1,107 research outputs found
VUV-Vis optical characterization of Tetraphenyl-butadiene films on glass and specular reflector substrates from room to liquid Argon temperature
The use of efficient wavelength-shifters from the vacuum-ultraviolet to the
photosensor's range of sensitivity is a key feature in detectors for Dark
Matter search and neutrino physics based on liquid argon scintillation
detection. Thin film of Tetraphenyl-butadiene (TPB) deposited onto the surface
delimiting the active volume of the detector and/or onto the photosensor
optical window is the most common solution in current and planned experiments.
Detector design and response can be evaluated and correctly simulated only when
the properties of the optical system in use (TPB film + substrate) are fully
understood. Characterization of the optical system requires specific, sometimes
sophisticated optical methodologies. In this paper the main features of TPB
coatings on different, commonly used substrates is reported, as a result of two
independent campaigns of measurements at the specialized optical metrology labs
of ENEA and University of Tor Vergata. Measured features include TPB emission
spectra with lineshape and relative intensity variation recorded as a function
of the film thickness and for the first time down to LAr temperature, as well
as optical reflectance and transmittance spectra of the TPB coated substrates
in the wavelength range of the TPB emission
ASCA and BeppoSAX observations of the peculiar X-ray source 4U1700+24/HD154791
The X-ray source 4U1700+24/HD154791 is one of the few galactic sources whose
counterpart is an evolved M star. In X-rays the source shows extreme erratic
variability and a complex and variable spectrum. While this strongly suggests
accretion onto a compact object, no clear diagnosis of binarity was done up to
now. We report on ASCA and BeppoSAX X-ray broad band observations of this
source and on ground optical observations from the Loiano 1.5 m telescope.Comment: 5 pages, 4 figures, uses aipproc.sty, to appear in Proceedings of the
Fifth Compton Symposiu
Searching for supergiant fast X-ray transients with Swift
Supergiant fast X-ray transients (SFXTs) are high mass X-ray binaries (HMXBs)
hosting a neutron star and an OB supergiant companion. We examine the available
Swift data, as well as other new or archival/serendipitous data, on three
sources: IGR J17407-2808, 2XMM J185114.3-000004, and IGR J18175-2419, whose
X-ray characteristics qualify them as candidate SFXT, in order to explore their
properties and test whether they are consistent with an SFXT nature. As IGR
J17407-2808 and 2XMM J185114.3-000004 triggered the Burst Alert Telescope on
board Swift, the Swift data allow us to provide their first arcsecond
localisations, leading to an unequivocal identification of the source CXOU
J174042.0-280724 as the soft X-ray counterpart of IGR J17407-2808, as well as
their first broadband spectra, which can be fit with models generally
describing accreting neutron stars in HMXBs. While still lacking optical
spectroscopy to assess the spectral type of the companion, we propose 2XMM
J185114.3-000004 as a very strong SFXT candidate. The nature of IGR J17407-2808
remains, instead, more uncertain. Its broad band properties cannot exclude that
the emission originates from either a HMXB (and in that case, a SFXT) or, more
likely, a low mass X-ray binary. Finally, based on the deep non-detection in
our XRT monitoring campaign and a careful reanalysis of the original Integral
data in which the discovery of the source was first reported, we show that IGR
J18175-2419 is likely a spurious detection.Comment: Accepted for publication in Astronomy and Astrophysics. 12 pages, 11
figures, 6 table
Neutron to Gamma Pulse Shape Discrimination in Liquid Argon Detectors with High Quantum Effciency Photomultiplier Tubes
Abstract A high Light Yield Liquid Argon chamber has been radiated with an Am/Be source for signal-to-background separation level characterization in a Dark Matter Liquid Argon based detector. Apart from the standard nuclear recoil and electron events, from neutron elastic interactions and gamma conversions respectively, an intermediate population has been observed which is attributed to inelastic neutron scatters on Argon nuclei producing Argon recoil and simultaneous gammas from nuclear de-excitation. Taking account of these events results in a better determination of the recoil-like to electron-like separation based on the shape of the scintillation pulse. The results of this recent study as well as from a previous study with a chamber with a lower Light Yield are presented
IBIS/PICsIT in-flight performances
PICsIT (Pixellated Imaging CaeSium Iodide Telescope) is the high energy
detector of the IBIS telescope on-board the INTEGRAL satellite. PICsIT operates
in the gamma-ray energy range between 175 keV and 10 MeV, with a typical energy
resolution of 10% at 1 MeV, and an angular resolution of 12 arcmin within a
\~100 square degree field of view, with the possibility to locate intense point
sources in the MeV region at the few arcmin level. PICsIT is based upon a
modular array of 4096 independent CsI(Tl) pixels, ~0.70 cm^2 in cross-section
and 3 cm thick. In this work, the PICsIT on-board data handling and science
operative modes are described. This work presents the in-flight performances in
terms of background count spectra, sensitivity limit, and imaging capabilities.Comment: 8 pages, 4 figures. Accepted for publication on A&A, special issue on
First Science with INTEGRA
- …