111 research outputs found

    Isotropic-Nematic Transition in Liquid-Crystalline Elastomers

    Full text link
    In liquid-crystalline elastomers, the nematic order parameter and the induced strain vary smoothly across the isotropic-nematic transition, without the expected first-order discontinuity. To investigate this smooth variation, we measure the strain as a function of temperature over a range of applied stress, for elastomers crosslinked in the nematic and isotropic phases, and analyze the results using a variation on Landau theory. This analysis shows that the smooth variation arises from quenched disorder in the elastomer, combined with the effects of applied stress and internal stress.Comment: 4 pages, including 4 postscript figures, uses REVTeX

    In vitro tooth cleaning efficacy of electric toothbrushes around brackets

    Get PDF
    This in vitro study assessed the cleaning efficacy of different electric toothbrushes around upper incisor brackets. Standard and Mini Diamond™ brackets were fixed on black-stained teeth. The teeth were coated with white titanium oxide and brushed in a machine twice for 1 minute each. Twelve different brush heads with either a wiping or an oscillating-rotating action were tested. After brushing, the teeth were scanned, the black surfaces were assessed planimetrically and a modified plaque index for orthodontic patients (PIOP) was introduced. Tooth areas, which were black again after brushing indicated tooth surface contact of the filaments and were expressed as a percentage of total area. The remaining white areas around the brackets indicated 'plaque-retentive' niches. Analysis of variance was used for individual comparison of the brush types. Bonferroni/Dunn adjustment was applied for multiple testing. The Sonicare® toothbrush handle with the brush head 'Compact ProResults' (81.7 per cent) and the brush head 'Standard ProResults' (80.8 per cent), as well as the sonic Waterpik® toothbrush SR 800E with the standard brush head (78.2 per cent), showed statistically significantly better cleaning efficacy than all others. The poorest cleaning efficacy was observed for the oscillating-rotating Braun Oral-B Professional Care with the brush head 'Ortho' (less than 50 per cent). The planimetric findings were in correspondence with the results of the PIOP assessment. Cleaning efficacy of electric toothbrushes around brackets on upper incisors was different between the tested brushes. The PIOP was practicable, effective, and easy to use, although it has to be verified in a clinical stud

    Magnetic moment of welded HTS samples: dependence on the current flowing through the welds

    Full text link
    We present a method to calculate the magnetic moments of the high-temperature superconducting (HTS) samples which consist of a few welded HTS parts. The approach is generalized for the samples of various geometrical shapes and an arbitrary number of welds. The obtained relations between the sample moment and the density of critical current, which flows through the welds, allow to use the magnetization loops for a quantitative characterization of the weld quality in a wide range of temperatures and/or magnetic fields.Comment: RevTeX4, 4 pages, 2 figures. Submitted to Supercond. Sci. Techno

    Imaging local diffusion in microstructures using NV-based pulsed field gradient NMR

    Full text link
    Understanding diffusion in microstructures plays a crucial role in many scientific fields, including neuroscience, cancer or energy research. While magnetic resonance (MR) methods are the gold standard for diffusion measurements, spatial encoding in MR imaging has limitations. Here, we introduce nitrogen-vacancy (NV) center based nuclear magnetic resonance (NMR) spectroscopy as a powerful tool to probe diffusion with an optical readouts. We have developed an experimental scheme combining pulsed gradient spin echo (PGSE) with optically detected NV-NMR spectroscopy, which allows for the local quantification of molecular diffusion and flow within microscopic sample volumes. We demonstrate correlated optical imaging with spatially resolved PGSE NV-NMR experiments probing anisotropic water diffusion within a model microstructure. Our optically detected PGSE NV-NMR technique opens up prospects for extending the current capabilities of investigating diffusion processes with the future potential of probing single cells, tissue microstructures, or ion mobility in thin film materials for battery applications.Comment: 37 pages, 5 figures, 2 table

    FingerTac - A Wearable Tactile Thimble for Mobile Haptic Augmented Reality Applications

    Get PDF
    ingerTac is a novel concept for a wearable augmented haptic thimble. It makes use of the limited spatial discrimination capabilities of vibrotactile stimuli at the skin and generates tactile feedback perceived at the bottom center of a fingertip by applying simultaneous vibrations at both sides of the finger. Since the bottom of the finger is thus kept free of obstruction, the device is well promising for augmented haptic applications, where real world interactions need to be enriched or amalgamated with virtual tactile feedback. To minimize its lateral dimension, the vibration actuators are placed on top of the device, and mechanical links transmit the vibrations to the skin. Two evaluation studies with N=10 participants investigate (i) the loss of vibration intensity through these mechanical links, and (ii) the effect of lateral displacement between stimulus and induced vibration. The results of both studies support the introduced concept of the FingerTac

    Soft and non-soft structural transitions in disordered nematic networks

    Get PDF
    Properties of disordered nematic elastomers and gels are theoretically investigated with emphasis on the roles of non-local elastic interactions and crosslinking conditions. Networks originally crosslinked in the isotropic phase lose their long-range orientational order by the action of quenched random stresses, which we incorporate into the affine-deformation model of nematic rubber elasticity. We present a detailed picture of mechanical quasi-Goldstone modes, which accounts for an almost completely soft polydomain-monodomain (P-M) transition under strain as well as a ``four-leaf clover'' pattern in depolarized light scattering intensity. Dynamical relaxation of the domain structure is studied using a simple model. The peak wavenumber of the structure factor obeys a power-law-type slow kinetics and goes to zero in true mechanical equilibrium. The effect of quenched disorder on director fluctuation in the monodomain state is analyzed. The random frozen contribution to the fluctuation amplitude dominates the thermal one, at long wavelengths and near the P-M transition threshold. We also study networks obtained by crosslinking polydomain nematic polymer melts. The memory of initial director configuration acts as correlated and strong quenched disorder, which renders the P-M transition non-soft. The spatial distribution of the elastic free energy is strongly dehomogenized by external strain, in contrast to the case of isotropically crosslinked networks.Comment: 19 pages, 15 EPS figure

    Trueness of CAD/CAM digitization with a desktop scanner – an in vitro study

    Get PDF
    Desktop scanners are devices for digitization of conventional impressions or gypsum casts by indirect Computer-Aided Design/Computer-Assisted Manufacturing (CAD/CAM) in dentistry. The purpose of this in vitro study was: 1, to investigate whether virtual models produced by the extraoral scanner have the same trueness as sectioned casts; and 2, to assess if digitization with an extraoral scanner influences the surface information

    Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants:a systematic review and meta-analysis

    Get PDF
    Abstract Objectives The aim of this review was to systematically evaluate the failure rates of miniscrews related to their specific insertion site and explore the insertion site dependent risk factors contributing to their failure. Search methods An electronic search was conducted in the Cochrane Central Register of Controlled Trials (CENTRAL), Web of Knowledge, Scopus, MEDLINE and PubMed up to October 2017. A comprehensive manual search was also performed. Eligibility criteria Randomised clinical trials and prospective non-randomised studies, reporting a minimum of 20 inserted miniscrews in a specific insertion site and reporting the miniscrews’ failure rate in that insertion site, were included. Data collection and analysis Study selection, data extraction and quality assessment were performed independently by two reviewers. Studies were sub-grouped according to the insertion site, and the failure rates for every individual insertion site were analysed using a random-effects model with corresponding 95% confidence interval. Sensitivity analyses were performed in order to test the robustness of the reported results. Results Overall, 61 studies were included in the quantitative synthesis. Palatal sites had failure rates of 1.3% (95% CI 0.3–6), 4.8% (95% CI 1.6–13.4) and 5.5% (95% CI 2.8–10.7) for the midpalatal, paramedian and parapalatal insertion sites, respectively. The failure rates for the maxillary buccal sites were 9.2% (95% CI 7.4–11.4), 9.7% (95% CI 5.1–17.6) and 16.4% (95% CI 4.9–42.5) for the interradicular miniscrews inserted between maxillary first molars and second premolars and between maxillary canines and lateral incisors, and those inserted in the zygomatic buttress respectively. The failure rates for the mandibular buccal insertion sites were 13.5% (95% CI 7.3–23.6) and 9.9% (95% CI 4.9–19.1) for the interradicular miniscrews inserted between mandibular first molars and second premolars and between mandibular canines and first premolars, respectively. The risk of failure increased when the miniscrews contacted the roots, with a risk ratio of 8.7 (95% CI 5.1–14.7). Conclusions Orthodontic miniscrew implants provide acceptable success rates that vary among the explored insertion sites. Very low to low quality of evidence suggests that miniscrews inserted in midpalatal locations have a failure rate of 1.3% and those inserted in the zygomatic buttress have a failure rate of 16.4%. Moderate quality of evidence indicates that root contact significantly contributes to the failure of interradicular miniscrews placed between the first molars and second premolars. Results should be interpreted with caution due to methodological drawbacks in some of the included studies
    corecore