548 research outputs found

    Female home range size is regulated by resource distribution and intraspecific competition: a long-term field study

    Full text link
    The size of an individual’s home range is an important feature, influencing reproduction and survival, but it can vary considerably among both populations and individuals. The factors accounting for such variation are still poorly understood, and comprehensive long-term field studies considering various environmental factors that influence home range size are rare. We investigated the effects of seasonality, availability of food, cover, number of direct neighbours and the relative individual body mass on home range sizes in 125 adult female striped mice, Rhabdomys pumilio, in South Africa from 2004 to 2008. We used radiotelemetry to estimate home range sizes, trapping to determine the number of direct neighbours, and plant surveys in every home range to determine availability of food and cover. Home ranges were smaller when food quantity was high, many territorial neighbours were present, females had a relatively small body mass and during the nonbreeding season. We conclude that the availability of food resources and intraspecific competition are the main factors influencing home range size in female striped mice. Females enlarged their home ranges when territorial neighbours were few, and there was a significant positive correlation between home range size and quantity of food plants. This indicates that home range size might not reflect the minimal trade-off between access to resources that allow for a female’s survival and lowest cost for defending and foraging in that area. Instead, we propose a hypothesis for future research that female striped mice occupy areas several times larger than needed to improve their fitness by providing resources for future offspring

    Computer-assisted detection of pulmonary embolism: evaluation of pulmonary CT angiograms performed in an on-call setting

    Get PDF
    Item does not contain fulltextPURPOSE: The purpose of the study was to assess the stand-alone performance of computer-assisted detection (CAD) for evaluation of pulmonary CT angiograms (CTPA) performed in an on-call setting. METHODS: In this institutional review board-approved study, we retrospectively included 292 consecutive CTPA performed during night shifts and weekends over a period of 16 months. Original reports were compared with a dedicated CAD system for pulmonary emboli (PE). A reference standard for the presence of PE was established using independent evaluation by two readers and consultation of a third experienced radiologist in discordant cases. RESULTS: Original reports had described 225 negative studies and 67 positive studies for PE. CAD found PE in seven patients originally reported as negative but identified by independent evaluation: emboli were located in segmental (n = 2) and subsegmental arteries (n = 5). The negative predictive value (NPV) of the CAD algorithm was 92% (44/48). On average there were 4.7 false positives (FP) per examination (median 2, range 0-42). In 72% of studies or=10 FP. CONCLUSION: CAD identified small emboli originally missed under clinical conditions and found 93% of the isolated subsegmental emboli. On average there were 4.7 FP per examination.1 april 201

    Evolution of humoral immune response to SARS-CoV-2 mRNA vaccine in liver transplant recipients - a longitudinal study.

    Get PDF
    BACKGROUND AND AIM Liver transplant recipients show suboptimal vaccine-elicited immune responses to severe acute respiratory coronavirus 2 (SARS-CoV-2) vaccination. This study aimed to assess real-world data on SARS-CoV-2 antibodies after the second and third SARS-CoV-2 vaccination in liver transplant recipients in Switzerland. METHODS We enrolled liver transplant recipients who attended regular follow-up visits between 01/07/2021 and 30/04/2022 at the outpatient clinic of the Department of Visceral Surgery and Medicine at Bern University Hospital, Switzerland. Following the Swiss Federal Office of Public Health recommendations, we measured SARS-CoV-2 anti-spike IgG antibodies in 117 liver transplant recipients ≄4 weeks after the second SARS-CoV-2 mRNA vaccination from 07/2021-04/2022. In case of antibody levels of 100 AU/ml were defined as "responders", those with 12-100 AU/ml as "partial responders" and those with <12 AU/ml as "non-responders". RESULTS After two vaccinations, 36/117 (31%) were responders, 42/117 (36%) were partial responders and 39/117 (33%) were non-responders. The humoral immune response improved significantly after the third vaccination, resulting in 31/55 (56%) responders among the previous partial or non-responders. A total of 26 patients developed COVID-19, of whom two had a moderate or severe course (both non-responders after three doses). DISCUSSION One third of liver transplant recipients showed an optimal response following two vaccinations; a third dose achieved a complete antibody response in more than half of partial and non-responders. We observed only one severe course of COVID-19 and no deaths from COVID-19 in the vaccinated liver transplant recipients

    Value of minimum intensity projections for chest CT in COVID-19 patients

    Get PDF
    Purpose: To investigate whether minimum intensity projection (MinIP) reconstructions enable more accurate depiction of pulmonary ground-glass opacity (GGO) compared to standard transverse sections and multiplanar reformat (MPR) series in patients with suspected coronavirus disease 2019 (COVID-19). Method: In this multinational study, chest CT scans of 185 patients were retrospectively analyzed. Diagnostic accuracy, diagnostic confidence, image quality regarding the assessment of GGO, as well as subjective time-efficiency of MinIP and standard MPR series were analyzed based on the assessment of six radiologists. In addition, the suitability for COVID-19 evaluation, image quality regarding GGO and subjective time-efficiency in clinical routine was assessed by five clinicians. Results: The reference standard revealed a total of 149 CT scans with pulmonary GGO. MinIP reconstructions yielded significantly higher sensitivity (99.9 % vs 95.6 %), specificity (95.8 % vs 86.1 %) and accuracy (99.1 % vs 93.8 %) for assessing of GGO compared with standard MPR series. MinIP reconstructions achieved significantly higher ratings by radiologists concerning diagnostic confidence (medians, 5.00 vs 4.00), image quality (medians, 4.00 vs 4.00), contrast between GGO and unaffected lung parenchyma (medians, 5.00 vs 4.00) as well as subjective time-efficiency (medians, 5.00 vs 4.00) compared with MPR-series (all P &lt;.001). Clinicians preferred MinIP reconstructions for COVID-19 assessment (medians, 5.00 vs 3.00), image quality regarding GGO (medians, 5.00 vs 3.00) and subjective time-efficiency in clinical routine (medians, 5.00 vs 3.00). Conclusions: MinIP reconstructions improve the assessment of COVID-19 in chest CT compared to standard images and may be suitable for routine application

    Diagnosis of obstructive coronary artery disease using computed tomography angiography in patients with stable chest pain depending on clinical probability and in clinically important subgroups: meta-analysis of individual patient data

    Get PDF
    OBJECTIVE: To determine whether coronary computed tomography angiography (CTA) should be performed in patients with any clinical probability of coronary artery disease (CAD), and whether the diagnostic performance differs between subgroups of patients. DESIGN: Prospectively designed meta-analysis of individual patient data from prospective diagnostic accuracy studies. DATA SOURCES: Medline, Embase, and Web of Science for published studies. Unpublished studies were identified via direct contact with participating investigators. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Prospective diagnostic accuracy studies that compared coronary CTA with coronary angiography as the reference standard, using at least a 50% diameter reduction as a cutoff value for obstructive CAD. All patients needed to have a clinical indication for coronary angiography due to suspected CAD, and both tests had to be performed in all patients. Results had to be provided using 2×2 or 3×2 cross tabulations for the comparison of CTA with coronary angiography. Primary outcomes were the positive and negative predictive values of CTA as a function of clinical pretest probability of obstructive CAD, analysed by a generalised linear mixed model; calculations were performed including and excluding non-diagnostic CTA results. The no-treat/treat threshold model was used to determine the range of appropriate pretest probabilities for CTA. The threshold model was based on obtained post-test probabilities of less than 15% in case of negative CTA and above 50% in case of positive CTA. Sex, angina pectoris type, age, and number of computed tomography detector rows were used as clinical variables to analyse the diagnostic performance in relevant subgroups. RESULTS: Individual patient data from 5332 patients from 65 prospective diagnostic accuracy studies were retrieved. For a pretest probability range of 7-67%, the treat threshold of more than 50% and the no-treat threshold of less than 15% post-test probability were obtained using CTA. At a pretest probability of 7%, the positive predictive value of CTA was 50.9% (95% confidence interval 43.3% to 57.7%) and the negative predictive value of CTA was 97.8% (96.4% to 98.7%); corresponding values at a pretest probability of 67% were 82.7% (78.3% to 86.2%) and 85.0% (80.2% to 88.9%), respectively. The overall sensitivity of CTA was 95.2% (92.6% to 96.9%) and the specificity was 79.2% (74.9% to 82.9%). CTA using more than 64 detector rows was associated with a higher empirical sensitivity than CTA using up to 64 rows (93.4% v 86.5%, P=0.002) and specificity (84.4% v 72.6%, P<0.001). The area under the receiver-operating-characteristic curve for CTA was 0.897 (0.889 to 0.906), and the diagnostic performance of CTA was slightly lower in women than in with men (area under the curve 0.874 (0.858 to 0.890) v 0.907 (0.897 to 0.916), P<0.001). The diagnostic performance of CTA was slightly lower in patients older than 75 (0.864 (0.834 to 0.894), P=0.018 v all other age groups) and was not significantly influenced by angina pectoris type (typical angina 0.895 (0.873 to 0.917), atypical angina 0.898 (0.884 to 0.913), non-anginal chest pain 0.884 (0.870 to 0.899), other chest discomfort 0.915 (0.897 to 0.934)). CONCLUSIONS: In a no-treat/treat threshold model, the diagnosis of obstructive CAD using coronary CTA in patients with stable chest pain was most accurate when the clinical pretest probability was between 7% and 67%. Performance of CTA was not influenced by the angina pectoris type and was slightly higher in men and lower in older patients. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42012002780
    • 

    corecore