3,147 research outputs found

    First results from an aging test of a prototype RPC for the LHCb Muon System

    Get PDF
    Recent results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge of about 0.45 C/cm2^2, corresponding to about 4 years of LHCb running at the highest background rate. The performance of the chamber has been studied under several photon flux values exploiting a muon beam. A degradation of the rate capability above 1 kHz/cm2^2 is observed, which can be correlated to a sizeable increase of resistivity of the chamber plates. An increase of the chamber dark current is also observed. The chamber performance is found to fulfill the LHCb operation requirements.Comment: 6 pages, 9 figures, presented at the International Workshop on Aging Phenomena in Gaseous Detectors'', DESY-Hamburg (Germany), October 200

    Front-end Electronics Test for the LHCb Muon Wire Chambers

    Get PDF
    This document describes the apparatus and procedures implemented to test Multi Wire Proportional Chambers (MWPC) after front-end assembly for the LHCb Muon Detector. Results of measurements of key noise parameters are also described. Given a fully equipped chamber, this system is able to diagnose every channel performing an analysis of front-end output drivers’ response and noise rate versus threshold. Besides, it allows to assess if the noise rate at the experiment threshold region is within appropriate limits. Aiming at an automatic, fast and user-friendly system for mass production tests of MWPC, the project has foreseen as well electronic identification of every chamber and front-end board, and data archiving in such a way to make it available to the Experiment Control System (ECS) while in operation

    New results from an extensive aging test on bakelite Resistive Plate Chambers

    Get PDF
    We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MOhm to more than 250 MOhm. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm2 to less than 0.15 kHz/cm2 is also found.Comment: 6 pages, 7 figures, presented at Siena 2002, 8th Topical Seminar on Innovative Particle and Radiation Detectors 21-24 October 2002, Siena, Ital

    Preliminary results of an aging test of RPC chambers for the LHCb Muon System

    Get PDF
    The preliminary results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge density of 0.42 C/cm^2, corresponding to about 4 years of LHCb running at the highest background rate. We observe a rise in the dark current and noise measured with source off. The current drawn with source on steadily decreased, possibly indicating an increase of resistivity of the chamber plates. The performance of the chamber, studied with a muon beam under several photon flux values, is found to still fulfill the LHCb operation requirements.Comment: 4 pages, 6 figures, presented at RPC2001, VIth Workshop on Resistive Plate Chambers and Related Detectors, November 26-27 2001, Coimbra, Portuga

    Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency

    Full text link
    A method is described which allows to deduce the dead-time of the front-end electronics of the LHCb muon detector from a series of measurements performed at different luminosities at a bunch-crossing rate of 20 MHz. The measured values of the dead-time range from 70 ns to 100 ns. These results allow to estimate the performance of the muon detector at the future bunch-crossing rate of 40 MHz and at higher luminosity

    Measurements of the Absolute Branching Ratios for the Dominant KL Decays, the KL Lifetime, and Vus with the KLOE Detector

    Full text link
    From a sample of about 10^9 Phi mesons produced at DAFNE, we have selected KL mesons tagged by observing KS->pi+pi- decays. We present results on the major KL branching ratios, including those of the semileptonic decays needed for the determination of Vus. These branching ratio measurements are fully inclusive with respect to final-state radiation. The KL lifetime has also been measured.Comment: Submitted to Phys. Lett.

    Measurement of the branching fraction for the decay KS --> pi e nu

    Full text link
    We present a measurement of the branching ratio BR(KS --> pi e nu) performed using the KLOE detector. KS mesons are produced in the reaction e+ e- --> phi --> KS KL at the DAFNE collider. In a sample of about 5 million KS-tagged events we find 624 +- 30 semileptonic KS decays. Normalizing to the KS --> pi+ pi- count in the same data sample, we obtain BR(KS --> pi e nu) = (6.91 +- 0.37) 10^-4, in agreement with the Standard Model expectation.Comment: 9 pages, 5 Encapsulated Postscript figures. Submitted to Phys. Lett.

    Study of the Decay phi --> eta pi0 gamma with the KLOE detector

    Full text link
    In a sample of 5.3x10^7 phi-decays observed with the KLOE detector at the Frascati phi-factory Dafne we find 605 eta pi0 gamma events with eta --> gamma\gamma and 197 eta pi0 gamma events with eta --> pi+ pi- pi0. The decay phi --> eta pi0 gamma is dominated by the process phi --> a0 gamma. From a fit to the eta pi0 mass spectrum we find BR(phi --> ao(980) gamma)= (7.4 +- 0.7)x10^-5.Comment: 12 pages, 6 figures, submitted to Phys.Lett.

    Determination of CP and CPT violation parameters in the neutral kaon system using the Bell-Steinberger relation and data from the KLOE experiment

    Get PDF
    We present an improved determination of the CP and CPT violation parameters Re(epsilon) and Im(delta) based on the unitarity condition (Bell-Steinberger relation) and on recent results from the KLOE experiment. We find Re(epsilon) = (159.6 \pm 1.3)10^-5 and Im(delta) = (0.4 \pm 2.1)10^-5, consistent with no CPT violation.Comment: Submitted to JHE
    corecore