191 research outputs found
The disappearing screen: scenarios for audible interfaces
The world of ubiquitous computing, which by definition includes mobile devices of every kind, leads us to an era of small computer devices, usable in everyday situations. Computers are becoming smaller and operate discreetly in the background. This paper deals with the disappearance of the screen that is described and specified according to Lev Manovich. In doing research on radio frequency identification, this paper shows one possible way to interact with ubiquitous computers—primarily exploring suitability and scenarios for audible interfaces. The paper describes a research project of the University of Arts Berlin and the University of St. Gallen and proposes future research question
Lessons Learned from Establishing the Energy-Informatics Business Model: Case of a German Energy Company
Energy and utilities companies find themselves in a paradoxical situation in which their traditional business models are losing profitability, and they must advocate energy efficiency and climate-protection goals, and thus encourage their customers to save energy. As a result, they must partially cannibalize their business models and experiment with new models and techniques. Energy Informatics (EI) offers promising business opportunities that alleviate the concerns of energy companies about traditional revenue streams. However, recent discussions on this issue lack proof of concept and success determinants. This business case study fills this gap by describing the journey of German energy company Energiequelle, which established a sustainable business model based on EI. On the basis of our interview data, we analyzed Energiequelle’s EI strategy and stakeholder management and present six lessons learned. We believe that our practice-oriented research provides profound insight, especially to high-level executives and policymakers.DFG, 414044773, Open Access Publizieren 2019 - 2020 / Technische Universität Berli
Systematische Berufsfeldforschung und Weiterbildungsbedarf in den Creative Industries Berlin
SYSTEMATISCHE BERUFSFELDFORSCHUNG UND WEITERBILDUNGSBEDARF IN DEN CREATIVE INDUSTRIES BERLIN
Systematische Berufsfeldforschung und Weiterbildungsbedarf in den Creative Industries Berlin / Schildhauer, Thomas [Hrsg.] (Rights reserved) ( -
The influence of a weight-bearing platform on the mechanical behavior of two Ilizarov ring fixators: tensioned wires vs. half-pins
<p>Abstract</p> <p>Background</p> <p>A weight-bearing platform applied at the distal end of an Ilizarov external frame allows patients with hindfoot transfixations, foot deformities or plantar skin lesions to bear weight. This leads to an indirect loading of the fracture or osteotomy site. However, the effect on the fracture/osteotomy site's motion or compressive loads is unknown. The aim of this study was to analyze the mechanical effects of a weight-bearing platform on the traditional all-wire, four-ring frame in comparison to a two-ring frame consisting of half-pins.</p> <p>Methods</p> <p>Two frame configurations, with either anatomically positioned wires or half-pins, were analyzed with and without a weight-bearing platform applied underneath the distal ring. Composite tibiae with a mid-diaphyseal osteotomy of 3.5 mm were used in all the experiments. An axial load was applied with the use of a universal test machine (UTS<sup>®</sup>). Interfragmentary movements, the relative movements of bone fragments and movements between rings were recorded using displacement transducers. Compressive loads at the osteotomy site were recorded with loading cells.</p> <p>Results</p> <p>Indirect loading with a weight-bearing platform altered the force transmission through the osteotomy. Indirect loading of the tibiae decreased the extent of the axial micro-motion by 50% under the applied weight load when compared to direct weight loading (p < 0.05). The half pin frame was 25% stiffer than the wire frame under both direct and indirect loading of the tibiae (p < 0.05). Compressive loads under indirect loading were reduced by 67% in the wire frame and by 57% in the half-pin frames compared to direct loading of the bones (p < 0.05). While axial loading in the wire frames resulted in plain axial movements at the site of the osteotomy, it was coupled with translational movements and angular displacements in the half pin mountings. This effect was more apparent in the case of indirect loading.</p> <p>Conclusions</p> <p>A weight-bearing platform has substantial influence on the biomechanical performance of an Ilizarov external fixator. Half-pins induce greater stiffness to the Ilizarov external fixator and allow the usage of only one ring per bone segment, but shear stresses at the osteotomy under axial loading should be considered. The results allow an estimation of the size and direction of interfragmentary movements based on the extent of weight bearing.</p
Conversion From Knee Arthrodesis Back to Arthroplasty: A Particular Challenge in Combination With Fungal Periprosthetic Joint Infection.
A 58-year-old female treated at an outside facility with knee arthrodesis due to persistent periprosthetic joint infection fulfilled all prerequisites for a conversion back to arthroplasty, as part of a 2-stage revision. Owing to the detection of Candida parapsilosis, the treatment concept was converted to a three-stage procedure. A scheduled spacer exchange with additional amphotericin B-loaded polymethylmethacrylate was conducted as an intermediate revision before reimplantation. Conversion in the setting of fungal periprosthetic joint infection presents a challenge, and successful treatment hinges on the use of proper antifungal and antimicrobial protocols, advanced surgical techniques, and a multidisciplinary team approach. At the 3-year follow-up, successful infection eradication as measured by the Delphi-based consensus definition was achieved with a range of motion of 0°-100°
Trends in Spinal Surgery for Pott\u27s Disease (2000-2016): An Overview and Bibliometric Study.
Study Design: Systematic review.
Objectives: (1) What are the surgical indications? Have they changed over time since the year 2000? (2) What is the current surgical approaches of choice? Have they changed over time since the year 2000? Do they vary by geographical region? (3) What are the most common outcome measures following surgery?
Methods: Electronic databases and reference lists of key articles were searched from database inception from January 1, 2000 to December 31, 2016 to identify studies specifically evaluating surgical indications, current surgical approaches, and outcome measures for spinal tuberculosis.
Results: Six randomized controlled trials were identified from our search (1 excluded: no surgical arm identified after review) Neurological deficit, instability and deformity were common indications identified. Surgical approach included predominantly anterior for cervical spine and posterior for thoracic and lumbar spine. Combined approach was preferred in pediatric cases. Degree of deformity correction, neurological outcomes, and fusion formed the main bases of assessing surgical outcomes.
Conclusions: Majority of the current literature is from South Asia. The presence of neurological compromise, deformity, and instability were the primary criteria for surgical intervention. The preferred approach varied with the anatomical region of the spine in adults. Outcome measures predominantly involved deformity correction, neurological deficit, and fusion
Successful non-surgical management of pleuroparenchymal fistula following cervical intraspinal empyema
Pulmonary infections are life-threatening complications in patients with spinal cord injuries. In particular, paraplegic patients are at risk if they are ventilator-dependent. This case history refers to a spinal cord injury with a complete sensorimotor tetraplegia below C2 caused by a septic scattering of an intraspinal empyema at C2-C5 and T3-T4. A right-sided purulent pneumonia led to a complex lung infection with the formation of a pleuroparenchymal fistula. The manuscript describes successful, considerate, non-surgical management with shortterm separate lung ventilation. Treatment aimed to achieve the best possible result without additional harm. A variety of surgical and conservative strategies for the treatment of pleuroparenchymal fistula (PPF) have been described with different degrees of success. We detail the non-surgical management of a persistent PPF with temporary separate lung ventilation (SLV) via a double-lumen tube (DLT) in combination with talc pleurodesis as an approach in patients who are unable to undergo surgical treatment
- …