945 research outputs found

    Applications of Kalman Filters for Coherent Optical Communication Systems

    Get PDF
    In this chapter, we review various applications of Kalman filtering for coherent optical communication systems. First, we briefly discuss the principles of Kalman filter and its variations including extended Kalman filter (EKF) and adaptive Kalman filter (AKF). Later on, we illustrate the applicability of Kalman filters for joint tracking of several optical transmission impairments, simultaneously, by formulating the state space model (SSM) and detailing the principles. A detailed methodology is presented for the joint tracking of linear and nonlinear phase noise along with amplitude noise using EKF. Also, approaches to enhance the performance obtained by EKF by combining with other existing digital signal processing (DSP) techniques are presented. Frequency and phase offset estimation using a two stage linear Kalman filter (LKF)/EKF is also discussed. A cascaded structure of LKF and EKF by splitting the SSM to jointly mitigate the effects of polarization, phase and amplitude noise is also presented. The numerical analysis concludes that the Kalman filter based approaches outperform the conventional methods with better tracking capability and faster convergence besides offering more feasibility for real-time implementations

    Dilated Convolutional Neural Networks for Cardiovascular MR Segmentation in Congenital Heart Disease

    Full text link
    We propose an automatic method using dilated convolutional neural networks (CNNs) for segmentation of the myocardium and blood pool in cardiovascular MR (CMR) of patients with congenital heart disease (CHD). Ten training and ten test CMR scans cropped to an ROI around the heart were provided in the MICCAI 2016 HVSMR challenge. A dilated CNN with a receptive field of 131x131 voxels was trained for myocardium and blood pool segmentation in axial, sagittal and coronal image slices. Performance was evaluated within the HVSMR challenge. Automatic segmentation of the test scans resulted in Dice indices of 0.80±\pm0.06 and 0.93±\pm0.02, average distances to boundaries of 0.96±\pm0.31 and 0.89±\pm0.24 mm, and Hausdorff distances of 6.13±\pm3.76 and 7.07±\pm3.01 mm for the myocardium and blood pool, respectively. Segmentation took 41.5±\pm14.7 s per scan. In conclusion, dilated CNNs trained on a small set of CMR images of CHD patients showing large anatomical variability provide accurate myocardium and blood pool segmentations

    Silicon Photonics Wavelength-Independent C-Band Tunable Optical Filter With Feasible Thermal Tuning Requirements

    Full text link
    A filter design based on Vernier microrings and wideband directional couplers is proposed for ASE noise suppression in next generation DCI applications. We demonstrate a 40 nm FSR-free filter with > 20.5 dB average ER and 3dB-BW of 75 GHz, achieving wavelength-independent performance and full tunability with a maximum tuning temperature of 75 K.Comment: This work has been partially funded by the German Ministry of Education and Research under the grant agreement 13N14937 (PEARLS

    Implant-Based Breast Reconstruction after Mastectomy, from the Subpectoral to the Prepectoral Approach: An Evidence-Based Change of Mind?

    Get PDF
    Over the last years, prepectoral implant-based breast reconstruction has undergone a renaissance due to several technical advancements regarding mastectomy techniques and surgical approaches for the placement and soft tissue coverage of silicone implants. Initially abandoned due to the high incidence of complications, such as capsular contraction, implant extrusion, and poor aesthetic outcome, the effective prevention of these types of complications led to the prepectoral technique coming back in style for the ease of implant placement and the conservation of the pectoralis muscle function. Additional advantages such as a decrease of postoperative pain, animation deformity, and operative time contribute to the steady gain in popularity. This review aims to summarize the factors influencing the trend towards prepectoral implant-based breast reconstruction and to discuss the challenges and prospects related to this operative approach

    Modelling of aortic aneurysm and aortic dissection through 3D printing

    Get PDF
    Introduction: The aim of this study was to assess if the complex anatomy of aortic aneurysm and aortic dissection can be accurately reproduced from a contrast-enhanced computed tomography (CT) scan into a three-dimensional (3D) printed model. Methods: Contrast-enhanced cardiac CT scans from two patients were post-processed and produced as 3D printed thoracic aorta models of aortic aneurysm and aortic dissection. The transverse diameter was measured at five anatomical landmarks for both models, compared across three stages: the original contrast-enhanced CT images, the stereolithography (STL) format computerised model prepared for 3D printing and the contrast-enhanced CT of the 3D printed model. For the model with aortic dissection, measurements of the true and false lumen were taken and compared at two points on the descending aorta. Results: Three-dimensional printed models were generated with strong and flexible plastic material with successful replication of anatomical details of aortic structures and pathologies. The mean difference in transverse vessel diameter between the contrast-enhanced CT images before and after 3D printing was 1.0 and 1.2 mm, for the first and second models respectively (standard deviation: 1.0 mm and 0.9 mm). Additionally, for the second model, the mean luminal diameter difference between the 3D printed model and CT images was 0.5 mm. Conclusion: Encouraging results were achieved with regards to reproducing 3D models depicting aortic aneurysm and aortic dissection. Variances in vessel diameter measurement outside a standard deviation of 1 mm tolerance indicate further work is required into the assessment and accuracy of 3D model reproduction. © 2017 Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology

    Assessing the impact: A descriptive phenomenological study examining the provision of sustainability initiatives in higher education and the impact on stakeholder values, perceptions, and behavior

    Get PDF
    Understanding what, and how, knowledge is communicated is critical in assessing how well information is transmitted in higher education. This is especially true when dealing with new fields of study or integrated practices that attempt to reach across the campus, to multiple stakeholders. This research project was conducted in order to examine differing approaches to sustainability and the real impact sustainability-oriented courses and campus operations and activities have on students and other stakeholders. Focusing on two higher education institutions in North Carolina, a descriptive phenomenological study utilizing mixed methods, was undertaken in order to further understand the values, perceptions, and behavioral connections and meanings made by students, faculty, and administration when presented with education for sustainability or related campus activities. This project was created with the intention of taking a more holistic approach in the exploration of how institutions go about imparting knowledge related to sustainability and even more critically, how it is received and applied

    Multipurpose Polymer Bragg Grating-Based Optomechanical Sensor Pad

    Get PDF
    Flexible epoxy waveguide Bragg gratings are fabricated on a low-modulus TPX™ polymethylpentene polyolefin substrate for an easy to manufacture and low-cost optomechanical sensor pad providing exceedingly multipurpose application potentials. Rectangular EpoCore negative resist strip waveguides are formed employing standard UV mask lithography. Highly persistent Bragg gratings are inscribed directly into the channel waveguides by permanently modifying the local refractive indices through a well-defined KrF excimer laser irradiated +1/-1 order phase mask. The reproducible and vastly versatile sensing capabilities of this easy-to-apply optomechanical sensor pad are demonstrated in the form of an optical pickup for acoustic instruments, a broadband optical accelerometer, and a biomedical vital sign sensor monitoring both respiration and pulse at the same time
    • …
    corecore