations indicate that magnon excitations significantly contribute to the reduction of the NiO band ga

    Polymeric Micelles in Anticancer Therapy: Targeting, Imaging and Triggered Release

    Get PDF
    Micelles are colloidal particles with a size around 5–100 nm which are currently under investigation as carriers for hydrophobic drugs in anticancer therapy. Currently, five micellar formulations for anticancer therapy are under clinical evaluation, of which Genexol-PM has been FDA approved for use in patients with breast cancer. Micelle-based drug delivery, however, can be improved in different ways. Targeting ligands can be attached to the micelles which specifically recognize and bind to receptors overexpressed in tumor cells, and chelation or incorporation of imaging moieties enables tracking micelles in vivo for biodistribution studies. Moreover, pH-, thermo-, ultrasound-, or light-sensitive block copolymers allow for controlled micelle dissociation and triggered drug release. The combination of these approaches will further improve specificity and efficacy of micelle-based drug delivery and brings the development of a ‘magic bullet’ a major step forward

    Mesostructured Block Copolymer Nanoparticles: Versatile Templates for Hybrid Inorganic/Organic Nanostructures

    Get PDF
    We present a versatile strategy to prepare a range of nanostructured poly(styrene)-block-poly(2-vinyl pyridine) copolymer particles with tunable interior morphology and controlled size by a simple solvent exchange procedure. A key feature of this strategy is the use of functional block copolymers incorporating reactive pyridyl moieties which allow the absorption of metal salts and other inorganic precursors to be directed. Upon reduction of the metal salts, well-defined hybrid metal nanoparticle arrays could be prepared, whereas the use of oxide precursors followed by calcination permits the synthesis of silica and titania particles. In both cases, ordered morphologies templated by the original block copolymer domains were obtained

    EFFECT OF HPA BACK-OFF AND FILTER LENGTH ON 256QAM

    No full text

    Does adding clinical data to administrative data improve agreement among hospital quality measures?

    No full text
    BACKGROUND: Hospital performance measures based on patient mortality and readmission have indicated modest rates of agreement. We examined if combining clinical data on laboratory tests and vital signs with administrative data leads to improved agreement with each other, and with other measures of hospital performance in the nation\u27s largest integrated health care system. METHODS: We used patient-level administrative and clinical data, and hospital-level data on quality indicators, for 2007-2010 from the Veterans Health Administration (VA). For patients admitted for acute myocardial infarction (AMI), heart failure (HF) and pneumonia we examined changes in hospital performance on 30-d mortality and 30-d readmission rates as a result of adding clinical data to administrative data. We evaluated whether this enhancement yielded improved measures of hospital quality, based on concordance with other hospital quality indicators. RESULTS: For 30-d mortality, data enhancement improved model performance, and significantly changed hospital performance profiles; for 30-d readmission, the impact was modest. Concordance between enhanced measures of both outcomes, and with other hospital quality measures - including Joint Commission process measures, VA Surgical Quality Improvement Program (VASQIP) mortality and morbidity, and case volume - remained poor. CONCLUSIONS: Adding laboratory tests and vital signs to measure hospital performance on mortality and readmission did not improve the poor rates of agreement across hospital quality indicators in the VA. INTERPRETATION: Efforts to improve risk adjustment models should continue; however, evidence of validation should precede their use as reliable measures of quality

    Suppression of the vacuum space-charge effect in fs-photoemission by a retarding electrostatic front lens

    No full text
    The performance of time-resolved photoemission experiments at fs-pulsed photon sources is ultimately limited by the e–e Coulomb interaction, downgrading energy and momentum resolution. Here, we present an approach to effectively suppress space-charge artifacts in momentum microscopes and photoemission microscopes. A retarding electrostatic field generated by a special objective lens repels slow electrons, retaining the k-image of the fast photoelectrons. The suppression of space-charge effects scales with the ratio of the photoelectron velocities of fast and slow electrons. Fields in the range from −20 to −1100 V/mm for Ekin_{kin} = 100 eV to 4 keV direct secondaries and pump-induced slow electrons back to the sample surface. Ray tracing simulations reveal that this happens within the first 40 to 3 μm above the sample surface for Ekin_{kin} = 100 eV to 4 keV. An optimized front-lens design allows switching between the conventional accelerating and the new retarding mode. Time-resolved experiments at Ekin_{kin} = 107 eV using fs extreme ultraviolet probe pulses from the free-electron laser FLASH reveal that the width of the Fermi edge increases by just 30 meV at an incident pump fluence of 22 mJ/cm2^2 (retarding field −21 V/mm). For an accelerating field of +2 kV/mm and a pump fluence of only 5 mJ/cm2^2, it increases by 0.5 eV (pump wavelength 1030 nm). At the given conditions, the suppression mode permits increasing the slow-electron yield by three to four orders of magnitude. The feasibility of the method at high energies is demonstrated without a pump beam at Ekin_{kin} = 3830 eV using hard x rays from the storage ring PETRA III. The approach opens up a previously inaccessible regime of pump fluences for photoemission experiments
    corecore