14 research outputs found

    Regulacija sile hidrauličke preše pomoću programa LabVIEW i uređaja NI-myRIO

    Get PDF
    U ovom završnom radu načinjen je eksperiment regulacije sile hidrauličke preše pomoću programa LabVIEW i uređaja NI myRIO. LabVIEW je grafički programski jezik namijenjen lakšem sakupljanju podataka iz ljudske okoline sa raznih instrumenata. Najčešće se koristi za prikupljanje, analizu i obradu podataka te kontrolu instrumenata i opreme. Programi rađeni pomoću LabVIEW alata nazivaju se Virtualni Instrumenti, skraćeno VI (engl. Virtual Instruments), jer njihov izgled i rad imitira stvarne instrumente. Svaki VI se sastoji od prednjeg panela i blok dijagrama. Prednji panel (engl. Front panel) namijenjen je za izradu grafičkog sučelja koji korisnik vidi kada je sustav pokrenut, a blok dijagram (engl. Block diagram) sadrži programske elemente preko kojih se odvija obrada podataka. S elektro-hidrauličkim servo sustavom povezan je uređaj NI myRIO na kojem se izvršava upravljački program za regulaciju sile hidrauličke preše primjenom servo ventila. NI myRIO je laboratorijski uređaj koji omogućuje izvršavanje algoritma u stvarnom realnom vremenu. Za vizualizaciju i nadzor rada elektro-hidrauličkog servo sustava koristi se prijenosno računalo na kojem se nalazi grafičko sučelje

    Microwave Annealing Effect for Highly Reliable Biosensor: Dual-Gate Ion-Sensitive Field-Effect Transistor Using Amorphous InGaZnO Thin-Film Transistor

    No full text
    We used a microwave annealing process to fabricate a highly reliable biosensor using amorphous-InGaZnO (a-IGZO) thin-film transistors (TFTs), which usually experience threshold voltage instability. Compared with furnace-annealed a-IGZO TFTs, the microwave-annealed devices showed superior threshold voltage stability and performance, including a high field-effect mobility of 9.51 cm<sup>2</sup>/V·s, a low threshold voltage of 0.99 V, a good subthreshold slope of 135 mV/dec, and an outstanding on/off current ratio of 1.18 × 10<sup>8</sup>. In conclusion, by using the microwave-annealed a-IGZO TFT as the transducer in an extended-gate ion-sensitive field-effect transistor biosensor, we developed a high-performance biosensor with excellent sensing properties in terms of pH sensitivity, reliability, and chemical stability

    DIC microscopy and retinal-section images with progress of RP (mice).

    No full text
    <p>The top-left image (A) shows the normal state of the photoreceptor layer, and the top-right image (B) shows a corresponding retinal section. (C) and (D) show the states aged 3 weeks, and E and F show the states aged 3 months. Morphological changes with RP progression were observed in both imaging modalities.</p

    Counting analysis (rats).

    No full text
    <p>(A) and (B) show original DIC images of the normal and progressed RP (5 weeks) states, respectively. (C) and (D) show counted cell boundaries analyzed by MATLAB using a morphological dilation and erosion algorithm. (E) and (F) show the combined images of original and analyzed images, which indicate well-matched positions.</p

    Additional file 1: Table S1. of High WT1 expression is an early predictor for relapse in patients with acute promyelocytic leukemia in first remission with negative PML-RARa after anthracycline-based chemotherapy: a single-center cohort study

    No full text
    Multivariate analysis in APL patients with CMR. Figure S1. Consort diagram of enrolled patients in this study. Underlined patients were excluded in this study (n=25). Abbreviation: APL, acute promyelocytic leukemia; ATRA, all-trans retinoic acid; CR, complete remission, CMR, complete molecular response; WT1, Wilms tumor 1. Figure S2. Comparison of PML-RARa and WT1 expression levels between relapsed and non-relapsed patients from diagnosis to relapse or 1 year after starting maintenance for non-relapsed patients. (DOCX 152 kb

    MOESM1 of Synaptonemal complex protein 3 is associated with lymphangiogenesis in non-small cell lung cancer patients with lymph node metastasis

    No full text
    Additional file 1: Figure S1. The histoscore distribution of SCP3, VEGF-A, VEGF-B, VEGF-C, and VEGF-D expression by quantitative image analysis. The cut-off values were defined by consideration of the distribution and prognostic significance of the value
    corecore