47 research outputs found

    Nonlocal ultrafast demagnetization dynamics of Co/Pt multilayers by optical field enhancement

    Get PDF
    The influence on ultrafast demagnetization dynamics of metallic nano-structured gratings deposited on thin films of magnetic Co/Pt multilayers is investigated by the time-resolved optical Kerr effect. Depending on the polarization of the pump pulse, a pronounced enhancement of the demagnetization amplitude is found. Calculation of the inhomogeneous optical field distribution due to plasmon interaction and time-dependent solutions of the coupled electron, lattice, and spin temperatures in two dimensions show good agreement with the experimental data, as well as giving evidence of non-local demagnetization dynamics due to electron diffusion.BMBF, 05K10KTB, Verbundprojekt: FSP 301 - FLASH: Nanoskopische Systeme. Teilprojekt 1.1: Universelle Experimentierkammer für Streuexperimente mit kohärenten Femtosekunden-Röntgenpulsen Multi Purpose Coherent Scattering Chamber for FLASH and XFEL 'MPscatt

    Femtosecond holography in lithium niobate crystals

    Get PDF
    Spatial gratings are recorded holographically by two femtosecond pump pulses at 388 nm in lithium niobate (LiNbO3) crystals and read out by a Bragg-matched, temporally delayed probe pulse at 776 nm. We claim, to our knowledge, the first holographic pump-probe experiments with subpicosecond temporal resolution for LiNbO3. An instantaneous grating that is due mostly to the Kerr effect as well as a long-lasting grating that results mainly from the absorption caused by photoexcited carriers was observed. The Kerr coefficient of LiNbO3 for our experimental conditions, i.e., pumped and probed at different wavelengths, was approximately 1.0×10^-5 cm²/GW

    Picosecond x-ray magnetic circular dichroism spectroscopy at the Fe L-edges with a laser-driven plasma source

    Full text link
    Time-resolved x-ray magnetic circular dichroism (XMCD) enables a unique spectroscopic view on complex spin and charge dynamics in multi-elemental magnetic materials. So far, its application in the soft-x-ray range has been limited to synchrotron-radiation sources and free-electron lasers. By combining a laser-driven plasma source with a magnetic thin-film polarizer, we generate circularly polarized photons in the soft x-ray regime, enabling the first XMCD spectroscopy at the Fe L edges in a laser laboratory. Our approach can be readily adapted to other transition metal L and rare earth M absorption edges and with a temporal resolution of < 10 ps, a wide range of ultrafast magnetization studies can be realized.Comment: 7 pages, 4 figures, supplemental materia

    Experimental evaluation of signal-to-noise in spectro-holography via modified uniformly redundant arrays in the soft x-ray and extreme ultraviolet spectral regime

    Get PDF
    We present dichroic x-ray lensless magnetic imaging by Fourier transform holography with an extended reference scheme via a modified uniformly redundant array (mURA). Holographic images of magnetic domains simultaneously generated by a single pinhole reference as well as by a mURA reference are compared with respect to the signal-to-noise ratio (SNR) as a function of exposure time. We apply this approach for spectro-holographic imaging of ferromagnetic domain patterns in Co/Pt multilayer films. Soft x-rays with wavelengths of 1.59 nm (Co L 3 absorption edge) and 20.8 nm (Co M 2,3 absorption edges) are used for image formation and to generate contrast via x-ray magnetic circular dichroism. For a given exposure time, the mURA-based holography allows to decouple the reconstruction SNR from the spatial resolution. For 1.59 nm wavelength, the reconstruction via the extended reference scheme shows no significant loss of spatial resolution compared to the single pinhole reference. In contrast, at 20.8 nm wavelength the single pinhole reveals some very intricate features which are lost in the image generated by the mURA, although overall a high-quality image is generated. The SNR-advantage of the mURA scheme is most notable when the hologram has to be encoded with few photons, while errors associated with the increased complexity of the reconstruction process reduce the advantage for high-photon-number experiments.BMBF, 05K13KT3, Verbundprojekt 05K2013 - DynaMaX: Messplatz für ultraschnelle Dynamik bei BESSY II. Teilprojekt

    Accelerating double pulse all-optical write/erase cycles in metallic ferrimagnets

    Get PDF
    All-optical switching of magnetic order presents a promising route toward faster and more energy efficient data storage. However, a realization in future devices is ultimately dependent on the maximum repetition rates of optically induced write/erase cycles. Here, we present two strategies to minimize the temporal separation of two consecutive femtosecond laser pulses to toggle the out-of-plane direction of the magnetization of ferrimagnetic rare-earth transition metal alloys. First, by systematically changing the heat transfer rates using either amorphous glass, crystalline silicon, or polycrystalline diamond substrates, we show that efficient cooling rates of the magnetic system present a prerequisite to accelerate the sequence of double pulse toggle switching. Second, we demonstrate that replacing the transition metal iron by cobalt leads to a significantly faster recovery of the magnetization after optical excitation allowing us to approach terahertz frequency of write/erase cycles with a minimum pulse-to-pulse separation of 7 ps

    Optical inter-site spin transfer probed by energy and spin-resolved transient absorption spectroscopy

    Get PDF
    Optically driven spin transport is the fastest and most efficient process to manipulate macroscopic magnetization as it does not rely on secondary mechanisms to dissipate angular momentum. In the present work, we show that such an optical inter-site spin transfer (OISTR) from Pt to Co emerges as a dominant mechanism governing the ultrafast magnetization dynamics of a CoPt alloy. To demonstrate this, we perform a joint theoretical and experimental investigation to determine the transient changes of the helicity dependent absorption in the extreme ultraviolet spectral range. We show that the helicity dependent absorption is directly related to changes of the transient spin-split density of states, allowing us to link the origin of OISTR to the available minority states above the Fermi level. This makes OISTR a general phenomenon in optical manipulation of multi-component magnetic systems. Optically driven spin transfer is the fastest process to manipulate magnetism. Here, the authors show that this process emerges as the dominant mechanism in femtosecond spin dynamics enabling to the engineering of functional magnetic systems for future all optical technologies

    High-resolution magnetic-domain imaging by Fourier transform holography at 21 nm wavelength

    Get PDF
    Exploiting x-ray magnetic circular dichroism at the L-edges of 3d transition metals, Fourier transform holography has become a standard technique to investigate magnetic samples with sub-100 nm spatial resolution. Here, magnetic imaging in the 21 nm wavelength regime using M-edge circular dichroism is demonstrated. Ultrafast pulses in this wavelength regime are increasingly available from both laser- and accelerator-driven soft x-ray sources. We explain the adaptations concerning sample preparation and data evaluation compared to conventional holography in the 1 nm wavelength range. We find the correction of the Fourier transform hologram to in-plane Fourier components to be critical for high-quality reconstruction and demonstrate 70 nm spatial resolution in magnetization imaging with this approach.BMBF, 05K10KTB, Verbundprojekt: FSP 301 - FLASH: Nanoskopische Systeme. Teilprojekt 1.1: Universelle Experimentierkammer für Streuexperimente mit kohärenten Femtosekunden-Röntgenpulsen Multi Purpose Coherent Scattering Chamber for FLASH and XFEL 'MPscatt'
    corecore