1,153 research outputs found
The 10 Tesla muSR instrument: detector solutions
Solutions to the detector system of the High-Field muSR instrument at the
Paul Scherrer Institut (PSI) in Switzerland are presented. The strict technical
requirements are fulfilled through the application of Geiger-mode Avalanche
Photodiodes.Comment: 6 pages, 4 figure
The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for SR measurements on a continuous-wave beam
We report on the design and commissioning of a new spectrometer for muon-spin
relaxation/rotation studies installed at the Swiss Muon Source (SS) of the
Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially
a new design and replaces the old general-purpose surface-muon instrument (GPS)
which has been for long the workhorse of the SR user facility at PSI. By
making use of muon and positron detectors made of plastic scintillators read
out by silicon photomultipliers (SiPMs), a time resolution of the complete
instrument of about 160 ps (standard deviation) could be achieved. In addition,
the absence of light guides, which are needed in traditionally built SR
instrument to deliver the scintillation light to photomultiplier tubes located
outside magnetic fields applied, allowed us to design a compact instrument with
a detector set covering an increased solid angle compared to the old GPS.Comment: 11 pages, 11 figure
A time-resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode
In this work we attempt to establish the best time resolution attainable with
a scintillation counter consisting of a plastic scintillator read out by a
Geiger-mode Avalanche Photodiode. The measured time resolution is inversely
proportional to the square root of the energy deposited in the scintillator,
and scales to 18ps (sigma) at 1MeV. This result competes with the best ones
reported for photomultiplier tubes.Comment: 8 pages, 8 figure
Rotor blade construction for circulation control aircraft
A circulation control aircraft rotor blade having a spanwise Coanda surface 16 and a plurality of spanwise extending flexible composite material panels 18 cooperating with the surface to define slots for the discharge of compressed air from within the blade with each panel having first flexure means 60 associated with screw adjustments 36 for establishing a slot opening preload and second flexure means 62 associated with screw adjustments 38 for establishing a slot maximum opening
A lens-coupled scintillation counter in cryogenic environment
In this work we present an elegant solution for a scintillation counter to be
integrated into a cryogenic system. Its distinguishing feature is the absence
of a continuous light guide coupling the scintillation and the photodetector
parts, operating at cryogenic and room temperatures respectively. The prototype
detector consists of a plastic scintillator with glued-in wavelength-shifting
fiber located inside a cryostat, a Geiger-mode Avalanche Photodiode (G-APD)
outside the cryostat, and a lens system guiding the scintillation light
re-emitted by the fiber to the G-APD through optical windows in the cryostat
shields. With a 0.8mm diameter multiclad fiber and a 1mm active area G-APD the
coupling efficiency of the "lens light guide" is about 50%. A reliable
performance of the detector down to 3K is demonstrated.Comment: 14 pages, 11 figure
A new technique for elucidating -decay schemes which involve daughter nuclei with very low energy excited states
A new technique of elucidating -decay schemes of isotopes with large
density of states at low excitation energies has been developed, in which a
Broad Energy Germanium (BEGe) detector is used in conjunction with coaxial
hyper-pure germanium detectors. The power of this technique has been
demonstrated on the example of 183Hg decay. Mass-separated samples of 183Hg
were produced by a deposition of the low-energy radioactive-ion beam delivered
by the ISOLDE facility at CERN. The excellent energy resolution of the BEGe
detector allowed rays energies to be determined with a precision of a
few tens of electronvolts, which was sufficient for the analysis of the
Rydberg-Ritz combinations in the level scheme. The timestamped structure of the
data was used for unambiguous separation of rays arising from the
decay of 183Hg from those due to the daughter decays
Microstructure of (Hf-Ta-Zr-Nb)C high-entropy carbide at micro and nano/atomic level
Support from the projects APVV-15-0469, APVV-15-0621, VEGA 2/0163/16, and VEGA 2/0082/17 is acknowledged. MJR and EGC acknowledge the support of EPSRC grant XMAT (EP/K008749/2)
- …