140 research outputs found

    Studies of an aspect of renal function with the aid of dynamic CT and renogram.

    Get PDF
    Dynamic CT scans were conducted on 94 persons who had been randomly selected among the patients and the volunteers. The test results were used to obtain the time-density curve. A part of the subjects (20 cases) underwent the renogram examination for the comparative studies. The cortico-aortic (CA) ratio derived from the time-density curve demonstrated good correlation between the dynamic CT and the renal function (r = 0.68). When the dynamic CT studies and the renogram were compared, the vascular phase of the renogram showed strong correlation with CA ratio. Consequently the dynamic CT study the CA ratio was believed to demonstrate the renal function.</p

    Identification of semen from criminal materials by means of paper chromatography--a forensic-medical study

    Get PDF
    In the present experiments attempts were made to identify semen from various specimens such as the semen itself, spots of semen on clothes, putrefied semen or semen contaminated with blood, menstrual blood, vaginal fluid, according to the techniques of LEVONEN. As the result it has been clarified that in every instance it is possible to isolate and detect the spots of choline by spraying Dragehdorff's reagent.</p

    Effect of Partial Ileal Bypass on Cholesterol and Bile Acid Metabolism in Rats

    Get PDF
    In order to clarify the effect of ileal bypass on cholesterol and bile acid metabolism, partial (20 cm) ileal bypass rats were fed a 2% cholesterol supplemented diet for a week after 4 weeks of the operation. The serum and liver cholesterol and phospholipid levels, biliary cholesterol, phospholipid and bile acid secretions, and fecal cholesterol, coprostanol and bile acid excretions were examined. The serum cholesterol level in ileal bypass rats was lower than in normal rats and no hypercholesterolemia was brought about in ileal bypass rats by feeding them the cholesterol diet. The liver cholesterol level increased by feeding the cholesterol diet even in ileal bypass rats but the increase was far less than that in normal rats (22% versus 57%). Biliary bile acid secretion decreased and fecal bile acid excretion increased markedly in ileal bypass rats. Deoxycholic acid increased remarkably in both bile and feces and resulted in an increase in the ratio of the sum of bile acids derived from cholic acid over the sum of bile acids derived from chenodeoxycholic acid (CA/CDCA ratio) in the feces. These results suggest that the absorption of bile acids is impaired, the pool size of bile acids decreases and the hepatic synthesis of bile acids, especially that of cholic acid, increases in ileal bypass rats. As a result, cholesterol feeding to ileal bypass rats produces neither hypercholesterolemia nor a further increase in bile acid synthesis

    Near-field light detection by conservative and dissipative force modulation methods using a piezoelectric cantilever

    Get PDF
    金沢大学フロンティアサイエンス機構We demonstrated near-field light detection by dynamic force microscope using a self-sensing piezoelectric cantilever having a lead zirconate titanate thin film layer. The cantilever tip was brought close to a glass plate with a patterned chromium film on a right angle prism. The backside of the prism was irradiated by an intensity modulated laser light to create an evanescent field at the glass surface. We obtained near-field optical images of the patterned glass by detecting the frequency shift modulation or the amplitude modulation induced by the near-field light while the tip-sample distance was regulated by the frequency modulation method in ambient condition. © 2010 American Institute of Physics

    [Pathophysiology]

    Get PDF

    Reliability of DWI and FLAIR for diagnosis of sporadic CJD

    Get PDF
    Objectives: To assess the utility of the display standardisation of diffusion-weighted MRI (DWI) and to compare the effectiveness of DWI and fluid-attenuated inversion recovery (FLAIR) MRI for the diagnosis of sporadic Creutzfeldte–Jakob disease (sCJD). Design: A reliability and agreement study. Setting: Thirteen MRI observers comprising eight neurologists and five radiologists at two universities in Japan. Participants: Data of 1.5-Tesla DWI and FLAIR were obtained from 29 patients with sCJD and 13 controls. Outcome measures: Standardisation of DWI display was performed utilising b0 imaging. The observers participated in standardised DWI, variable DWI (the display adjustment was observer dependent) and FLAIR sessions. The observers independently assessed each MRI for CJD-related lesions, that is, hyperintensity in the cerebral cortex or striatum, using a continuous rating scale. Performance was evaluated by the area under the receiver operating characteristics curve (AUC). Results: The mean AUC values were 0.84 (95% CI 0.81 to 0.87) for standardised DWI, 0.85 (95% CI 0.82 to 0.88) for variable DWI and 0.68 (95% CI 0.63 to 0.72) for FLAIR, demonstrating the superiority of DWI (p<0.05). There was a trend for higher intraclass correlations of standardised DWI (0.74, 95% CI 0.66 to 0.83) and variable DWI (0.72, 95% CI 0.62 to 0.81) than that of FLAIR (0.63, 95% CI 0.53 to 0.74), although the differences were not statistically significant. Conclusions: Standardised DWI is as reliable as variable DWI, and the two DWI displays are superior to FLAIR for the diagnosis of sCJD. The authors propose that hyperintensity in the cerebral cortex or striatum on 1.5-Tesla DWI but not FLAIR can be a reliable diagnostic marker for sCJD

    Multicentre multiobserver study of diffusion-weighted and fluid-attenuated inversion recovery MRI for the diagnosis of sporadic Creutzfeldt–Jakob disease: a reliability and agreement study

    Get PDF
    Objectives: To assess the utility of the display standardisation of diffusion-weighted MRI (DWI) and to compare the effectiveness of DWI and fluid-attenuated inversion recovery (FLAIR) MRI for the diagnosis of sporadic Creutzfeldt-Jakob disease (sCJD). Design: A reliability and agreement study. Setting: Thirteen MRI observers comprising eight neurologists and five radiologists at two universities in Japan. Participants: Data of 1.5-Tesla DWI and FLAIR were obtained from 29 patients with sCJD and 13 controls. Outcome measures: Standardisation of DWI display was performed utilising b0 imaging. The observers participated in standardised DWI, variable DWI (the display adjustment was observer dependent) and FLAIR sessions. The observers independently assessed each MRI for CJD-related lesions, that is, hyperintensity in the cerebral cortex or striatum, using a continuous rating scale. Performance was evaluated by the area under the receiver operating characteristics curve (AUC). Results: The mean AUC values were 0.84 (95% CI 0.81 to 0.87) for standardised DWI, 0.85 (95% CI 0.82 to 0.88) for variable DWI and 0.68 (95% CI 0.63 to 0.72) for FLAIR, demonstrating the superiority of DWI (p<0.05). There was a trend for higher intraclass correlations of standardised DWI (0.74, 95% CI 0.66 to 0.83) and variable DWI (0.72, 95% CI 0.62 to 0.81) than that of FLAIR (0.63, 95% CI 0.53 to 0.74), although the differences were not statistically significant. Conclusions: Standardised DWI is as reliable as variable DWI, and the two DWI displays are superior to FLAIR for the diagnosis of sCJD. The authors propose that hyperintensity in the cerebral cortex or striatum on 1.5-Tesla DWI but not FLAIR can be a reliable diagnostic marker for sCJD

    Early Detection of Abnormal Prion Protein in Genetic Human Prion Diseases Now Possible Using Real-Time QUIC Assay

    Get PDF
    Introduction: The definitive diagnosis of genetic prion diseases (gPrD) requires pathological confirmation. To date, diagnosis has relied upon the finding of the biomarkers 14-3-3 protein and total tau (t-tau) protein in the cerebrospinal fluid (CSF), but many researchers have reported that these markers are not sufficiently elevated in gPrD, especially in Gerstmann-Sträussler-Scheinker syndrome (GSS). We recently developed a new in vitro amplification technology, designated "real-time quaking-induced conversion (RT-QUIC)", to detect the abnormal form of prion protein in CSF from sporadic Creutzfeldt-Jakob disease (sCJD) patients. In the present study, we aimed to investigate the presence of biomarkers and evaluate RT-QUIC assay in patients with gPrD, as the utility of RT-QUIC as a diagnostic tool in gPrD has yet to be determined. Method/Principal Findings: 56 CSF samples were obtained from gPrD patients, including 20 cases of GSS with P102L mutation, 12 cases of fatal familial insomnia (FFI; D178N), and 24 cases of genetic CJD (gCJD), comprising 22 cases with E200K mutation and 2 with V203I mutation. We subjected all CSF samples to RT-QUIC assay, analyzed 14-3-3 protein by Western blotting, and measured t-tau protein using an ELISA kit. The detection sensitivities of RT-QUIC were as follows: GSS (78%), FFI (100%), gCJD E200K (87%), and gCJD V203I (100%). On the other hand the detection sensitivities of biomarkers were considerably lower: GSS (11%), FFI (0%), gCJD E200K (73%), and gCJD V203I (67%). Thus, RT-QUIC had a much higher detection sensitivity compared with testing for biomarkers, especially in patients with GSS and FFI. Conclusion/Significance: RT-QUIC assay is more sensitive than testing for biomarkers in gPrD patients. RT-QUIC method would thus be useful as a diagnostic tool when the patient or the patient\u27s family does not agree to genetic testing, or to confirm the diagnosis in the presence of a positive result for genetic testing
    corecore