132 research outputs found

    Long-term Performance and Community Analysis of Spirodela Polyrrhiza-bacteria Association Treating Phenol-contaminated Water

    Full text link
    『大阪大学大学院工学研究科環境・エネルギー工学専攻生物圏環境工学領域 研究活動報告』, (2010.4.1~2011.3.31), pp.83-94, 大阪大学大学院工学研究科環境・エネルギー工学専攻環境資源・材料学講座生物圏環境工学領域, 2011.5 に掲

    Dynamical structure factors of the magnetization-plateau state in the S=1/2S=1/2 bond-alternating spin chain with a next-nearest-neighbor interaction

    Full text link
    We calculate the dynamical structure factors of the magnetization-plateau state in the S=1/2S=1/2 bond-alternating spin chain with a next-nearest-neighbor interaction. The results show characteristic behaviors depending on the next-nearest-neighbor interaction α\alpha and the bond-alternation δ\delta. We discuss the lower excited states in comparison with the exact excitation spectrums of an effective Hamiltonian. From the finite size effects, characteristics of the lowest excited states are investigated. The dispersionless mode of the lowest excitation appears in adequate sets of α\alpha and δ\delta, indicating that the lowest excitation is localized spatially and forms an isolated mode below the excitation continuum. We further calculate the static structure factors. The largest intensity is located at q=πq=\pi for small δ\delta in fixed α\alpha. With increasing δ\delta, the wavenumber of the largest intensity shifts towards q=π/2q=\pi/2, taking the incommensurate value.Comment: to appear in Phys. Rev. B (2001

    Search for VHE gamma rays from SS433/W50 with the CANGAROO-II telescope

    Full text link
    SS433, located at the center of the supernova remnant W50, is a close proximity binary system consisting of a compact star and a normal star. Jets of material are directed outwards from the vicinity of the compact star symmetrically to the east and west. Non-thermal hard X-ray emission is detected from lobes lying on both sides. Shock accelerated electrons are expected to generate sub-TeV gamma rays through the inverse-Compton process in the lobes. Observations of the western X-ray lobe region of SS433/W50 system have been performed to detect sub-TeV gamma-rays using the 10m CANGAROO-II telescope in August and September, 2001, and July and September, 2002. The total observation times are 85.2 hours for ON source, and 80.8 hours for OFF source data. No significant excess of sub-TeV gamma rays has been found at 3 regions of the western X-ray lobe of SS433/W50 system. We have derived 99% confidence level upper limits to the fluxes of gamma rays and have set constraints on the strengths of the magnetic fields assuming the synchrotron/inverse-Compton model for the wide energy range of photon spectrum from radio to TeV. The derived lower limits are 4.3 microgauss for the center of the brightest X-ray emission region and 6.3 microgauss for the far end from SS433 in the western X-ray lobe. In addition, we suggest that the spot-like X-ray emission may provide a major contribution to the hardest X-ray spectrum in the lobe.Comment: 7 pages, 8 figures, to be published in Astroparticle Physic

    Detection of Gamma-rays around 1TeV from RX J0852.0-4622 by CANGAROO-II

    Full text link
    We have detected gamma-ray emission at the 6sigma level at energies greater than 500GeV from the supernova remnant RX J0852.0-4622 (G266.2-1.2) using the CANGAROO-II Imaging Atmospheric Cherenkov Telescope (IACT). The flux was 0.12 times of that of Crab at 1TeV. The signal centroid is consistent with the peak of the X-ray emission in the north-west rim of the remnant.Comment: 12pages, 4figures, to be published in ApJ

    Detection of diffuse TeV gamma-ray emission from the nearby starburst galaxy NGC 253

    Get PDF
    We report the TeV gamma-ray observations of the nearby normal spiral galaxy NGC 253. At a distance of \sim2.5 Mpc, NGC 253 is one of the nearest starburst galaxies. This relative closeness, coupled with the high star formation rate in the galaxy, make it a good candidate TeV gamma-ray source. Observations were carried out in 2000 and 2001 with the CANGAROO-II 10 m imaging atmospheric Cerenkov telescope. TeV gamma-ray emission is detected at the 11σ\sim 11\sigma level with a flux of (7.8±2.5)×1012cm2sec1(7.8 \pm 2.5)\times 10^{-12} {\rm cm}^{-2} {\rm sec}^{-1} at energies >>0.5 TeV. The data indicate that the emission region is broader than the point spread function of our telescope.Comment: 4 pages, double colomn, 3 figures, aa.cl

    Search for TeV gamma-rays from SN 1987A in 2001

    Full text link
    We searched for TeV gamma-rays from the remnant of SN 1987A around 5400 days after the supernova. The observations were carried out in 2001, from November 16 to December 11, using the CANGAROO-II Imaging Atmospheric Cherenkov Telescope. In total, 708 minutes of ON- and 1019 minutes of OFF-source data were obtained under good conditions. The detection threshold was estimated to be 1 TeV, due to the mean zenith angle of 39^\circ. The upper limits for the gamma-ray flux were obtained and compared with the previous observations and theoretical models. The observations indicate that the gamma-ray luminosity is lower than 1×10371\times 10^{37} erg s1^{-1} at 10\sim 10 TeV.Comment: 8 pages, 3 figures, submitted for publication, style file adde

    Evidence of TeV gamma-ray emission from the nearby starburst galaxy NGC 253

    Full text link
    TeV gamma-rays were recently detected from the nearby normal spiral galaxy NGC 253 (Itoh et al., 2002). Observations to detect the Cherenkov light images initiated by gamma-rays from the direction of NGC 253 were carried out in 2000 and 2001 over a total period of \sim150 hours. The orientation of images in gamma-ray--like events is not consistent with emission from a point source, and the emission region corresponds to a size greater than 10 kpc in radius. Here, detailed descriptions of the analysis procedures and techniques are given.Comment: 16 pages, 27 figures, aa.cl

    Asian-Specific total knee system: 5-14 year follow-up study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Knee size and body size differ in Asians compared with Caucasians. Nevertheless, many total knee arthroplasty (TKA) prostheses used worldwide are made for Western Caucasian subjects. As a result, an Asian's knee might not fit these prostheses. We studied the Flexible Nichidai Knee (FNK) system, a new model of TKA for Asian patients. The purpose of this report is to investigate the outcomes of this prosthesis retrospectively.</p> <p>Methods</p> <p>We investigated 1055 primary TKAs in 595 patients who underwent FNK for osteoarthritis (OA) in Japan and were followed for > 5 years. The knee score and function score were used for clinical evaluation. We examined the range of motion (ROM) preoperatively and at final follow-up and radiographic assessments. In addition, postoperative complications were investigated. A survivorship analysis was also conducted using two endpoints: revision for any reason and aseptic failure.</p> <p>Results</p> <p>890 knees in 502 patients were available for study (follow-up rate of 96.0%). The mean follow-up term was 8.3 years (range, 5.0-14.1 years). The knee and function score significantly improved from 41.3 to 90.3 and from 39.1 to 76.2 points, respectively (p < 0.001). The mean ROM in FNK posterior cruciate retaining (CR) type and FNK posterior-stabilized (PS) type ameliorated significantly from 107.8° and 95.6° to 110.7° and 110.4°, respectively (p < 0.01). Ten knees underwent revision surgery (infection in 3 cases, instability in 2, loosening in 2, and non-union of femoral supracondylar fracture, severe pain, and recurrent hemarthrosis in 1 each). The survivorship rate was 99.4% (95% CI, 99.0-99.8) at 5 years (n = 952 patients at risk) and 96.2% (95% CI, 91.9-100) at 12.5 years (n = 49 patients at risk).</p> <p>Conclusion</p> <p>The FNK prosthesis for Asians achieved excellent mid- to long-term survivorship and clinical results.</p

    Expression of chemokine receptors on peripheral blood lymphocytes in multiple sclerosis and neuromyelitis optica

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The role of different chemokine receptors in the pathogenesis of multiple sclerosis (MS) has been extensively investigated; however, little is known about the difference in the role of chemokine receptors between the pathogenesis of neuromyelitis optica (NMO) and MS. Therefore, we examined the expression of chemokine receptors on peripheral blood lymphocytes (PBL) in MS and NMO.</p> <p>Methods</p> <p>We used flow cytometry to analyse lymphocyte subsets in 12 patients with relapsing NMO, 24 with relapsing-remitting MS during relapse, 3 with NMO and 5 with MS during remission.</p> <p>Results</p> <p>Compared with healthy controls (HC), the percentage of lymphocytes in white blood cells was significantly lower in NMO and MS patients. The percentage of T cells expressing CD4<sup>+</sup>CD25<sup>+ </sup>and CD4<sup>+</sup>CD45RO<sup>+ </sup>was higher, while that of CD4<sup>+</sup>CC chemokine receptor (CCR)3<sup>+ </sup>(T helper 2, Th2) was significantly lower in MS patients than in HC. The ratios of CD4<sup>+</sup>CXC chemokine receptors (CXCR)3<sup>+</sup>/CD4<sup>+</sup>CCR3<sup>+ </sup>(Th1/Th2) and CD8<sup>+</sup>CXCR3<sup>+</sup>/CD8<sup>+</sup>CCR4<sup>+ </sup>(T cytotoxic 1, Tc1/Tc2) were higher in MS patients than in HC. The percentage of CD8<sup>+</sup>CXCR3<sup>+ </sup>T cell (Tc1) and CD4<sup>+</sup>CXCR3<sup>+ </sup>T cell (Th1) decreased significantly during remission in MS patients (<it>P <</it>0.05). No significant differences were identified in the expression of the chemokine receptors on PBL in NMO patients compared with MS patients and HC.</p> <p>Conclusions</p> <p>Th1 dominance of chemokine receptors on blood T cells and the correlation between CXCR3<sup>+ </sup>T cell (Th1 and Tc1) and disease activity in MS patients were confirmed by analysing chemokines receptors on PBL. In contrast, deviation in the Th1/Th2 balance was not observed in NMO patients.</p
    corecore