94 research outputs found

    Study the Effect of Imposing Surfactants toward the Evaporation of Low Molecular Weight Alcohol

    Get PDF
    In this paper, Reversed-Flow Gas Chromatography (RF-GC) is utilized to investigate the evaporation of low molecular weight alcohol. Evaporation rates as well as the diffusion rates of methanol are determined with a surfactant monolayer on the surface of the liquid; while nitrogen acts as carrier gas, at 313 K. The precision (>99.9) and accuracy of this investigation demonstrates the potential of current methodologies for environmental impact studies; this is further verified when the results are compared with the available literature. The varying evaporation rates of methanol in the presence of varying amounts of Triton X-100 reflects that application of surfactants do damper the evaporation rates of liquid pollutants; without interference with the former’s diffusion coefficients. High amounts of Triton X-100 are required for retardation of evaporation rates, suggesting the formation of a densely packed surface monolayer or the formation of an insoluble monolayer

    A Simple, Precise and Cost Effective PTFE Container Design Capable to Work in Domestic Microwave Oven

    Get PDF
    Starting from the first application of a microwave oven for sample preparation in 1975 for the purpose of wet ashing of biological samples using a domestic microwave oven, many microwave-assisted dissolution vessels have been developed. The advanced vessels are armed with special safety valve that release the excess of pressure while the vessels are in critical conditions due to applying high power of microwave. Nevertheless, this releasing of pressure may cause lose of volatile elements. In this study Teflon bottles are designed with relatively thicker wall compared to commercial ones and a silicone based polymer was used to prepare an O-ring which plays the role of safety valve. In this design, eight vessels are located in an ABS holder to keep them stable and safe. The advantage of these vessels is that they need only 2 mL of HNO3 and 1mL H2O2 to digest different environmental samples, namely, sludge, apple leave, peach leave, spinach leave and tomato leave. In order to investigate the performance of this design an ICP-MS instrument was applied for multi elemental analysis of 20 elements on the SRM of above environmental samples both using this design and a commercial microwave digestion design. Very comparable recoveries were obtained from this simple design with the commercial one. Considering the price of ultrapure chemicals and the amount of them which normally is about 8-10 mL, these simple vessels with the procedures that will be discussed in detail are very cost effective and very suitable for environmental studies

    A Simple, Precise and Cost Effective PTFE Container Design Capable to Work in Domestic Microwave Oven

    Get PDF
    Starting from the first application of a microwave oven for sample preparation in 1975 for the purpose of wet ashing of biological samples using a domestic microwave oven, many microwave-assisted dissolution vessels have been developed. The advanced vessels are armed with special safety valve that release the excess of pressure while the vessels are in critical conditions due to applying high power of microwave. Nevertheless, this releasing of pressure may cause lose of volatile elements. In this study Teflon bottles are designed with relatively thicker wall compared to commercial ones and a silicone based polymer was used to prepare an O-ring which plays the role of safety valve. In this design, eight vessels are located in an ABS holder to keep them stable and safe. The advantage of these vessels is that they need only 2 mL of HNO3 and 1mL H2O2 to digest different environmental samples, namely, sludge, apple leave, peach leave, spinach leave and tomato leave. In order to investigate the performance of this design an ICP-MS instrument was applied for multi elemental analysis of 20 elements on the SRM of above environmental samples both using this design and a commercial microwave digestion design. Very comparable recoveries were obtained from this simple design with the commercial one. Considering the price of ultrapure chemicals and the amount of them which normally is about 8-10 mL, these simple vessels with the procedures that will be discussed in detail are very cost effective and very suitable for environmental studies

    Spatial assessment of Langat river water quality using chemometrics

    Get PDF
    The present study deals with the assessment of Langat River water quality with some chemometrics approaches such as cluster and discriminant analysis coupled with an artificial neural network (ANN). The data used in this study were collected from seven monitoring stations under the river water quality monitoring program by the Department of Environment (DOE) from 1995 to 2002. Twenty three physico-chemical parameters were involved in this analysis. Cluster analysis successfully clustered the Langat River into three major clusters, namely high, moderate and less pollution regions. Discriminant analysis identified seven of the most significant parameters which contribute to the high variation of Langat River water quality, namely dissolved oxygen, biological oxygen demand, pH, ammoniacal nitrogen, chlorine, E. coli, and coliform. Discriminant analysis also plays an important role as an input selection parameter for an ANN of spatial prediction (pollution regions). The ANN showed better prediction performance in discriminating the regional area with an excellent percentage of correct classification compared to discriminant analysis. Multivariate analysis, coupled with ANN, is proposed, which could help in decision making and problem solving in the local environment

    A Simple, Precise and Cost Effective PTFE Container Design Capable to Work in Domestic Microwave Oven

    Get PDF
    Starting from the first application of a microwave oven for sample preparation in 1975 for the purpose of wet ashing of biological samples using a domestic microwave oven, many microwave-assisted dissolution vessels have been developed. The advanced vessels are armed with special safety valve that release the excess of pressure while the vessels are in critical conditions due to applying high power of microwave. Nevertheless, this releasing of pressure may cause lose of volatile elements. In this study Teflon bottles are designed with relatively thicker wall compared to commercial ones and a silicone based polymer was used to prepare an O-ring which plays the role of safety valve. In this design, eight vessels are located in an ABS holder to keep them stable and safe. The advantage of these vessels is that they need only 2 mL of HNO3 and 1mL H2O2 to digest different environmental samples, namely, sludge, apple leave, peach leave, spinach leave and tomato leave. In order to investigate the performance of this design an ICP-MS instrument was applied for multi elemental analysis of 20 elements on the SRM of above environmental samples both using this design and a commercial microwave digestion design. Very comparable recoveries were obtained from this simple design with the commercial one. Considering the price of ultrapure chemicals and the amount of them which normally is about 8-10 mL, these simple vessels with the procedures that will be discussed in detail are very cost effective and very suitable for environmental studies

    Sensitivity analysis for water quality index (WQI) prediction for Kinta River, Malaysia

    Get PDF
    Water quality index (WQI) serves as the basis for environment assessment of watercourse in relation to pollution load categorization and designation of classes and beneficial uses as provided by Interim National Water Quality Standards (INWQS) in Malaysia. This index is calculated based on six parameters DO, BOD, COD, pH, NH -NL and SS. This research was need as it will give the preliminary judgement on the importance 3 of each water quality parameter for WQI calculation at the Kinta River, Malaysia. This study revealed the used of sensitivity analysis based on ANN to evaluate the significant of each parameter for WQI determination. Sensitivity analysis was carried out for seven models (ANN-WQI-AP, ANN-WQI-LDO, ANN-WQI-LBOD, ANN-WQI-LCOD, ANN-WQI-LpH and ANN-WQI-LNH -NL) and a model performance criterion (R , RMSE and 3 2 SSE) was used for model performance evaluation. DO, SS and NH -NL were selected as the best input models 3 for WQI prediction. The ANN-WQI-LDO, ANN-WQI-LSS and ANN-WQI-LNH -NL model have R values of 3 2 0.8301, 0.9265 and 0.9369 respectively; RMSE values of 4.888, 3.214 and 2.978 respectively; SSE values of 3106.534, 1343.286 and 1152.902 respectively. The low R2 values and higher RMSE and SSE value compared to the ANN-WQI-AP model suggest the importance of these three parameters significantly affect the fitness and residual measurement of the ANN models in WQI prediction. The result also suggests that water quality of Kinta River was affected by agricultural activities and vicinity animal farm. Moreover the use of less parameter for WQI is much more applicable for our water resource management since its time and cost consuming

    Spatial variations of drinking water quality monitoring in water treatment plant using environmetric techniques

    Get PDF
    This research investigates the relationship between the physicochemical levels and the drinking water quality in Kuala Kubu Bharu, Selangor, Malaysia based on three different classes of drinking water. The environmetric techniques such as the discriminant analysis (DA), the principal component analysis (PCA) and the factor analysis (FA) were applied to analyze the spatial variation of the most significant physicochemical parameters of the drinking water quality and to determine the source of pollution. Seven physicochemical variables were analyzed. The forward and backward stepwise DA managed to discriminate six and two variables, respectively from the original seven variables. PCA and FA (varimax functionality) were to identify the origin of each water quality variable based on the three different drinking water classes. This study shows that environmetric method is the ideal way into provide meaningful information on the spatial variability of sophisticated drinking water quality data

    Chemometric Determination of the Geographical Origin of Milk Samples in Malaysia

    Get PDF
    In this work, Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Isotopic Ratio Mass Spectrometry (IRMS) and Ultrasound Milko Tester were used to study milk samples obtained from various geographical locations in Malaysia. ICP-MS was used to determine the concentration of trace elements in milk, water and soil samples obtained from seven dairy farms at different geographical locations in peninsular Malaysia. IRMS was used to analyze the milk samples for isotopic ratios of δ13C, 15N and 18O. Nutritional parameters in the milk samples were determined using an ultrasound milko tester. Data obtained from these measurements were evaluated by Principal Component Analysis (PCA) and Hierarchical Analysis (HA) as a preliminary step in determining geographical origin of these milk samples. It is observed that the isotopic ratios and a number of the nutritional parameters are responsible for the discrimination of the samples. It was also observed that it is possible to determine the geographical origin of these milk samples solely by the isotopic ratios of δ13C, 15N and 18O. The accuracy of the geographical discrimination is demonstrated when several milk samples from a milk factory taken from one of the regions under study were appropriately assigned to the correct PCA cluster

    Chemometric Determination of the Geographical Origin of Milk Samples in Malaysia

    Get PDF
    In this work, Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Isotopic Ratio Mass Spectrometry (IRMS) and Ultrasound Milko Tester were used to study milk samples obtained from various geographical locations in Malaysia. ICP-MS was used to determine the concentration of trace elements in milk, water and soil samples obtained from seven dairy farms at different geographical locations in peninsular Malaysia. IRMS was used to analyze the milk samples for isotopic ratios of δ13C, 15N and 18O. Nutritional parameters in the milk samples were determined using an ultrasound milko tester. Data obtained from these measurements were evaluated by Principal Component Analysis (PCA) and Hierarchical Analysis (HA) as a preliminary step in determining geographical origin of these milk samples. It is observed that the isotopic ratios and a number of the nutritional parameters are responsible for the discrimination of the samples. It was also observed that it is possible to determine the geographical origin of these milk samples solely by the isotopic ratios of δ13C, 15N and 18O. The accuracy of the geographical discrimination is demonstrated when several milk samples from a milk factory taken from one of the regions under study were appropriately assigned to the correct PCA cluster

    Chemometric Determination of the Geographical Origin of Milk Samples in Malaysia

    Get PDF
    In this work, Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Isotopic Ratio Mass Spectrometry (IRMS) and Ultrasound Milko Tester were used to study milk samples obtained from various geographical locations in Malaysia. ICP-MS was used to determine the concentration of trace elements in milk, water and soil samples obtained from seven dairy farms at different geographical locations in peninsular Malaysia. IRMS was used to analyze the milk samples for isotopic ratios of δ13C, 15N and 18O. Nutritional parameters in the milk samples were determined using an ultrasound milko tester. Data obtained from these measurements were evaluated by Principal Component Analysis (PCA) and Hierarchical Analysis (HA) as a preliminary step in determining geographical origin of these milk samples. It is observed that the isotopic ratios and a number of the nutritional parameters are responsible for the discrimination of the samples. It was also observed that it is possible to determine the geographical origin of these milk samples solely by the isotopic ratios of δ13C, 15N and 18O. The accuracy of the geographical discrimination is demonstrated when several milk samples from a milk factory taken from one of the regions under study were appropriately assigned to the correct PCA cluster
    corecore