26 research outputs found

    On the Question of Analyzing of the Iteratively Integrating Measurement Converter

    Get PDF
    Generalized structural scheme of the measurement converter which uses iteratively integrating conversion method is described. Analysis of its conversion equation and errors for the case where the input variable X = X (t) is not a constant, while the input values Z1, Z2 and output value Y are constant, was produced. Basic expressions for the calculation are listed

    Generalized Structural Scheme of the Measurement Converter Using an Iteratively Integrating Conversion Method

    Get PDF
    Generalized structural scheme of the measurement converter which uses iteratively integrating conversion method is described. Analysis of its conversion equation and errors was produced. Basic expressions for the calculation are listed. It is shown that the conversion equation for the steady state does not depend on the conversion coefficients of direct circuit blocks, which affect only a dynamic quality of converter that allows you to set low requirements to the said block at high precision converter as a whole

    Generalized Structural Scheme of the Measurement Converter Using an Iteratively Integrating Conversion Method

    Get PDF
    Generalized structural scheme of the measurement converter which uses iteratively integrating conversion method is described. Analysis of its conversion equation and errors was produced. Basic expressions for the calculation are listed. It is shown that the conversion equation for the steady state does not depend on the conversion coefficients of direct circuit blocks, which affect only a dynamic quality of converter that allows you to set low requirements to the said block at high precision converter as a whole

    Single-shot dynamics of dual-comb generation in a polarization-multiplexing fiber laser

    Get PDF
    Dual optical frequency combs have been a recurrent case of study over the last decade due to their wide use in a variety of metrology applications. Utilizing a single cavity laser to generate a dual comb reduces system complexity and facilitates suppression of common noise. However, a dual-comb regime in single cavity lasers tends to be more unstable and difficult to achieve. Therefore, having a better understanding about the way they are generated could improve and automate their generation and control. In this paper, we investigate the build-up dynamics and collision of dual comb in a polarization-multiplexing ring-cavity fiber laser using DFT (Dispersive Fourier Transform) method. We observe a bunch of meta-stable short-lived mode-locking states before the laser entered the dual-comb mode-locking state. The energy level of this short-lived initial pulses determines its evolution. If it decreases too much, the pulse will eventually collapse while if it stays above certain level, it will be successfully generated. The results presented in this paper increase the understanding of dual-comb generation inside a single cavity laser and may contribute in future attempts to increase the stabilization of this regime

    Predictors of Serum Dioxins and PCBs among Peripubertal Russian Boys

    Get PDF
    Background: Although sources and routes of exposure to dioxins and polychlorinated biphenyls (PCBs) have been studied, information regarding exposure among children is limited. Breast-feeding and diet are two important contributors to early life exposure. To further understand other significant contributors to childhood exposure, we studied a cohort of children from a city with high environmental dioxin levels. Objectives: We investigated predictors of serum concentrations of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs)/co-planar PCBs (C-PCBs), toxic equivalents (TEQs), and PCBs among 8- to 9-year-old boys in Chapaevsk, Russia. Methods: We used general linear regression models to explore associations of log10-transformed serum concentrations of PCDDs/PCDFs/C-PCBs, TEQs, and PCBs at study entry with anthropometric, demographic, geographic, and dietary factors in 482 boys in Chapaevsk, Russia. Results: The median (25th, 75th percentile) concentration for total 2005 TEQs was 21.1 pg/g lipid (14.4, 33.2). Boys who were older, consumed local foods, were breast-fed longer, and whose mothers were employed at the Khimprom chemical plant (where chlorinated chemicals were produced) or gardened locally had significantly higher serum dioxins and PCBs, whereas boys with higher body mass index or more educated parents had significantly lower serum dioxins and PCBs. Boys who lived less than 2 km from Khimprom had higher total TEQs (picograms per gram lipid) [adjusted mean = 30.6; 95% confidence interval (CI), 26.8–35.0] than boys who lived greater than 5 km away (adjusted mean = 18.8; 95% CI, 17.2–20.6). Conclusions: Our findings suggest that there are specific local sources of dioxin and PCB exposure among children in Chapaevsk including maternal gardening, consumption of locally grown food, and residential proximity to the Khimprom plant

    Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    Get PDF
    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%

    Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    Get PDF
    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS
    corecore