569 research outputs found

    Efficiency of Air Bubble Removal in Preparation of Low-Profile Angioplasty Balloon Catheter: Bench-Top Comparison of Six Methods

    Get PDF
    Purpose Complete removal of air bubbles from balloons for neurovascular angioplasty is cumbersome. We compared the preparation difficulty, air removal efficiency, and air collection pattern of six different balloon catheter preparation methods to propose a better preparation method for both initial and second balloon uses, especially for small-profile angioplasty balloon catheters.Materials and Methods A total of 18 neurovascular angioplasty balloon catheters with nominal diameters of 2 mm were prepared to test six different preparation methods: the instruction for use method (method A), simplified method using a syringe (method B) and four newly devised preparation methods using inflating devices (methods C–F). Serial radiographs were obtained while the balloons were gradually inflated. We measured the time for each preparation and the bubble number, analyzed their distribution in the balloon, and calculated the contrast filling ratio (contrast filling area/total balloon area) for initial and second ballooning. The whole process was repeated three times. Results The preparation time varied widely (11.5 seconds [method D] to 73.3 seconds [method A]). On initial inflation, the contrast filling ratio at 8 atm was the highest (100%) with methods A and F. On second inflation, the ratio was again highest with method A (99.5%), followed by method F (99.2%). Initial ballooning tended to show a uniform pattern of single bubble in the distal segment of the balloon; in contrast, second ballooning showed varying patterns in which the bubbles were multiple and randomly distributed. Conclusion None of the six methods were able to completely exclude air bubbles from the balloon catheters including the second ballooning; however, the method of repeating aspiration with high-volume inflating device (method F) could be a practical option considering the simplicity and efficiency of preparation

    Butterfly in the Esophagus: What Is Wrong?

    Get PDF

    Vascular effects of estrogen in type II diabetic postmenopausal women

    Get PDF
    AbstractOBJECTIVESWe assessed the effects of estrogen on vascular dilatory and other homeostatic functions potentially affected by nitric oxide (NO)-potentiating properties in type II diabetic postmenopausal women.BACKGROUNDThere is a higher cardiovascular risk in diabetic women than in nondiabetic women. This would suggest that women with diabetes do not have the cardioprotection associated with estrogen.METHODSWe administered placebo or conjugated equine estrogen, 0.625 mg/day for 8 weeks, to 20 type II diabetic postmenopausal women in a randomized, double-blinded, placebo-controlled, cross-over design.RESULTSCompared with placebo, estrogen tended to lower low-density lipoprotein (LDL) cholesterol levels by 15 ± 23% (p = 0.007) and increase high-density lipoprotein (HDL) cholesterol levels by 8 ± 16% (p = 0.034). Thus, the ratio of LDL to HDL cholesterol levels significantly decreased with estrogen, by 20 ± 24%, as compared with placebo (p = 0.001). Compared with placebo, estrogen tended to increase triglyceride levels by 16 ± 48% and lower glycosylated hemoglobin levels by 3 ± 13% (p = 0.295 and p = 0.199, respectively). However, estrogen did not significantly improve the percent flow-mediated dilatory response to hyperemia (17 ± 75% vs. placebo; p = 0.501). The statistical power to accept our observation was 81.5%. Compared with placebo, estrogen did not significantly change E-selectin, intercellular adhesion molecule-1, vascular cell adhesion molecule-1, monocyte chemoattractant protein-1 or matrix metalloproteinase-9 levels. Compared with placebo, estrogen tended to decrease tissue factor antigen and increase tissue factor activity levels by 7 ± 46% and 5 ± 34%, respectively (p = 0.321 and p = 0.117, respectively) and lower plasminogen activator inhibitor-1 levels by 16 ± 31% (p = 0.043).CONCLUSIONSThe effects of estrogen on endothelial, vascular dilatory and other homeostatic functions were less apparent in type II diabetic postmenopausal women, despite the beneficial effects of estrogen on lipoprotein levels

    Myxedema Ascites: Case Report and Literature Review

    Get PDF
    Myxedema ascites caused by hypothyroidism is rare, so its diagnosis is often delayed and patients frequently receive unnecessary procedures such as liver biopsies and exploratory laparotomies. We report a 71-yr-old man with clinical ascites that was the first manifestation of hypothyroidism, and which resolved completely in response to thyroid hormone replacement therapy. To our knowledge, this is the first report of myxedema ascites in Korea. A review of the literature revealed 51 well-documented cases of myxedema ascites. Analyses of ascites from patients in this condition usually show high protein (>2.5 g/dL) and low white blood cell counts, with a high proportion of lymphocytes. A consistent feature is the good response to thyroid hormone replacement therapy, which has always led to resolution of the ascites. Myxedema ascites is thus rare but easy to treat; it should be borne in mind, especially if the ascites fluid has a high protein content

    Nomogram to Predict Insignificant Prostate Cancer at Radical Prostatectomy in Korean Men: A Multi-Center Study

    Get PDF
    PURPOSE: Due to the availability of serum prostate specific antigen (PSA) testing, the detection rate of insignificant prostate cancer (IPC) is increasing. To ensure better treatment decisions, we developed a nomogram to predict the probability of IPC. MATERIALS AND METHODS: The study population consisted of 1,471 patients who were treated at multiple institutions by radical prostatectomy without neoadjuvant therapy from 1995 to 2008. We obtained nonrandom samples of n = 1,031 for nomogram development, leaving n = 440 for nomogram validation. IPC was defined as pathologic organ-confined disease and a tumor volume of 0.5 cc or less without Gleason grade 4 or 5. Multivariate logistic regression model (MLRM) coefficients were used to construct a nomogram to predict IPC from five variables, including serum prostate specific antigen, clinical stage, biopsy Gleason score, positive cores ratio and maximum % of tumor in any core. The performance characteristics were internally validated from 200 bootstrap resamples to reduce overfit bias. External validation was also performed in another cohort. RESULTS: Overall, 67 (6.5%) patients had a so-called "insignificant" tumor in nomogram development cohort. PSA, clinical stage, biopsy Gleason score, positive core ratio and maximum % of biopsy tumor represented significant predictors of the presence of IPC. The resulting nomogram had excellent discrimination accuracy, with a bootstrapped concordance index of 0.827. CONCLUSION: Our current nomogram provides sufficiently accurate information in clinical practice that may be useful to patients and clinicians when various treatment options for screen-detected prostate cancer are consideredope

    Clinical Significance of a Large Difference (≥ 2 points) between Biopsy and Post-prostatectomy Pathological Gleason Scores in Patients with Prostate Cancer

    Get PDF
    We investigated the clinical significance of large difference (≥ 2 points) between biopsy-derived (bGS) and post-prostatectomy Gleason scores (pGS). At 14 medical centers in Korea, 1,582 men who underwent radical prostatectomy for prostate cancer were included. According to the difference between bGS and pGS, the patients were divided into three groups: A (decreased in pGS ≥ 2, n = 30), B (changed in pGS ≤ 1, n = 1,361; control group), and C (increased in pGS ≥ 2, n = 55). We evaluated various clinicopathological factors of prostate cancer and hazards for biochemical failure. Group A showed significantly higher mean maximal percentage of cancer in the positive cores (max%) and pathological T stage than control. In group C, the number of biopsy core was significantly smaller, however, tumor volume and max% were significantly higher and more positive biopsy cores were presented than control. Worse pathological stage and more margin-positive were observed in group A and C than in control. Hazard ratio for biochemical failure was also higher in group A and C (P = 0.001). However, the groups were not independent factors in multivariate analysis. In conclusion, large difference between bGS and pGS shows poor prognosis even in the decreased group. However it is not an independent prognostic factor for biochemical failure

    Efficacies of the new Paclitaxel-eluting Coroflex Please™ Stent in percutaneous coronary intervention; comparison of efficacy between Coroflex Please™ and Taxus™ (ECO-PLEASANT) trial: study rationale and design

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Previous randomized trials have showed the superiority of Paclitaxel-eluting stent over bare metal stent in angiographic and clinical outcomes. Coroflex Please™ stent is a newly developed drug eluting stent using the Coroflex™ stent platform combined with the drug paclitaxel contained in a polymer coating. PECOPS I trial, one-arm observational study, showed that the clinical and angiographic outcomes of Coroflex Please™ stent were within the range of those of Taxus, the 1<sup>st </sup>generation paclitaxel-eluting stent (PES). However, there have been no studies directly comparing the Coroflex Please™ stent with the Taxus Liberte™ stent that is the newest version of Taxus. Therefore, prospective, randomized trial is required to demonstrate the non-inferiority of Coroflex Please™ stent compared with Taxus Liberte™ stent in a head-to-head manner.</p> <p>Methods</p> <p>In the comparison of Efficacy between COroflex PLEASe™ ANd Taxus™ stent(ECO-PLEASANT) trial, approximately 900 patients are being prospectively and randomly assigned to the either type of Coroflex Please™ stent and Taxus Liberte™ stent via web-based randomization. The primary endpoint is clinically driven target vessel revascularization at 9 months. The secondary endpoints include major cardiac adverse events, target vessel failure, stent thrombosis and angiographic efficacy endpoints.</p> <p>Discussion</p> <p>The ECO-PLEASANT trial is the study not yet performed to directly compare the efficacy and safety of the Coroflex Please™ versus Taxus Liberte™ stent. On the basis of this trial, we will be able to find out whether the Coroflex Please™ stent is non-inferior to Taxus Liberte™ stent or not.</p> <p>Trial registration</p> <p>ClinicalTrials.gov number, NCT00699543.</p

    Optimasi Portofolio Resiko Menggunakan Model Markowitz MVO Dikaitkan dengan Keterbatasan Manusia dalam Memprediksi Masa Depan dalam Perspektif Al-Qur`an

    Full text link
    Risk portfolio on modern finance has become increasingly technical, requiring the use of sophisticated mathematical tools in both research and practice. Since companies cannot insure themselves completely against risk, as human incompetence in predicting the future precisely that written in Al-Quran surah Luqman verse 34, they have to manage it to yield an optimal portfolio. The objective here is to minimize the variance among all portfolios, or alternatively, to maximize expected return among all portfolios that has at least a certain expected return. Furthermore, this study focuses on optimizing risk portfolio so called Markowitz MVO (Mean-Variance Optimization). Some theoretical frameworks for analysis are arithmetic mean, geometric mean, variance, covariance, linear programming, and quadratic programming. Moreover, finding a minimum variance portfolio produces a convex quadratic programming, that is minimizing the objective function ðð¥with constraintsð ð 𥠥 ðandð´ð¥ = ð. The outcome of this research is the solution of optimal risk portofolio in some investments that could be finished smoothly using MATLAB R2007b software together with its graphic analysis
    corecore