13,834 research outputs found

    Studies in upper and lower atmosphere coupling

    Get PDF
    The theoretical and data-analytic work on upper and lower atmosphere coupling performed under a NASA Headquarters contract during the period April 1978 to March 1979 are summarized. As such, this report is primarily devoted to an overview of various studies published and to be published under this contract. Individual study reports are collected as exhibits. Work performed under the subject contract are in the following four areas of upper-lower atmosphere coupling: (1) Magnetosphere-ionosphere electrodynamic coupling in the aurora; (2) Troposphere-thermosphere coupling; (3) Ionosphere-neutral-atmosphere coupling; and (4) Planetary wave dynamics in the middle atmosphere

    Chloroquine-resistant Plasmodium falciparum malaria in the Kavango region of Namibia

    Get PDF
    The sensitivity to chloroquine of Plasmodium falciparum from the Kavango region of Namibia was determined by a 24-hour test in vitro. Twenty-six Isolates were successfully tested, of which 11 were resistant to a low degree, schizogony being inhibited at 8 pmollwell. The results of the Dill-Glazko test for the presence of 4-amlnoquinolines in urine indicate that chloroquine is not Widely used in the area

    Liver Transplantation for Advanced Liver Disease with Alpha-1antitrypsin Deficiency

    Get PDF
    ALPHA-1-antitrypsin deficiency associated with chronic obstructive airway disease was recognized in 1963 by Laurell and Ericksson.1 In 1969, Sharp2 described the first cases of alpha-1-antitrypsin-deficiency disease in children with cirrhosis. Since then, this inborn error has been recognized as one of the more common factors in cirrhosis of infancy and childhood,3 including “neonatal hepatitis.”4 Alpha-1-antitrypsin is a glycoprotein that accounts for a major portion of the alpha-1 globulin fraction of the serum.5 It is responsible for approximately 90 per cent of the antitrypsin activity6 of the serum, and it also inhibits several other plasma enzymes, including plasmin,7 elastase,8 collagenase,9 and. © 1980, Massachusetts Medical Society. All rights reserved

    Communications technology satellite output-tube design and development

    Get PDF
    The design and development of a 200-watt-output, traveling-wave tube (TWT) for the Communications Technology Satellite (CTS) is discussed, with emphasis on the design evolution during the manufacturing phase of the development program. Possible further improvements to the tube design are identified

    Initiatives to increase colonoscopy capacity - is there an impact on polyp detection? A UK National Endoscopy Database analysis

    Get PDF
    \ua9 2023 Georg Thieme Verlag. All rights reserved.Background Mismatch between routine endoscopy capacity and demand means centres often implement initiatives to increase capacity, such as weekend working or using locums/agency staff (insourcing). There are concerns about whether increasing workload to meet demand could negatively impact quality. We investigated polyp detection, a key quality metric, in weekend vs weekday and insourced vs standard procedures using data from the UK National Endoscopy Database (NED). Methods We conducted a national retrospective cross-sectional study of diagnostic colonoscopies undertaken 01/01-04/04/2019. The primary outcome was mean number of polyps (MNP) and the secondary, polyp detection rate (PDR). Multi-level mixed-effect regression, fitting endoscopist as a random effect, was used to examine associations between procedure day (weekend/weekday) and type (insourced/standard) and these outcomes, adjusting for patient age, sex and indication. Results 92,879 colonoscopies (weekends: 19,977 (21.5%); insourced: 9,909 (10.7%)) were performed by 2,496 endoscopists. For weekend colonoscopies, patients were more often female and less often having screening-related procedures; for insourced colonoscopies, patients were younger and less often attending for screening-related procedures (all p<0.05). Case-mix adjusted MNP was significantly lower for weekend vs weekday (IRR=0.86, (95%CI 0.83-0.89)) and for insourced vs standard procedures (IRR=0.91, (95%CI 0.87-0.95)). MNP was highest for weekday standard procedures and lowest for weekend insourced procedures, but there was no interaction between procedure day and type. Similar associations were found for PDR. Conclusions Strategies to increase colonoscopy capacity may have adverse effects on polyp detection. Routine quality monitoring should be undertaken following such initiatives. Meantime, reasons for this unwarranted variation require investigation

    Risk factors for failure of outpatient parenteral antibiotic therapy (OPAT) in infective endocarditis

    Get PDF
    Objectives: To identify risk factors for failure of outpatient antibiotic therapy (OPAT) in infective endocarditis (IE). Patients and methods: We identified IE cases managed at a single centre over 12 years from a prospectively maintained database. ‘OPAT failure’ was defined as unplanned readmission or antibiotic switch due to adverse drug reaction or antibiotic resistance. We analysed patient and disease-related risk factors for OPAT failure by univariate and multivariate logistic regression. We also retrospectively collected follow-up data on adverse disease outcome (defined as IE-related death or relapse) and performed Kaplan–Meier survival analysis up to 36 months following OPAT. Results: We identified 80 episodes of OPAT in IE. Failure occurred in 25/80 episodes (31.3%). On multivariate analysis, cardiac or renal failure [pooled OR 7.39 (95% CI 1.84–29.66), P = 0.005] and teicoplanin therapy [OR 8.69 (95% CI 2.01–37.47), P = 0.004] were independently associated with increased OPAT failure. OPAT failure with teicoplanin occurred despite therapeutic plasma levels. OPAT failure predicted adverse disease outcome up to 36 months (P = 0.016 log-rank test). Conclusions: These data caution against selecting patients with endocarditis for OPAT in the presence of cardiac or renal failure and suggest teicoplanin therapy may be associated with suboptimal OPAT outcomes. Alternative regimens to teicoplanin in the OPAT setting should be further investigated

    A mechanical, thermal and electrical packaging design for a prototype power management and control system for the 30 cm mercury ion thruster

    Get PDF
    A prototype electric power management and thruster control system for a 30 cm ion thruster is described. The system meets all of the requirements necessary to operate a thruster in a fully automatic mode. Power input to the system can vary over a full two to one dynamic range (200 to 400 V) for the solar array or other power source. The power management and control system is designed to protect the thruster, the flight system and itself from arcs and is fully compatible with standard spacecraft electronics. The system is easily integrated into flight systems which can operate over a thermal environment ranging from 0.3 to 5 AU. The complete power management and control system measures 45.7 cm (18 in.) x 15.2 cm (6 in.) x 114.8 cm (45.2 in.) and weighs 36.2 kg (79.7 lb). At full power the overall efficiency of the system is estimated to be 87.4 percent. Three systems are currently being built and a full schedule of environmental and electrical testing is planned

    Improved synchronous production of Plasmodium falciparum gametocytes in vitro.

    No full text
    The sexual stages of the Plasmodium falciparum life cycle are attractive targets for vaccines and transmission blocking drugs. Difficulties in culturing and obtaining large amounts of sexual stage P. falciparum parasites, particularly early stages, have often limited research progress in this area. We present a new protocol which simplifies the process of stimulating gametocytogenesis leading to improved synchronous gametocyte production. This new method can be adapted to enrich for early stage gametocytes (I and II) with a higher degree of purity than has previously been achieved, using MACS magnetic affinity columns. The protocol described lends itself to large scale culturing and harvesting of synchronous parasites suitable for biochemical assays, northern blots, flow cytometry, microarrays and proteomic analysis

    The swept angle retarding mass spectrometer: Initial results from the Michigan auroral probe sounding rocket

    Get PDF
    Data from a sounding rocket flight of the swept angle retarding ion mass spectrometer (SARIMS) are presented to demonstrate the capability of the instrument to make measurements of thermal ions which are differential in angle, energy, and mass. The SARIMS was flown on the Michigan auroral probe over regions characterized first by discrete auroral arcs and later by diffuse precipitation. The instrument measured the temperature, densities, and flow velocities of the ions NO(+) and O(+). Measured NO(+) densities ranged from 10 to the 5th power up to 3 x 10 to the 5th power ions/cu cm, while the measured O(+) densities were a factor of 5-10 less. Ion temperatures ranged from 0.15 up to 0.33 eV. Eastward ion flows approximately 0.5 km/sec were measured near the arcs, and the observed flow magnitude decreased markedly inside the arcs
    corecore