1,153 research outputs found

    The 10 Tesla muSR instrument: detector solutions

    Get PDF
    Solutions to the detector system of the High-Field muSR instrument at the Paul Scherrer Institut (PSI) in Switzerland are presented. The strict technical requirements are fulfilled through the application of Geiger-mode Avalanche Photodiodes.Comment: 6 pages, 4 figure

    The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for μ{\mu}SR measurements on a continuous-wave beam

    Full text link
    We report on the design and commissioning of a new spectrometer for muon-spin relaxation/rotation studies installed at the Swiss Muon Source (Sμ\muS) of the Paul Scherrer Institute (PSI, Switzerland). This new instrument is essentially a new design and replaces the old general-purpose surface-muon instrument (GPS) which has been for long the workhorse of the μ\muSR user facility at PSI. By making use of muon and positron detectors made of plastic scintillators read out by silicon photomultipliers (SiPMs), a time resolution of the complete instrument of about 160 ps (standard deviation) could be achieved. In addition, the absence of light guides, which are needed in traditionally built μ\muSR instrument to deliver the scintillation light to photomultiplier tubes located outside magnetic fields applied, allowed us to design a compact instrument with a detector set covering an increased solid angle compared to the old GPS.Comment: 11 pages, 11 figure

    A time-resolution study with a plastic scintillator read out by a Geiger-mode Avalanche Photodiode

    Full text link
    In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely proportional to the square root of the energy deposited in the scintillator, and scales to 18ps (sigma) at 1MeV. This result competes with the best ones reported for photomultiplier tubes.Comment: 8 pages, 8 figure

    Rotor blade construction for circulation control aircraft

    Get PDF
    A circulation control aircraft rotor blade having a spanwise Coanda surface 16 and a plurality of spanwise extending flexible composite material panels 18 cooperating with the surface to define slots for the discharge of compressed air from within the blade with each panel having first flexure means 60 associated with screw adjustments 36 for establishing a slot opening preload and second flexure means 62 associated with screw adjustments 38 for establishing a slot maximum opening

    A lens-coupled scintillation counter in cryogenic environment

    Full text link
    In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts, operating at cryogenic and room temperatures respectively. The prototype detector consists of a plastic scintillator with glued-in wavelength-shifting fiber located inside a cryostat, a Geiger-mode Avalanche Photodiode (G-APD) outside the cryostat, and a lens system guiding the scintillation light re-emitted by the fiber to the G-APD through optical windows in the cryostat shields. With a 0.8mm diameter multiclad fiber and a 1mm active area G-APD the coupling efficiency of the "lens light guide" is about 50%. A reliable performance of the detector down to 3K is demonstrated.Comment: 14 pages, 11 figure

    A new technique for elucidating β\beta-decay schemes which involve daughter nuclei with very low energy excited states

    Get PDF
    A new technique of elucidating β\beta-decay schemes of isotopes with large density of states at low excitation energies has been developed, in which a Broad Energy Germanium (BEGe) detector is used in conjunction with coaxial hyper-pure germanium detectors. The power of this technique has been demonstrated on the example of 183Hg decay. Mass-separated samples of 183Hg were produced by a deposition of the low-energy radioactive-ion beam delivered by the ISOLDE facility at CERN. The excellent energy resolution of the BEGe detector allowed γ\gamma rays energies to be determined with a precision of a few tens of electronvolts, which was sufficient for the analysis of the Rydberg-Ritz combinations in the level scheme. The timestamped structure of the data was used for unambiguous separation of γ\gamma rays arising from the decay of 183Hg from those due to the daughter decays

    Microstructure of (Hf-Ta-Zr-Nb)C high-entropy carbide at micro and nano/atomic level

    Get PDF
    Support from the projects APVV-15-0469, APVV-15-0621, VEGA 2/0163/16, and VEGA 2/0082/17 is acknowledged. MJR and EGC acknowledge the support of EPSRC grant XMAT (EP/K008749/2)
    corecore