Recommended from our members
Building technolgies program. 1994 annual report
The objective of the Building Technologies program is to assist the U.S. building industry in achieving substantial reductions in building sector energy use and associated greenhouse gas emissions while improving comfort, amenity, health, and productivity in the building sector. We have focused our past efforts on two major building systems, windows and lighting, and on the simulation tools needed by researchers and designers to integrate the full range of energy efficiency solutions into achievable, cost-effective design solutions for new and existing buildings. In addition, we are now taking more of an integrated systems and life cycle perspective to create cost-effective solutions for more energy efficient, comfortable, and productive work and living environments. More than 30% of all energy use in buildings is attributable to two sources: windows and lighting. Together they account for annual consumer energy expenditures of more than $50 billion. Each affects not only energy use by other major building systems, but also comfort and productivity-factors that influence building economics far more than does direct energy consumption alone. Windows play a unique role in the building envelope, physically separating the conditioned space from the world outside without sacrificing vital visual contact. Throughout every space in a building, lighting systems facilitate a variety of tasks associated with a wide range of visual requirements while defining the luminous qualities of the indoor environment. Window and lighting systems are thus essential components of any comprehensive building science program
Recommended from our members
Energy performance analysis of prototype electrochromic windows
This paper presents the results of a study investigating the energy performance of three newly developed prototype electrochromic devices. The DOE-2.1 E energy simulation program was used to analyze the annual cooling, lighting, and total electric energy use and peak demand as a function of window type and size. The authors simulated a prototypical commercial office building module located in the cooling-dominated locations of Phoenix, AZ and Miami, FL. Heating energy use was also studied in the heating-dominated location of Madison, WI. Daylight illuminance was used to control electrochromic state-switching. Two types of window systems were analyzed; i.e., the outer pane electrochromic glazing was combined with either a conventional low-E or a spectrally selective inner pane. The properties of the electrochromic glazings are based on measured data of new prototypes developed as part of a cooperative DOE-industry program. The results show the largest difference in annual electric energy performance between the different window types occurs in Phoenix and is about 6.5 kWh/m{sup 2} floor area (0.60 kWh/ft{sup 2}) which can represent a cost of about .05/ft{sup 2}) using electricity costing $.08/kWh. In heating-dominated locations, the electrochromic should be maintained in its bleached state during the heating season to take advantage of beneficial solar heat gain which would reduce the amount of required heating. This also means that the electrochromic window with the largest solar heat gain coefficient is best
Recommended from our members
Advanced optical daylighting systems: light shelves and light pipes
We present two perimeter daylighting systems that passively redirect beam sunlight further from the window wall using special optical films, an optimized geometry, and a small glazing aperture. The objectives of these systems are (1) to increase daylight illuminance levels at 4.6-9.1 m (15-30 ft) from the window aperture with minimum solar heat gains and (2) to improve the uniformity of the daylighting luminance gradient across the room under variable solar conditions throughout the year. The designs were developed through a series of computer-assisted ray-tracing studies, laser visualization techniques, and photometric measurements and observations using physical scale models. Bi-directional illuminance measurements in combination with analytical routines were then used to simulate daylight performance for any solar position, and were incorporated into the DOE-2.1E building energy analysis computer program to evaluate energy savings. Results show increased daylight levels and an improved luminance gradient throughout the year compared to conventional daylighting systems
Recommended from our members
Advanced Interactive Facades - Critical Elements for Future GreenBuildings?
Building designers and owners have always been fascinated with the extensive use of glass in building envelopes. Today the highly glazed facade has almost become an iconic element for a 'green building' that provides daylighting and a visual connection with the natural environment. Even before the current interest in green buildings there was no shortage of highly glazed building designs. But many of these buildings either rejected sunlight, and some associated daylight and view with highly reflective glazings or used highly transmissive glass and encountered serious internal comfort problems that could only be overcome with large HVAC systems, resulting in significant energy, cost and environmental penalties. From the 1960's to the 1990's innovation in glazing made heat absorbing glass, reflective glass and double glazing commonplace, with an associated set of aesthetic features. In the last decade there has been a subtle shift from trying to optimize an ideal, static design solution using these glazings to making the facade responsive, interactive and even intelligent. More sophisticated design approaches and technologies have emerged using new high-performance glazing, improved shading and solar control systems, greater use of automated controls, and integration with other building systems. One relatively new architectural development is the double glass facade that offers a cavity that can provide improved acoustics, better solar control and enhanced ventilation. Taken to its ultimate development, an interactive facade should respond intelligently and reliably to the changing outdoor conditions and internal performance needs. It should exploit available natural energies for lighting, heating and ventilation, should be able to provide large energy savings compared to conventional technologies, and at the same time maintain optimal indoor visual and thermal comfort conditions. As photovoltaic costs decrease in the future, these onsite power systems will be integrated within the glass skin and these facades will become local, non-polluting energy suppliers to the building. The potential for facilitating sustainable building operations in the future by exploiting these concepts is therefore great. There is growing interest in highly glazed building facades, driven by a variety of architectural, aesthetic, business and environmental rationales. The environmental rationale appears plausible only if conventional glazing systems are replaced by a new generation of high performance, interactive, intelligent facade systems, that meet the comfort and performance needs of occupants while satisfying owner economic needs and broader societal environmental concerns. The challenge is that new technology, better systems integration using more capable design tools, and smarter building operation are all necessary to meet these goals. The opportunity is to create a new class of buildings that are both environmentally responsible at a regional or global level while providing the amenities and working environments that owners and occupants seek
Recommended from our members
The energy performance of electrochromic windows in heating-dominated geographic locations
This paper presents the results of a study investigating the energy performance of electrochromic windows in heating-dominated geographic locations under a variety of state-switching control strategies. The authors used the DOE-2.1E energy simulation program to analyze the annual heating, cooling and lighting energy use and performance as a function of glazing type, size, and electrochromic control strategy. They simulated a prototypical commercial office building module located in Madison, Wisconsin. Control strategies analyzed were based on daylight illuminance, incident total solar radiation, and space cooling load. The results show that overall energy performance is best if the electrochromic is left in its clear or bleached state during the heating season, but controlled during the cooling season using daylight illuminance as a control strategy. Even in such heating dominated locations as madison, there is still a well-defined cooling season when electrochromic switching will be beneficial. However, having the electrochromic remain in its bleached state during the winter season may result in glare and visual comfort problems for occupants much in the same way as conventional glazings
Recommended from our members
Office worker response to an automated venetian blind and electric lighting system: A pilot study
A prototype integrated, dynamic building envelope and lighting system designed to optimize daylight admission and solar heat gain rejection on a real-time basis in a commercial office building is evaluated. Office worker response to the system and occupant-based modifications to the control system are investigated to determine if the design and operation of the prototype system can be improved. Key findings from the study are: (1) the prototype integrated envelope and lighting system is ready for field testing, (2) most office workers (N=14) were satisfied with the system, and (3) there were few complaints. Additional studies are needed to explain how illuminance distribution, lighting quality, and room design can affect workplans illuminance preferences
The Effect of a Hip Strengthening Program on Mechanics during Running and Single Leg Squatting
STUDY DESIGN: Block randomized controlled trial. OBJECTIVES: To investigate whether a strengthening and movement education program, targeting the hip abductors and hip external rotators, alters hip mechanics during running and during a single-leg squat.
BACKGROUND:
Abnormal movement patterns during running and single-leg squatting have been associated with a number of running-related injuries in females. Therapeutic interventions for these aberrant movement patterns typically include hip strengthening. While these strengthening programs have been shown to improve symptoms, it is unknown if the underlying mechanics during functional movements is altered.
METHODS: Twenty healthy females with excessive hip adduction during running, as determined by instrumented gait analysis, were recruited. The runners were matched by age and running distance, and randomized to either a training group or a control group. The training group completed a hip strengthening and movement education program 3 times per week for 6 weeks in addition to single-leg squat training with neuromuscular reeducation consisting of mirror and verbal feedback on proper mechanics. The control group did not receive an intervention but maintained the current running distance. Using a handheld dynamometer and standard motion capture procedures, hip strength and running and single-leg squat mechanics were compared before and after the strengthening and movement education program. RESULTS: While hip abductor and external rotation strength increased significantly (P<.005) in the training group, there were no significant changes in hip or knee mechanics during running. However, during the single-leg squat, hip adduction, hip internal rotation, and contralateral pelvic drop all decreased significantly (P = .006, P = .006, and P = .02, respectively). The control group exhibited no changes in hip strength, nor in the single-leg squat or running mechanics at the conclusion of the 6-week study. CONCLUSION: A training program that included hip strengthening and movement training specific to single-leg squatting did not alter running mechanics but did improve single-leg squat mechanics. These results suggest that hip strengthening and movement training, when not specific to running, do not alter abnormal running mechanics. LEVEL OF EVIDENCE: Therapy, level 2b. NOTE: This is not the final published version. The final version was published in the Journal of Orthopaedic and Sports Physical Therapy. 2011 Sep; 41(9): 625-32. doi: 10.2519/jospt.2011.347
Recommended from our members
Visual quality assessment of electrochromic and conventional glazings
Variable transmission, ``switchable`` electrochromic glazings are compared to conventional static glazings using computer simulations to assess the daylighting quality of a commercial office environment where paper and computer tasks are performed. RADIANCE simulations were made for a west-facing commercial office space under clear and overcast sky conditions. This visualization tool was used to model different glazing types, to compute luminance and illuminance levels, and to generate a parametric set of photorealistic images of typical interior views at various times of the day and year. Privacy and visual display terminal (VDT) visibility is explored. Electrochromic glazings result in a more consistent glare-free daylit environment compared to their static counterparts. However, if the glazing is controlled to minimize glare or to maintain low interior daylight levels for critical visual tasks (e.g, VDT), occupants may object to the diminished quality of the outdoor view due to its low transmission (Tv = 0.08) during those hours. RADIANCE proved to be a very powerful tool to better understand some of the design tradeoffs of this emerging glazing technology. The ability to draw specific conclusions about the relative value of different technologies or control strategies is limited by the lack of agreed upon criteria or standards for lighting quality and visibility
Recommended from our members
Demonstration of a light-redirecting skylight system at the Palm Springs Chamber of Commerce
As part of a demonstration project to provide a comprehensive energy upgrade to a 294 m{sup 2} (3168 ft{sup 2}) commercial building, an advanced skylight design was developed using optical light control materials and geometry to provide daylight to two adjoining offices. The skylight system was developed using outdoor physical model tests and simulation tools Limited on-site measurements and occupant polls were conducted. Market issues were addressed. The skylight systems were found to improve lighting quality and to control excessive daylight illuminance levels compared to a conventional diffusing bubble skylight. Daylighting principles developed in earlier work for vertical glazing systems (light shelves and light pipes) were shown to be applicable in skylight designs at full-scale
Recommended from our members
The Building Design Advisor
The Building Design Advisor (BDA) is a software environment that supports the integrated use of multiple analysis and visualization tools throughout the building design process, from the initial, schematic design phases to the detailed specification of building components and systems. Based on a comprehensive design theory, the BDA uses an object-oriented representation of the building and its context, and acts as a data manager and process controller to allow building designers to quickly navigate through the multitude of descriptive and performance parameters addressed by the analysis and visualization tools linked to the BDA. Through the Browser the user can edit the values of input parameters and select any number of input and/or output parameters for display in the Decision Desktop. The Desktop allows building designers to compare multiple design alternatives with respect to any number of parameters addressed by the tools linked to the BDA
- …