135 research outputs found

    Beating-heart implantation of adjustable length mitral valve chordae: acute and chronic experience in an animal model

    Get PDF
    Objective: This study aimed to determine the acute and chronic performance of a new system designed to conduct beating-heart implantation and off-pump adjustment of neochordal length. Methods: In 14 adult sheep (group A) selected to undergo beating-heart cardiopulmonary bypass, the left atrium was opened through a left thoracotomy. Two or more primary chordae in the A2 region were severed to produce a model of a flail leaflet. A chordal adjustment mechanism (V-Chordal, Valtech Cardio Ltd., Or-Yehuda, Israel) was affixed to the head of the papillary muscle. The system includes two adjustable neochordae. The distal end of the neochordae was sutured to the flail segment without estimating the appropriate length. The neochordal length was adjusted off-pump under real-time echo-guidance. The adjustment tool was removed and the atriotomy was closed with a purse-string suture. Control animals (group B, n=4) were implanted with the conventional neochordae. Animals in both groups were sacrificed 3 months after the procedure. Results: In both groups, prior to repair, mitral regurgitation (MR) was severe in all animals. In group A, following adjustment of neochordae, MR was absent in all animals, with the exception of two animals that had residual 2+ MR irresponsive to neochordae adjustments. In group B, MR was 2+ in two of the four animals following repair. At 3 months, mitral competence was stable in all animals. At necropsy, normal healing of the papillary head and leaflet was observed in both the groups. Conclusions: The V-Chordal system simplifies the process of neochordal implantation and precise off-pump adjustment of the neochordal length to correct MR occurring due to a flail leaflet. This technology may improve the technical feasibility for adoption of chordal repair during open or minimally invasive surgical procedure

    Urinary Extracellular Domain of Neurotrophin Receptor p75 as a Biomarker for Amyotrophic Lateral Sclerosis in a Chinese cohort

    Get PDF
    To comprehensively assess whether p75ECD in urine could be a candidate biomarker for ALS evaluation. Urine samples were collected from 101 ALS patients, 108 patients with other neurological disease (OND) and 97 healthy controls. 61 ALS patients were followed up with clinical data including ALSFRS-r every 6 to 12 months, 23 ALS patients died and 17 ALS patients lost touch during follow up period. Enzyme-linked immunoassay was employed to determine urine p75ECD concentration. The ALSFRS-r was employed to assess the severity of ALS. The concentration of p75ECD in ALS was significantly higher than that of OND and CTRL (p < 0.001). Additionally, urine p75ECD concentrations in ALS-definite grade patients were significantly higher than that in ALS-probable grade and ALS-possible grade patients (p < 0.001). Higher urine p75ECD concentrations were correlated with increased clinical stage (p = 0.0309); urine p75ECD concentrations and ALSFRS-r were negatively correlated (p = 0.022); and urine p75ECD concentration in the fast-progressing ALS group was significantly higher than that in slow-progression (p = 0.0026). Our finding indicates that urine p75ECD concentration provides additional evidence for patients with clinically suspected ALS, and can be employed to evaluate ALS-severity

    Design, Analysis and Testing of a Novel Mitral Valve for Transcatheter Implantation

    Get PDF
    Mitral regurgitation is a common mitral valve dysfunction which may lead to heart failure. Because of the rapid aging of the population, conventional surgical repair and replacement of the pathological valve are often unsuitable for about half of symptomatic patients, who are judged high-risk. Transcatheter valve implantation could represent an effective solution. However, currently available aortic valve devices are inapt for the mitral position. This paper presents the design, development and hydrodynamic assessment of a novel bi-leaflet mitral valve suitable for transcatheter implantation. The device consists of two leaflets and a sealing component made from bovine pericardium, supported by a self-expanding wireframe made from superelastic NiTi alloy. A parametric design procedure based on numerical simulations was implemented to identify design parameters providing acceptable stress levels and maximum coaptation area for the leaflets. The wireframe was designed to host the leaflets and was optimised numerically to minimise the stresses for crimping in an 8 mm sheath for percutaneous delivery. Prototypes were built and their hydrodynamic performances were tested on a cardiac pulse duplicator, in compliance with the ISO5840-3:2013 standard. The numerical results and hydrodynamic tests show the feasibility of the device to be adopted as a transcatheter valve implant for treating mitral regurgitation

    Deletion of the BDNF Truncated Receptor TrkB.T1 Delays Disease Onset in a Mouse Model of Amyotrophic Lateral Sclerosis

    Get PDF
    Brain Derived Neurotrophic Factor (BDNF) exerts strong pro-survival effects on developing and injured motoneurons. However, in clinical trials, BDNF has failed to benefit patients with amyotrophic lateral sclerosis (ALS). To date, the cause of this failure remains unclear. Motoneurons express the TrkB kinase receptor but also high levels of the truncated TrkB.T1 receptor isoform. Thus, we investigated whether the presence of this receptor may affect the response of diseased motoneurons to endogenous BDNF. We deleted TrkB.T1 in the hSOD1G93A ALS mouse model and evaluated the impact of this mutation on motoneuron death, muscle weakness and disease progression. We found that TrkB.T1 deletion significantly slowed the onset of motor neuron degeneration. Moreover, it delayed the development of muscle weakness by 33 days. Although the life span of the animals was not affected we observed an overall improvement in the neurological score at the late stage of the disease. To investigate the effectiveness of strategies aimed at bypassing the TrkB.T1 limit to BDNF signaling we treated SOD1 mutant mice with the adenosine A2A receptor agonist CGS21680, which can activate motoneuron TrkB receptor signaling independent of neurotrophins. We found that CGS21680 treatment slowed the onset of motor neuron degeneration and muscle weakness similarly to TrkB.T1 removal. Together, our data provide evidence that endogenous TrkB.T1 limits motoneuron responsiveness to BDNF in vivo and suggest that new strategies such as Trk receptor transactivation may be used for therapeutic intervention in ALS or other neurodegenerative disorders

    Interview and interrogation methods and their effects on true and false confessions

    Get PDF
    The interviewing and interrogation of suspects can be particularly important to securing convictions against the guilty and freeing the wrongly accused. There are two general methods of questioning suspects: information-gathering and accusatorial. The information-gathering approach, used in the United Kingdom, New Zealand, Australia, and elsewhere, as more generally in Western Europe, is characterized by rapport-building, truth-seeking, and active listening. The accusatorial approach, used primarily in the United States and Canada, is characterized by accusation, confrontation, psychological manipulation, and the disallowing of denials. Which method is more effective has become a hotly debated topic as the number of false confessions identified continues to rise. Our objective was to systematically and comprehensively review published and non-published, experimental and observational studies on the effectiveness of interviewing and interrogation methods. We focus on the questioning of suspects using information-gathering and accusatorial methods seeking to elicit confessions

    Which Is Better? “Live” Surgical Broadcasts vs

    No full text
    corecore