88 research outputs found

    Anterior knee pain after total knee arthroplasty: does it correlate with patellar blood flow?

    Get PDF
    Purpose: Total knee arthroplasty (TKA) disturbs patellar blood flow, an unintended accompaniment to TKA that may be a cause of postoperative anterior knee pain. We examine whether disrupted patellar blood flow correlates with anterior knee pain following TKA. Methods: In 50 patients (21 men, 29 women) undergoing TKA, we compared patellar blood flow at flexions 0° to 30°, 60°, 90°, and 110° before and after medial parapatellar arthrotomy to pre- and postoperative anterior knee pain scores by means of a laser Doppler flowmeter (LDF) probe. Anterior knee pain was assessed using the pain intensity numeric rating scale (NRS) of 0-10 (0-no, 10-worst pain). Based on the NRS pain values, patients were divided into two main groups: group A (n=34) with no pain or discomfort (NRS range 0-4) and group B (n=16) with anterior knee pain (NRS range 5-10). Results: Patients of group B demonstrated a significant decrease in blood flow before arthrotomy at flexions from 0° to 90°, and 110° and from 0° to 60°, 90°, and 110° after arthrotomy. For group A, a significant decrease in blood flow was detected at flexions from 0° to 90°, and 110° before and after arthrotomy. For both groups, medial arthrotomy did not have a statistically significant influence on patellar blood flow (margin of significance P<0.05). Prior to TKA, 16 of the 50 patients of group B (32%) complained of anterior knee pain (mean NRS 7.1±1.7). At 2-year follow-up, pain significantly decreased (NRS 3.1±2.1) and only 4 of the 16 patients (25%) complained of moderate anterior pain (average NRS 5.7±0.5), while 8 of 16 (50%) patients reported discomfort (mean NRS 3.5±1.8) around the patella. Patients in group A also demonstrated a significant decrease in pain intensity (from NRS 1.5±1.4 preoperatively to NRS 0.4±1.5 at 2-year follow-up). Statistical analysis demonstrated no statistically significant correlation between pre-arthrotomy/post-arthrotomy patellar blood flow and the presence of preoperative and postoperative anterior knee pain. Only the degree of flexion had an influence on patellar blood flow. Conclusion: Medial arthrotomy had no direct significant effect on patellar blood flow, and the diminished blood flow did not correlate with postoperative anterior knee pain. However, a significant correlation was revealed between patellar blood flow and the degree of flexion: in almost a quarter of patients, blood flow dropped to zero at flexions of 100° and above. Level of evidence: I

    Anterior crucial ligament rupture: self-healing through dynamic intraligamentary stabilization technique

    Get PDF
    Purpose: Surgery involving arthroscopic reconstruction of the injured ligament is the gold standard treatment for torn anterior cruciate ligament (ACL). Recent studies support the hypothesis of biological self-healing of ruptured ACL. The aim of the study is to evaluate, in an animal model, the efficacy of a new technique, dynamic intraligamentary stabilization that utilizes biological self-healing for repair of acute ACL ruptures. Methods: The ACL in 11 adult female white alpine sheep was transected and in 8 sheep reconstructed by dynamic intraligamentary stabilization. To enhance the healing potential, microfracturing and collagen were used in all animals. The contralateral, non-operated knees served as controls. At 3months postkilling, all animals were submitted to magnetic resonance imaging and biomechanical and histological evaluation. Results: No surgery-related complications were observed. Postoperatively, all animals regularly used the operated leg with full weight bearing and no lameness. At the time of killing, all animals exhibited radiological and histological healing of the transacted ACL. Biomechanical tests confirmed successful restoration of anteroposterior translation in the dynamic intraligamentary stabilization knees. Histological examination revealed dense scar tissue at the ends of the transected ligaments exhibiting hypercellularity and hypervascularization. Conclusion: The dynamic intraligamentary stabilization technique successfully induced self-healing of ruptured ACL in a sheep model. Knee joints remained stable during the healing period allowing free range of motion and full weight bearing, and no signs of osteoarthritis or other intraarticular damage in the follow up were observe

    Adjustable loop ACL suspension devices demonstrate less reliability in terms of reproducibility and irreversible displacement.

    Get PDF
    PURPOSE The aim of this study was to perform a comprehensive biomechanical examination of frequently applied femoral cortical suspension devices, comparing the properties of both fixed and adjustable fixation mechanisms. It was hypothesized that adjustable loop devices demonstrate less consistent fixation properties with increased variability compared to fixed loop devices. METHODS Nine frequently applied fixation button types were tested, six adjustable and three rigid loop devices. Six samples of each device type were purchased. Each device was installed in a servo-hydraulic mechanical testing machine, running a 2000 cycle loading protocol at force increments between 50 and 500 N. Irreversible displacement in mm was measured for all of the tested samples of each implant. Ultimately, maximum load to failure was applied and measured in Nm. An irreversible displacement of 3 mm was considered failure of the implant. RESULTS Three of the six adjustable devices (GraftMax™, TightRope® ToggleLoc™) demonstrated a median displacement above the threshold of clinical failure before completion of the cycles. All adjustable loop devices showed a wide intragroup variation in terms of irreversible displacement, compared to fixed-loop devices. Fixed-loop devices provided consistent reproducible results with narrow ranges and significantly lower irreversible displacement (p < 0.05), the maximum being 1.4 mm. All devices withstood an ultimate force of more than 500 N. CONCLUSION Adjustable loop devices still show biomechanical inferiority and demonstrate heterogeneity of fixation properties with wide- and less-reproducible displacement ranges resultant to the mechanism of adjustment, denoting less reliability. However, three adjustable devices (RIGIDLOOP™ Adjustable, Ultrabutton ◊, ProCinch™) demonstrate fixation capacities within the margins of clinical acceptance. RIGIDLOOP™ Adjustable provides the most comparable fixation properties to fixed loop devices

    The Hundred Most-Cited Publications in Orthopaedic Knee Research

    Get PDF
    BACKGROUND: Despite its limitations, citation analysis remains one of the best currently available tools for quantifying the impact of articles. Bibliometric studies list the "best-sellers" in a single location, and they have been published frequently in many fields during recent years. The purpose of the present study was to report the qualities and characteristics of citation classics in orthopaedic knee research. METHODS: The database of the Institute for Scientific Information (ISI) was utilized for identification of articles published from 1945 to March 2014. All knee articles that had been published in sixty-five orthopaedic and twenty-nine rheumatology journals and that had been cited at least 200 times were identified. The top 100 were selected for further analysis of authorship, source journal, number of citations, citation rate (both since publication and in 2013), geographic origin, article type, and level of evidence. RESULTS: The publication dates of the 100 most-cited articles ranged from 1948 to 2007, with the greatest number of articles published in the 1980s. Citations per article ranged from 2640 to 287. All articles were published in eleven of the ninety-four journals. The leading countries of origin were the U.S. followed by the U.K. and Sweden. The two main focus areas were sports traumatology and degenerative disease. The number of citations per article was also greatest for articles published in the 1980s. Basic research articles were cited more quickly, but not more often, than clinical articles. Most articles represented Level-IV evidence, followed by Levels II, III, and I. CONCLUSIONS: This bibliometric study is likely to include a list of intellectual milestones in orthopaedic knee research. It is apparent that a high level of evidence is not mandatory for an article to gain a large number of citations. Bibliometric reports provide a reflection of the quality of cited research published in a specific field and should therefore provoke thinking within the scientific community

    Phylogenomic Perspective on a Unique Mycobacterium bovis Clade Dominating Bovine Tuberculosis Infections among Cattle and Buffalos in Northern Brazil.

    Get PDF
    Lack of routine surveillance in countries endemic for bovine tuberculosis (TB) and limited laboratory support contributes to the inability to differentiate the Mycobacterium tuberculosis Complex species, leading to an underestimated burden of the disease. Here, Whole-Genome Sequencing of Mycobacterium bovis isolated from tissues with TB-like lesions obtained from cattle and buffalos at Marajó Island, Brazil, demonstrates that recent transmission of M. bovis is ongoing at distinct sites. Moreover, the M. bovis epidemiology in this setting is herein found to be dominated by an endemic and unique clade composed of strains evolved from a common ancestor that are now genetically differentiated from other M. bovis clades. Additionally, envisioning a rapid strain differentiation and tracing across multiple settings, 28 globally validated strain-specific SNPs were identified, three of which considered as robust markers for the M. bovis Marajó strain. In conclusion, this study contributes with data regarding the identification of a novel M. bovis phylogenetic clade responsible for ongoing transmission events in both cattle and buffalo species in Brazil, provides a framework to investigate the dissemination of this highly prevalent strain and, holds the potential to inform TB control strategies that may help to prevent the spread of bovine and zoonotic TB
    corecore