6 research outputs found
Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991–0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757–0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD. Trial registration: ClinicalTrials.gov NCT03349801. Registered on 22 November 2017
Characteristics and Spatial Distribution of Structural Features in Age-Related Macular Degeneration: A MACUSTAR Study Report
Purpose: To report the prevalence and topographic distribution of structural characteristics in study participants with age-related macular degeneration (AMD) and controls in the cross-sectional study part of the MACUSTAR study (ClinicalTrials.gov Identifier: NCT03349801). Design: European, multicenter cohort study. Subjects: Overall, 301 eyes of 301 subjects with early (n = 34), intermediate (n = 168), and late AMD (n = 43), as well as eyes without any AMD features (n = 56). Methods: In study eyes with intermediate AMD (iAMD), the presence of structural AMD biomarkers, including pigmentary abnormalities (PAs), pigment epithelium detachment (PED), refractile deposits, reticular pseudodrusen (RPD), hyperreflective foci (HRF), incomplete/complete retinal pigment epithelium (RPE), and outer retinal atrophy (i/cRORA), and quiescent choroidal neovascularization (qCNV) was systematically determined in the prospectively acquired multimodal retinal imaging cross-sectional data set of MACUSTAR. Retinal layer thicknesses and the RPE drusen complex (RPEDC) volume were determined for the total study cohort in spectral-domain (SD) OCT imaging using a deep-learning–based algorithm. Main Outcome Measures: Prevalence and topographic distribution of structural iAMD features. Results: A total of 301 study eyes of 301 subjects with a mean (± standard deviation) age of 71.2 ± 7.20 years (63.1% women) were included. Besides large drusen, the most prevalent structural feature in iAMD study eyes were PA (57.1%), followed by HRF (51.8%) and RPD (22.0%). Pigment epithelium detachment lesions were observed in 4.8%, vitelliform lesions in 4.2%, refractile deposits in 3.0%, and qCNV in 2.4%. Direct precursor lesions for manifest retinal atrophy were detected in 10.7% (iRORA) and 4.2% (cRORA) in iAMD eyes. Overall, the highest RPEDC volume with a median of 98.92 × 10−4 mm³ was found in iAMD study eyes. Spatial analysis demonstrated a predominant distribution of RPD in the superior and temporal subfields at a foveal eccentricity of 1.5 to 2 mm, whereas HRF and large drusen had a distinct topographic distribution involving the foveal center. Conclusions: Detailed knowledge of the prevalence and distribution of structural iAMD biomarkers is vital to identify reliable outcome measure for disease progression. Longitudinal analyses are needed to evaluate their prognostic value for conversion to advanced disease stages. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references
Author Correction: Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report (vol 12, 21911, 2022)
Ophthalmic researc
Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991–0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757–0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD
Recommended from our members
Development and Valuation of a Preference-Weighted Measure in Age-Related Macular Degeneration From the Vision Impairment in Low Luminance Questionnaire—A MACUSTAR Report
Objectives: This study generates VILL-UI (Vision Impairment in Low Luminance - Utility Index), a preference-weighted measure (PWM) derived from the VILL-33 measure for use in patients with age-related macular degeneration (AMD) and valued to generate United Kingdom and German preference weights.
Methods: A PWM consists of a classification system to describe health and utility values for every state described by the classification. The classification was derived using existing data collected as part of the MACUSTAR study, a low-interventional study on AMD, conducted at 20 clinical sites across Europe. Items were selected using psychometric and Rasch analyses, published criteria around PWM suitability, alongside instrument developer views and concept elicitation work that informed VILL-33 development. An online discrete choice experiment (DCE) with duration of the health state was conducted with the United Kingdom and German public. Responses were modeled to generate utility values for all possible health states.
Results: The classification system has 5 items across the 3 domains of VILL-33: reading and accessing information, mobility and safety, and emotional well-being. The DCE samples (United Kingdom: n = 1004, Germany: n = 1008) are broadly representative and demonstrate good understanding of the tasks. The final DCE analyses produce logically consistent and significant coefficients.
Conclusions: This study enables responses to VILL-33 to be directly used to inform economic evaluation in AMD. The elicitation of preferences from both United Kingdom and Germany enables greater application of VILL-UI for economic evaluation throughout Europe. VILL-UI fills a gap in AMD in which generic preference-weighted measures typically lack sensitivity
Challenges, facilitators and barriers to screening study participants in early disease stages-experience from the MACUSTAR study
Background!#!Recruiting asymptomatic participants with early disease stages into studies is challenging and only little is known about facilitators and barriers to screening and recruitment of study participants. Thus we assessed factors associated with screening rates in the MACUSTAR study, a multi-centre, low-interventional cohort study of early stages of age-related macular degeneration (AMD).!##!Methods!#!Screening rates per clinical site and per week were compiled and applicable recruitment factors were assigned to respective time periods. A generalized linear mixed-effects model including the most relevant recruitment factors identified via in-depth interviews with study personnel was fitted to the screening data. Only participants with intermediate AMD were considered.!##!Results!#!A total of 766 individual screenings within 87 weeks were available for analysis. The mean screening rate was 0.6 ± 0.9 screenings per week among all sites. The participation at investigator teleconferences (relative risk increase 1.466, 95% CI [1.018-2.112]), public holidays (relative risk decrease 0.466, 95% CI [0.367-0.591]) and reaching 80% of the site's recruitment target (relative risk decrease 0.699, 95% CI [0.367-0.591]) were associated with the number of screenings at an individual site level.!##!Conclusions!#!Careful planning of screening activities is necessary when recruiting early disease stages in multi-centre observational or low-interventional studies. Conducting teleconferences with local investigators can increase screening rates. When planning recruitment, seasonal and saturation effects at clinical site level need to be taken into account.!##!Trial registration!#!ClinicalTrials.gov NCT03349801 . Registered on 22 November 2017