396 research outputs found

    Contemporary outcome measures in acute stroke research: choice of primary outcome measure

    Get PDF
    BACKGROUND AND PURPOSE: The diversity of available outcome measures for acute stroke trials is challenging and implies that the scales may be imperfect. To assist researchers planning trials and to aid interpretation, this article reviews and makes recommendations on the available choices of scales. The aim is to identify an approach that will be universally accepted and that should be included in most acute trials, without seeking to restrict options for special circumstances. METHODS: The article considers outcome measures that have been widely used or are currently advised. It examines desirable properties for outcome measures such as validity, relevance, responsiveness, statistical properties, availability of training, cultural and language issues, resistance to comorbidity, as well as potential weaknesses. Tracking and agreement among outcomes are covered. RESULTS: Typical ranges of scores for the common scales are described, along with their statistical properties, which in turn influence optimal analytic techniques. The timing of recovery on scores and usual practice in trial design are considered. CONCLUSIONS: The preferred outcome measure for acute trials is the modified Rankin Scale, assessed at 3 months after stroke onset or later. The interview should be conducted by a certified rater and should involve both the patient and any relevant caregiver. Incremental benefits at any level of the modified Rankin Scale may be acceptable. The modified Rankin Scale is imperfect but should be retained in its present form for comparability with existing treatment comparisons. No second measure should be required, but correlations with supporting scales may be used to confirm consistency in direction of effects on other measures

    Clinical review: Therapy for refractory intracranial hypertension in ischaemic stroke

    Get PDF
    The treatment of patients with large hemispheric ischaemic stroke accompanied by massive space-occupying oedema represents one of the major unsolved problems in neurocritical care medicine. Despite maximum intensive care, the prognosis of these patients is poor, with case fatality rates as high as 80%. Therefore, the term 'malignant brain infarction' was coined. Because conservative treatment strategies to limit brain tissue shift almost consistently fail, these massive infarctions often are regarded as an untreatable disease. The introduction of decompressive surgery (hemicraniectomy) has completely changed this point of view, suggesting that mortality rates may be reduced to approximately 20%. However, critics have always argued that the reduction in mortality may be outweighed by an accompanying increase in severe disability. Due to the lack of conclusive evidence of efficacy from randomised trials, controversy over the benefit of these treatment strategies remained, leading to large regional differences in the application of this procedure. Meanwhile, data from randomised trials confirm the results of former observational studies, demonstrating that hemicraniectomy not only significantly reduces mortality but also significantly improves clinical outcome without increasing the number of completely dependent patients. Hypothermia is another promising treatment option but still needs evidence of efficacy from randomised controlled trials before it may be recommended for clinical routine use. This review gives the reader an integrated view of the current status of treatment options in massive hemispheric brain infarction, based on the available data of clinical trials, including the most recent data from randomised trials published in 2007

    40 Gbit/s silicon-organic hybrid (SOH) phase modulator

    Get PDF
    A 40 Gbit/s electro-optic modulator is demonstrated. The modulator is based on a slotted silicon waveguide filled with an organic material. The silicon organic hybrid (SOH) approach allows combining highly nonlinear electro-optic organic materials with CMOS-compatible silicon photonics technology

    Silicon high-speed electro-optic modulator

    Get PDF
    A 40 Gbit/s electro-optic modulator is demonstrated. The modulator is based on a slotted silicon waveguide filled with a nonlinear organic material. A modulation voltage-length product of V π L = 0.21 Vcm can be achieved

    Endovascular equipoise shift in a phase III randomized clinical trial of sonothrombolysis for acute ischemic stroke

    Get PDF
    Background: Results of our recently published phase III randomized clinical trial of ultrasound-enhanced thrombolysis (sonothrombolysis) using an operator-independent, high frequency ultrasound device revealed heterogeneity of patient recruitment among centers. Methods: We performed a post hoc analysis after excluding subjects that were recruited at centers reporting a decline in the balance of randomization between sonothrombolysis and concurrent endovascular trials. Results: From a total of 676 participants randomized in the CLOTBUST-ER trial we identified 52 patients from 7 centers with perceived equipoise shift in favor of endovascular treatment. Post hoc sensitivity analysis in the intention-to-treat population adjusted for age, National Institutes of Health Scale score at baseline, time from stroke onset to tPA bolus and baseline serum glucose showed a significant (p <0.01) interaction of perceived endovascular equipoise shift on the association between sonothrombolysis and 3 month functional outcome [adjusted common odds ratio (cOR) in centers with perceived endovascular equipoise shift: 0.22, 95% CI 0.06-0.75; p = 0.02; adjusted cOR for centers without endovascular equipoise shift: 1.20, 95% CI 0.89-1.62; p = 0.24)]. After excluding centers with perceived endovascular equipoise shift, patients randomized to sonothrombolysis had higher odds of 3 month functional independence (mRS scores 0-2) compared with patients treated with tPA only (adjusted OR: 1.53; 95% CI 1.01-2.31; p = 0.04). Conclusion: Our experience in CLOTBUST-ER indicates that increasing implementation of endovascular therapies across major academic stroke centers raises significant challenges for clinical trials aiming to test noninterventional or adjuvant reperfusion strategies.Peer reviewe

    Identification of imaging selection patterns in acute ischemic stroke patients and the influence on treatment and clinical trial enrolment decision making

    Get PDF
    For the STroke Imaging Research (STIR) and VISTA-Imaging Investigators The purpose of this study was to collect precise information on the typical imaging decisions given specific clinical acute stroke scenarios. Stroke centers worldwide were surveyed regarding typical imaging used to work up representative acute stroke patients, make treatment decisions, and willingness to enroll in clinical trials. STroke Imaging Research and Virtual International Stroke Trials Archive-Imaging circulated an online survey of clinical case vignettes through its website, the websites of national professional societies from multiple countries as well as through email distribution lists from STroke Imaging Research and participating societies. Survey responders were asked to select the typical imaging work-up for each clinical vignette presented. Actual images were not presented to the survey responders. Instead, the survey then displayed several types of imaging findings offered by the imaging strategy, and the responders selected the appropriate therapy and whether to enroll into a clinical trial considering time from onset, clinical presentation, and imaging findings. A follow-up survey focusing on 6 h from onset was conducted after the release of the positive endovascular trials. We received 548 responses from 35 countries including 282 individual centers; 78% of the centers originating from Australia, Brazil, France, Germany, Spain, United Kingdom, and United States. The specific onset windows presented influenced the type of imaging work-up selected more than the clinical scenario. Magnetic Resonance Imaging usage (27-28%) was substantial, in particular for wake-up stroke. Following the release of the positive trials, selection of perfusion imaging significantly increased for imaging strategy. Usage of vascular or perfusion imaging by Computed Tomography or Magnetic Resonance Imaging beyond just parenchymal imaging was the primary work-up (62-87%) across all clinical vignettes and time windows. Perfusion imaging with Computed Tomography or Magnetic Resonance Imaging was associated with increased probability of enrollment into clinical trials for 0-3 h. Following the release of the positive endovascular trials, selection of endovascular only treatment for 6 h increased across all clinical vignettes

    Endovascular equipoise shift in a phase III randomized clinical trial of sonothrombolysis for acute ischemic stroke

    Get PDF
    Background: Results of our recently published phase III randomized clinical trial of ultrasound-enhanced thrombolysis (sonothrombolysis) using an operator-independent, high frequency ultrasound device revealed heterogeneity of patient recruitment among centers. Methods: We performed a post hoc analysis after excluding subjects that were recruited at centers reporting a decline in the balance of randomization between sonothrombolysis and concurrent endovascular trials. Results: From a total of 676 participants randomized in the CLOTBUST-ER trial we identified 52 patients from 7 centers with perceived equipoise shift in favor of endovascular treatment. Post hoc sensitivity analysis in the intention-to-treat population adjusted for age, National Institutes of Health Scale score at baseline, time from stroke onset to tPA bolus and baseline serum glucose showed a significant (p &lt; 0.01) interaction of perceived endovascular equipoise shift on the association between sonothrombolysis and 3 month functional outcome [adjusted common odds ratio (cOR) in centers with perceived endovascular equipoise shift: 0.22, 95% CI 0.06–0.75; p = 0.02; adjusted cOR for centers without endovascular equipoise shift: 1.20, 95% CI 0.89–1.62; p = 0.24)]. After excluding centers with perceived endovascular equipoise shift, patients randomized to sonothrombolysis had higher odds of 3 month functional independence (mRS scores 0–2) compared with patients treated with tPA only (adjusted OR: 1.53; 95% CI 1.01–2.31; p = 0.04). Conclusion: Our experience in CLOTBUST-ER indicates that increasing implementation of endovascular therapies across major academic stroke centers raises significant challenges for clinical trials aiming to test noninterventional or adjuvant reperfusion strategies
    corecore