469 research outputs found

    Striatal BOLD Response Reflects the Impact of Herd Information on Financial Decisions

    Get PDF
    Like other species, humans are sensitive to the decisions and actions of conspecifics, which can lead to herd behavior and undesirable outcomes such as stock market bubbles and bank runs. However, how the brain processes this socially derived influence is only poorly understood. Using functional magnetic resonance imaging (fMRI), we scanned participants as they made decisions on whether to buy stocks after observing others’ buying decisions. We demonstrate that activity in the ventral striatum, an area heavily implicated in reward processing, tracked the degree of influence on participants’ decisions arising from the observation of other peoples’ decisions. The signal did not track non-human, non-social control decisions. These findings lend weight to the notion that the ventral striatum is involved in the processing of complex social aspects of decision making and identify a possible neural basis for herd behavior

    Partial Adaptation of Obtained and Observed Value Signals Preserves Information about Gains and Losses.

    Get PDF
    UNLABELLED: Given that the range of rewarding and punishing outcomes of actions is large but neural coding capacity is limited, efficient processing of outcomes by the brain is necessary. One mechanism to increase efficiency is to rescale neural output to the range of outcomes expected in the current context, and process only experienced deviations from this expectation. However, this mechanism comes at the cost of not being able to discriminate between unexpectedly low losses when times are bad versus unexpectedly high gains when times are good. Thus, too much adaptation would result in disregarding information about the nature and absolute magnitude of outcomes, preventing learning about the longer-term value structure of the environment. Here we investigate the degree of adaptation in outcome coding brain regions in humans, for directly experienced outcomes and observed outcomes. We scanned participants while they performed a social learning task in gain and loss blocks. Multivariate pattern analysis showed two distinct networks of brain regions adapt to the most likely outcomes within a block. Frontostriatal areas adapted to directly experienced outcomes, whereas lateral frontal and temporoparietal regions adapted to observed social outcomes. Critically, in both cases, adaptation was incomplete and information about whether the outcomes arose in a gain block or a loss block was retained. Univariate analysis confirmed incomplete adaptive coding in these regions but also detected nonadapting outcome signals. Thus, although neural areas rescale their responses to outcomes for efficient coding, they adapt incompletely and keep track of the longer-term incentives available in the environment. SIGNIFICANCE STATEMENT: Optimal value-based choice requires that the brain precisely and efficiently represents positive and negative outcomes. One way to increase efficiency is to adapt responding to the most likely outcomes in a given context. However, too strong adaptation would result in loss of precise representation (e.g., when the avoidance of a loss in a loss-context is coded the same as receipt of a gain in a gain-context). We investigated an intermediate form of adaptation that is efficient while maintaining information about received gains and avoided losses. We found that frontostriatal areas adapted to directly experienced outcomes, whereas lateral frontal and temporoparietal regions adapted to observed social outcomes. Importantly, adaptation was intermediate, in line with influential models of reference dependence in behavioral economics.This work was supported by the Wellcome Trust, Leverhulme Trust and the Swiss National Science Foundation (PP00P1-128574 and CRSTT3-141965).This is the final version of the article. It first appeared from the Society for Neuroscience via https://doi.org/10.1523/JNEUROSCI.0487-16.201

    Automated versus non-automated weaning for reducing the duration of mechanical ventilation for critically ill adults and children: a cochrane systematic review and meta-analysis

    Get PDF
    Automated weaning systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events. Electronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling. We identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I(2) = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high. Automated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is neede

    Optical parametric oscillation with distributed feedback in cold atoms

    Full text link
    There is currently a strong interest in mirrorless lasing systems, in which the electromagnetic feedback is provided either by disorder (multiple scattering in the gain medium) or by order (multiple Bragg reflection). These mechanisms correspond, respectively, to random lasers and photonic crystal lasers. The crossover regime between order and disorder, or correlated disorder, has also been investigated with some success. Here, we report one-dimensional photonic-crystal lasing (that is, distributed feedback lasing) with a cold atom cloud that simultaneously provides both gain and feedback. The atoms are trapped in a one-dimensional lattice, producing a density modulation that creates a strong Bragg reflection with a small angle of incidence. Pumping the atoms with auxiliary beams induces four-wave mixing, which provides parametric gain. The combination of both ingredients generates a mirrorless parametric oscillation with a conical output emission, the apex angle of which is tunable with the lattice periodicity

    RAPID : research on automated plankton identification

    Get PDF
    Author Posting. © Oceanography Society, 2007. This article is posted here by permission of Oceanography Society for personal use, not for redistribution. The definitive version was published in Oceanography 20, 2 (2007): 172-187.When Victor Hensen deployed the first true plankton1 net in 1887, he and his colleagues were attempting to answer three fundamental questions: What planktonic organisms are present in the ocean? How many of each type are present? How does the plankton’s composition change over time? Although answering these questions has remained a central goal of oceanographers, the sophisticated tools available to enumerate planktonic organisms today offer capabilities that Hensen probably could never have imagined.This material is based upon work supported by the National Science Foundation under Grants OCE-0325018, OCE-0324937, OCE-0325167 and OCE-9423471, and the European Union under grants Q5CR-2002-71699, MAS3-ct98-0188, and MAS2-ct92-0015

    Hybrid Titanium/Biodegradable Polymer Implants with an Hierarchical Pore Structure as a Means to Control Selective Cell Movement

    Get PDF
    UNLABELLED: In order to improve implant success rate, it is important to enhance their responsiveness to the prevailing conditions following implantation. Uncontrolled movement of inflammatory cells and fibroblasts is one of these in vivo problems and the porosity properties of the implant have a strong effect on these. Here, we describe a hybrid system composed of a macroporous titanium structure filled with a microporous biodegradable polymer. This polymer matrix has a distinct porosity gradient to accommodate different cell types (fibroblasts and epithelial cells). The main clinical application of this system will be the prevention of restenosis due to excessive fibroblast migration and proliferation in the case of tracheal implants. METHODOLOGY/PRINCIPAL FINDINGS: A microbead-based titanium template was filled with a porous Poly (L-lactic acid) (PLLA) body by freeze-extraction method. A distinct porosity difference was obtained between the inner and outer surfaces of the implant as characterized by image analysis and Mercury porosimetry (9.8±2.2 µm vs. 36.7±11.4 µm, p≤0.05). On top, a thin PLLA film was added to optimize the growth of epithelial cells, which was confirmed by using human respiratory epithelial cells. To check the control of fibroblast movement, PKH26 labeled fibroblasts were seeded onto Titanium and Titanium/PLLA implants. The cell movement was quantified by confocal microscopy: in one week cells moved deeper in Ti samples compared to Ti/PLLA. CONCLUSIONS: In vitro experiments showed that this new implant is effective for guiding different kind of cells it will contact upon implantation. Overall, this system would enable spatial and temporal control over cell migration by a gradient ranging from macroporosity to nanoporosity within a tracheal implant. Moreover, mechanical properties will be dependent mainly on the titanium frame. This will make it possible to create a polymeric environment which is suitable for cells without the need to meet mechanical requirements with the polymeric structure

    Risk Factors for Pharyngocutaneous Fistula After Total Pharyngolaryngectomy

    Get PDF
    Purpose:To evaluate the risk factors of pharyngocutaneous fistula after total pharyngolaryngectomy (TPL) in orderto reduce theirincidence and propose a perioperative rehabilitation protocol.Materials and Methods:This was a multicenter retrospectivestudy based on 456 patients operated for squamous cell carcinoma by total laryngectomy or TPL. Sociodemographic, medical,surgical, carcinologic, and biological risk factors were studied. Reactive C protein was evaluated on post-op day 5. Patients weredivided into a learning population and a validation population with patients who underwent surgery between 2006 and 2013 andbetween 2014 and 2016, respectively. A risk score of occurrence of salivary fistula was developed from the learning population dataand then applied on the validation population (temporal validation).Objective:To use a preoperative risk score in order tomodify practices and reduce the incidence of pharyngocutaneous fistula.Results:Four hundred fifty-six patients were included,328 in the learning population and 128 in the validation population. The combination of active smoking over 20 pack-years, ahistory of cervical radiotherapy, mucosal closure in separate stitches instead of running sutures, and the placement of a pedicleflap instead of a free flap led to a maximum risk of post-op pharyngocutaneous fistula after TPL. The risk score was discriminantwith an area under the receiver operating characteristic curve of 0.66 (95% confidence interval [CI]¼0.59-0.73) and 0.70 (95% CI¼0.60-0.81) for the learning population and the validation population, respectively.Conclusion:A preoperative risk score couldbe used to reduce the rate of pharyngocutaneous fistula after TPL by removing 1 or more of the 4 identified risk factors

    Doses to internal organs for various breast radiation techniques - implications on the risk of secondary cancers and cardiomyopathy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Breast cancers are more frequently diagnosed at an early stage and currently have improved long term outcomes. Late normal tissue complications induced by adjuvant radiotherapy like secondary cancers or cardiomyopathy must now be avoided at all cost. Several new breast radiotherapy techniques have been developed and this work aims at comparing the scatter doses of internal organs for those techniques.</p> <p>Methods</p> <p>A CT-scan of a typical early stage left breast cancer patient was used to describe a realistic anthropomorphic phantom in the MCNP Monte Carlo code. Dose tally detectors were placed in breasts, the heart, the ipsilateral lung, and the spleen. Five irradiation techniques were simulated: whole breast radiotherapy 50 Gy in 25 fractions using physical wedge or breast IMRT, 3D-CRT partial breast radiotherapy 38.5 Gy in 10 fractions, HDR brachytherapy delivering 34 Gy in 10 treatments, or Permanent Breast <sup>103</sup>Pd Seed Implant delivering 90 Gy.</p> <p>Results</p> <p>For external beam radiotherapy the wedge compensation technique yielded the largest doses to internal organs like the spleen or the heart, respectively 2,300 mSv and 2.7 Gy. Smaller scatter dose are induced using breast IMRT, respectively 810 mSv and 1.1 Gy, or 3D-CRT partial breast irradiation, respectively 130 mSv and 0.7 Gy. Dose to the lung is also smaller for IMRT and 3D-CRT compared to the wedge technique. For multicatheter HDR brachytherapy a large dose is delivered to the heart, 3.6 Gy, the spleen receives 1,171 mSv and the lung receives 2,471 mSv. These values are 44% higher in case of a balloon catheter. In contrast, breast seeds implant is associated with low dose to most internal organs.</p> <p>Conclusions</p> <p>The present data support the use of breast IMRT or virtual wedge technique instead of physical wedges for whole breast radiotherapy. Regarding partial breast irradiation techniques, low energy source brachytherapy and external beam 3D-CRT appear safer than <sup>192</sup>Ir HDR techniques.</p
    • …
    corecore