298 research outputs found

    A room temperature 19-channel magnetic field mapping device for cardiac signals

    Full text link
    We present a multichannel cardiac magnetic field imaging system built in Fribourg from optical double-resonance Cs vapor magnetometers. It consists of 25 individual sensors designed to record magnetic field maps of the beating human heart by simultaneous measurements on a grid of 19 points over the chest. The system is operated as an array of second order gradiometers using sophisticated digitally controlled feedback loops.Comment: 3 pages, 3 figures, submitted to Applied Physics Letter

    Satisfaction of patients on chronic haemodialysis and peritoneal dialysis

    Get PDF
    BACKGROUND: In contrast to quality of life, patient satisfaction on chronic haemodialysis (HD) and peritoneal dialysis (PD) has only rarely been studied. PATIENTS AND METHODS: All chronic HD and PD patients of the 19 centres located in western Switzerland were asked to complete a specific questionnaire, assessing dialysis centre characteristics, treatment modalities, and information received before and during dialysis treatment. Comparison between satisfaction with PD and HD was carried out on the patients in the nine centres offering both treatment modalities. RESULTS: Of the 558 questionnaires distributed to chronic HD patients, 455 were returned (response rate 82%). Fifty of 64 PD patients (78%) returned the questionnaire. The two groups were similar in age, gender, and duration of dialysis treatment. Completion rates were >90% for a majority of questions, with the lowest rate for information on sexuality (49% in HD and 54% in PD respectively). The lowest scores were recorded for information received about complications and costs of dialysis, and impact of end-stage kidney disease on sexuality. Satisfaction was lower in anonymous questionnaires. Satisfaction of PD patients was significantly better in 50% of the questions, particularly session tolerance (p<0.001), information about dialysis sessions (p=0.007), and complications (p=0.006). CONCLUSIONS: PD patients were on average more satisfied with their treatment than HD patients. Satisfaction could be improved with more information about potential adverse treatment effects

    Disease severity adversely affects delivery of dialysis in acute renal failure

    Get PDF
    Background/Aims: Methods of intermittent hemodialysis (IHD) dose quantification in acute renal failure (ARF) are not well defined. This observational study was designed to evaluate the impact of disease activity on delivered single pool Kt/V-urea in ARF patients. Methods: 100 patients with severe ARF (acute intrinsic renal disease in 18 patients, nephrotoxic acute tubular necrosis in 38 patients, and septic ARF in 44 patients) were analyzed during four consecutive sessions of IHD, performed for 3.5-5 h every other day or daily. Target IHD dose was a single pool Kt/V-urea of 1.2 or more per dialysis session for all patients. Prescribed Kt/V-urea was calculated from desired dialyzer clearance (K), desired treatment time (t) and anthropometric estimates for urea distribution volume (V). The desired clearance (K) was estimated from prescribed blood flow rate and manufacturer's charts of in vivo data obtained in maintenance dialysis patients. Delivered single pool Kt/V-urea was calculated using the Daugirdas equation. Results: None of the patients had prescription failure of the target dose. The delivered IHD doses were substantially lower than the prescribed Kt/V values, particularly in ARF patients with sepsis/septic shock. Stratification according to disease severity revealed that all patients with isolated ARF, but none with 3 or more organ failures and none who needed vasopressive support received the target dose. Conclusion: Prescription of target IHD dose by single pool Kt/V-urea resulted in suboptimal dialysis dose delivery in critically ill patients. Numerous patient-related and treatment-immanent factors acting in concert reduced the delivered dose. Copyright (C) 2007 S. Karger AG, Basel

    A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells

    Get PDF
    We have manufactured more than 250 nominally identical paraffin-coated Cs vapor cells (30 mm diameter bulbs) for multi-channel atomic magnetometer applications. We describe our dedicated cell characterization apparatus. For each cell we have determined the intrinsic longitudinal, \sGamma{01}, and transverse, \sGamma{02}, relaxation rates. Our best cell shows \sGamma{01}/2\pi\approx 0.5 Hz, and \sGamma{02}/2\pi\approx 2 Hz. We find a strong correlation of both relaxation rates which we explain in terms of reservoir and spin exchange relaxation. For each cell we have determined the optimal combination of rf and laser powers which yield the highest sensitivity to magnetic field changes. Out of all produced cells, 90% are found to have magnetometric sensitivities in the range of 9 to 30 fTHz. Noise analysis shows that the magnetometers operated with such cells have a sensitivity close to the fundamental photon shot noise limit

    « Paramétrer PMB pour les fanzines : réflexions et mise en place pour la Fanzinothèque genevoise »

    Get PDF
    As part of its ongoing projects, the Fanzinothèque genevoise (Zine Library of Geneva) has decided to set up a digital catalog to harmonize the cataloging of its collections, enable volunteers to create bibliographic records for newly-acquired fanzines, and make it easier for users to discover and search for documents. The aim here is to reflect on the specificities of cataloguing documents such as fanzines, taking into account both the need for simplification to make the task accessible to beginners, and the need for professionalism and interoperability between the various French-speaking zine libraries taking part in a common network

    Detection of testosterone administration based on the carbon isotope ratio profiling of endogenous steroids: international reference populations of professional soccer players

    Get PDF
    BACKGROUND AND OBJECTIVES: The determination of the carbon isotope ratio in androgen metabolites has been previously shown to be a reliable, direct method to detect testosterone misuse in the context of antidoping testing. Here, the variability in the 13C/12C ratios in urinary steroids in a widely heterogeneous cohort of professional soccer players residing in different countries (Argentina, Italy, Japan, South Africa, Switzerland and Uganda) is examined. METHODS: Carbon isotope ratios of selected androgens in urine specimens were determined using gas chromatography/combustion/isotope ratio mass spectrometry (GC-C-IRMS). RESULTS: Urinary steroids in Italian and Swiss populations were found to be enriched in 13C relative to other groups, reflecting higher consumption of C3 plants in these two countries. Importantly, detection criteria based on the difference in the carbon isotope ratio of androsterone and pregnanediol for each population were found to be well below the established threshold value for positive cases. CONCLUSIONS: The results obtained with the tested diet groups highlight the importance of adapting the criteria if one wishes to increase the sensitivity of exogenous testosterone detection. In addition, confirmatory tests might be rendered more efficient by combining isotope ratio mass spectrometry with refined interpretation criteria for positivity and subject-based profiling of steroids

    Renal replacement therapy in acute kidney injury: controversy and consensus

    Get PDF
    Renal replacement therapies (RRTs) represent a cornerstone in the management of severe acute kidney injury. This area of intensive care and nephrology has undergone significant improvement and evolution in recent years. Continuous RRTs have been a major focus of new technological and treatment strategies. RRT is being used increasingly in the intensive care unit, not only for renal indications but also for other organ-supportive strategies. Several aspects related to RRT are now well established, but others remain controversial. In this review, we review the available RRT modalities, covering technical and clinical aspects. We discuss several controversial issues, provide some practical recommendations, and where possible suggest a research agenda for the future

    Urinary analysis of four testosterone metabolites and pregnanediol by gas chromatography-combustion-isotope ratio mass spectrometry after oral administrations of testosterone.

    Get PDF
    The most frequently used method to demonstrate testosterone abuse is the determination of the testosterone and epitestosterone concentration ratio (T/E ratio) in urine. Nevertheless, it is known that factors other than testosterone administration may increase the T/E ratio. In the last years, the determination of the carbon isotope ratio has proven to be the most promising method to help discriminate between naturally elevated T/E ratios and those reflecting T use. In this paper, an excretion study following oral administration of 40 mg testosterone undecanoate initially and 13 h later is presented. Four testosterone metabolites (androsterone, etiocholanolone, 5 alpha-androstanediol, and 5 beta-androstanediol) together with an endogenous reference (5 beta-pregnanediol) were extracted from the urines and the delta(13)C/(12)C ratio of each compound was analyzed by gas chromatography-combustion-isotope ratio mass spectrometry. The results show similar maximum delta(13)C-value variations (parts per thousand difference of delta(13)C/(12)C ratio from the isotope ratio standard) for the T metabolites and concomitant changes of the T/E ratios after administration of the first and the second dose of T. Whereas the T/E ratios as well as the androsterone, etiocholanolone and 5 alpha-androstanediol delta(13)C-values returned to the baseline 15 h after the second T administration, a decrease of the 5 beta-androstanediol delta-values could be detected for over 40 h. This suggests that measurements of 5 beta-androstanediol delta-values allow the detection of a testosterone ingestion over a longer post-administration period than other T metabolites delta(13)C-values or than the usual T/E ratio approach

    Detection of exogenous GHB in blood by gas chromatography-combustion-isotope ratio mass spectrometry: implications in postmortem toxicology.

    Get PDF
    Because GHB (gamma-hydroxybutyrate) is present in both blood and urine of the general population, toxicologists must be able to discriminate between endogenous levels and a concentration resulting from exposure. In this paper, we propose a procedure for the detection of exogenous GHB in blood by gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS). Following liquid-liquid and solid-phase extractions, GHB is derivatized to GHB di-TMS before analysis by GC-C-IRMS. Significant differences in the carbon isotopic ratio (delta(13)C-values > 13.5 per thousand) were found between endogenous and synthetic GHB. Indeed, for postmortem blood samples with different GHB concentrations (range: 13.8-86.3 mg/L), we have obtained GHB delta(13)C-values ranging from -20.6 to -24.7 per thousand, whereas delta(13)C-values for the GHB from police seizure were in the range -38.2 to -50.2 per thousand. In contrast to the use of cut-off concentrations for positive postmortem blood GHB concentrations, this method should provide an unambiguous indication of the drug origin

    Celecoxib does not appear to affect prosthesis fixation in total knee replacement: A randomized study using radiostereometry in 50 patients

    Get PDF
    Background and purpose After joint replacement, a repair process starts at the interface between bone and cement. If this process is disturbed, the prosthesis may never become rigidly fixed to the bone, leading to migration—and with time, loosening. Cox-2 inhibitors are widely used as postoperative analgesics, and have adverse effects on bone healing. This could tamper prosthesis fixation. We investigated whether celecoxib, a selective Cox-2 inhibitor, increases prosthesis migration in total knee replacement (TKR)
    corecore