9 research outputs found

    Combining in vitro protein detection and in vivo antibody detection identifies potential vaccine targets against Staphylococcus aureus during osteomyelitis

    Get PDF
    Currently, little is known about the in vivo human immune response against Staphylococcus aureus during a biofilm-associated infection, such as osteomyelitis, and how this relates to protein production in biofilms in vitro. Therefore, we characterized IgG responses in 10 patients with chronic osteomyelitis against 50 proteins of S. aureus, analyzed the presence of these proteins in biofilms of the infecting isolates on polystyrene (PS) and human bone in vitro, and explored the relation between in vivo and in vitro data. IgG levels against 15 different proteins were significantly increased in patients compared to healthy controls. Using a novel competitive Luminex-based assay, eight of these proteins [alpha toxin, Staphylococcus aureus formyl peptide receptor-like 1 inhibitor (FlipR), glucosaminidase, iron-responsive surface determinants A and H, the putative ABC transporter SACOL0688, staphylococcal complement inhibitor (SCIN), and serine–aspartate repeat-containing protein E (SdrE)] were also detected in a majority of the infecting isolates during biofilm formation in vitro. However, 4 other proteins were detected in only a minority of isolates in vitro while, vice versa, 7 proteins were detected in multiple isolates in vitro but not associated with significantly increased IgG levels in patients. Detection of proteins was largely confirmed using a transcriptomic approach. Our data provide further insights into potential therapeutic targets, such as for vaccination, to reduce S. aureus virulence and biofilm formation. At the same time, our data suggest that either in vitro or immunological in vivo data alone should be interpreted cautiously and that combined studies are necessary to identify potential targets

    FK506 protects against articular cartilage collagenous extra-cellular matrix degradation

    Get PDF
    Objective: Osteoarthritis (OA) is a non-rheumatologic joint disease characterized by progressive degeneration of the cartilage extra-cellular matrix (ECM), enhanced subchondral bone remodeling, activation of synovial macrophages and osteophyte growth. Inhibition of calcineurin (Cn) activity through tacrolimus (FK506) in invitro monolayer chondrocytes exerts positive effects on ECM marker expression. This study therefore investigated the effects of FK506 on anabolic and catabolic markers of osteoarthritic chondrocytes in 2D and 3D invitro cultures, and its therapeutic effects in an invivo rat model of OA. Methods: Effects of high and low doses of FK506 on anabolic (QPCR/histochemistry) and catabolic (QPCR) markers were evaluated invitro on isolated (2D) and ECM-embedded chondrocytes (explants, 3D pellets). Severe cartilage damage was induced unilaterally in rat knees using papain injections in combination with a moderate running protocol. Twenty rats were treated with FK506 orally and compared to twenty untreated controls. Subchondral cortical and trabecular bone changes (longitudinal microCT) and macrophage activation (SPECT/CT) were measured. Articular cartilage was analyzed exvivo using contrast enhanced microCT and histology. Results: FK506 treatment of osteoarthritic chondrocytes invitro induced anabolic (mainly collagens) and reduced catabolic ECM marker expression. In line with this, FK506 treatment clearly protected ECM integrity invivo by markedly decreasing subchondral sclerosis, less development of subchondral pores, depletion of synovial macrophage activation and lower osteophyte growth. Conclusion: FK506 protected cartilage matrix integrity invitro and invivo. Additionally, FK506 treatment invivo reduced OA-like responses in different articular joint tissues and thereby makes Cn an interesting target for therapeutic intervention of OA

    In vivo pharmacokinetics of celecoxib loaded endcapped PCLA-PEG-PCLA thermogels in rats after subcutaneous administration

    No full text
    Injectable thermogels based on poly(ε-caprolactone-co-lactide)-b-poly(ethylene glycol)-b-poly(ε-caprolactone-co-lactide) (PCLA-PEG-PCLA) containing an acetyl- or propyl endcap and loaded with celecoxib were developed for local drug release. The aim of this study was to determine the effects of the composition of the celecoxib/PCLA-PEG-PCLA formulation on their in vivo drug release characteristics. Furthermore, we want to obtain insight into the in vitro-in vivo correlation. Different formulations were injected subcutaneously in rats and blood samples were taken for a period of 8 weeks. Celecoxib half-life in blood increased from 5 h for the bolus injection of celecoxib to more than 10 days for the slowest releasing gel formulation. Sustained release of celecoxib was obtained for at least 8 weeks after subcutaneous administration. The release period was prolonged from 3 to 6-8 weeks by increasing the injected volume from 100 to 500 µL, which also led to higher serum concentrations in time. Propyl endcapping of the polymer also led to a prolonged release compared to the acetyl endcapped polymer (49 versus 21 days) and at equal injected dose of the drug in lower serum concentrations. Increasing the celecoxib loading from 10 mg/mL to 50 mg/mL surprisingly led to prolonged release (28 versus 56 days) as well as higher serum concentrations per time point, even when corrected for the higher dose applied. The in vivo release was about twice as fast compared to the in vitro release for all formulations. Imaging of organs of mice, harvested 15 weeks after subcutaneous injection with polymer solution loaded with infrared-780 labelled dye showed no accumulation in any of these harvested organs except for traces in the kidneys, indicating renal clearance. Due to its simplicity and versatility, this drug delivery system has great potential for designing an injectable to locally treat osteoarthritis, and to enable tuning the gel to meet patient-specific needs

    In vivo pharmacokinetics of celecoxib loaded endcapped PCLA-PEG-PCLA thermogels in rats after subcutaneous administration

    No full text
    Injectable thermogels based on poly(ε-caprolactone-co-lactide)-b-poly(ethylene glycol)-b-poly(ε-caprolactone-co-lactide) (PCLA-PEG-PCLA) containing an acetyl- or propyl endcap and loaded with celecoxib were developed for local drug release. The aim of this study was to determine the effects of the composition of the celecoxib/PCLA-PEG-PCLA formulation on their in vivo drug release characteristics. Furthermore, we want to obtain insight into the in vitro-in vivo correlation. Different formulations were injected subcutaneously in rats and blood samples were taken for a period of 8 weeks. Celecoxib half-life in blood increased from 5 h for the bolus injection of celecoxib to more than 10 days for the slowest releasing gel formulation. Sustained release of celecoxib was obtained for at least 8 weeks after subcutaneous administration. The release period was prolonged from 3 to 6–8 weeks by increasing the injected volume from 100 to 500 µL, which also led to higher serum concentrations in time. Propyl endcapping of the polymer also led to a prolonged release compared to the acetyl endcapped polymer (49 versus 21 days) and at equal injected dose of the drug in lower serum concentrations. Increasing the celecoxib loading from 10 mg/mL to 50 mg/mL surprisingly led to prolonged release (28 versus 56 days) as well as higher serum concentrations per time point, even when corrected for the higher dose applied. The in vivo release was about twice as fast compared to the in vitro release for all formulations. Imaging of organs of mice, harvested 15 weeks after subcutaneous injection with polymer solution loaded with infrared-780 labelled dye showed no accumulation in any of these harvested organs except for traces in the kidneys, indicating renal clearance. Due to its simplicity and versatility, this drug delivery system has great potential for designing an injectable to locally treat osteoarthritis, and to enable tuning the gel to meet patient-specific needs

    In vivo pharmacokinetics of celecoxib loaded endcapped PCLA-PEG-PCLA thermogels in rats after subcutaneous administration

    No full text
    Injectable thermogels based on poly(ε-caprolactone-co-lactide)-b-poly(ethylene glycol)-b-poly(ε-caprolactone-co-lactide) (PCLA-PEG-PCLA) containing an acetyl- or propyl endcap and loaded with celecoxib were developed for local drug release. The aim of this study was to determine the effects of the composition of the celecoxib/PCLA-PEG-PCLA formulation on their in vivo drug release characteristics. Furthermore, we want to obtain insight into the in vitro-in vivo correlation. Different formulations were injected subcutaneously in rats and blood samples were taken for a period of 8 weeks. Celecoxib half-life in blood increased from 5 h for the bolus injection of celecoxib to more than 10 days for the slowest releasing gel formulation. Sustained release of celecoxib was obtained for at least 8 weeks after subcutaneous administration. The release period was prolonged from 3 to 6-8 weeks by increasing the injected volume from 100 to 500 µL, which also led to higher serum concentrations in time. Propyl endcapping of the polymer also led to a prolonged release compared to the acetyl endcapped polymer (49 versus 21 days) and at equal injected dose of the drug in lower serum concentrations. Increasing the celecoxib loading from 10 mg/mL to 50 mg/mL surprisingly led to prolonged release (28 versus 56 days) as well as higher serum concentrations per time point, even when corrected for the higher dose applied. The in vivo release was about twice as fast compared to the in vitro release for all formulations. Imaging of organs of mice, harvested 15 weeks after subcutaneous injection with polymer solution loaded with infrared-780 labelled dye showed no accumulation in any of these harvested organs except for traces in the kidneys, indicating renal clearance. Due to its simplicity and versatility, this drug delivery system has great potential for designing an injectable to locally treat osteoarthritis, and to enable tuning the gel to meet patient-specific needs

    In vivo pharmacokinetics of celecoxib loaded endcapped PCLA-PEG-PCLA thermogels in rats after subcutaneous administration

    No full text
    Injectable thermogels based on poly(ε-caprolactone-co-lactide)-b-poly(ethylene glycol)-b-poly(ε-caprolactone-co-lactide) (PCLA-PEG-PCLA) containing an acetyl- or propyl endcap and loaded with celecoxib were developed for local drug release. The aim of this study was to determine the effects of the composition of the celecoxib/PCLA-PEG-PCLA formulation on their in vivo drug release characteristics. Furthermore, we want to obtain insight into the in vitro-in vivo correlation. Different formulations were injected subcutaneously in rats and blood samples were taken for a period of 8 weeks. Celecoxib half-life in blood increased from 5 h for the bolus injection of celecoxib to more than 10 days for the slowest releasing gel formulation. Sustained release of celecoxib was obtained for at least 8 weeks after subcutaneous administration. The release period was prolonged from 3 to 6-8 weeks by increasing the injected volume from 100 to 500 µL, which also led to higher serum concentrations in time. Propyl endcapping of the polymer also led to a prolonged release compared to the acetyl endcapped polymer (49 versus 21 days) and at equal injected dose of the drug in lower serum concentrations. Increasing the celecoxib loading from 10 mg/mL to 50 mg/mL surprisingly led to prolonged release (28 versus 56 days) as well as higher serum concentrations per time point, even when corrected for the higher dose applied. The in vivo release was about twice as fast compared to the in vitro release for all formulations. Imaging of organs of mice, harvested 15 weeks after subcutaneous injection with polymer solution loaded with infrared-780 labelled dye showed no accumulation in any of these harvested organs except for traces in the kidneys, indicating renal clearance. Due to its simplicity and versatility, this drug delivery system has great potential for designing an injectable to locally treat osteoarthritis, and to enable tuning the gel to meet patient-specific needs

    Release behavior and intra-articular biocompatibility of celecoxib-loaded acetyl-capped PCLA-PEG-PCLA thermogels

    No full text
    In this study, we investigated the in vitro and in vivo properties and performance of a celecoxib-loaded hydrogel based on a fully acetyl-capped PCLA-PEG-PCLA triblock copolymer. Blends of different compositions of celocoxib, a drug used for pain management in osteoarthritis, and the acetyl-capped PCLA-PEG-PCLA triblock copolymer were mixed with buffer to yield temperature-responsive gelling systems. These systems containing up to 50 mg celecoxib/g gel, were sols at room temperature and converted into immobile gels at 37 °C. In vitro, release of celecoxib started after a ∼10-day lag phase followed by a sustained release of ∼90 days. The release was proven to be mediated by polymer dissolution from the gels. In vivo (subcutaneous injection in rats) experiments showed an initial celecoxib release of ∼30% during the first 3 days followed by a sustained release of celecoxib for 4-8 weeks. The absence of a lag phase and the faster release seen in vivo were likely due to the enhanced celecoxib solubility in biological fluids and active degradation of the gel by macrophages. Finally, intra-articular biocompatibility of the 50 mg/g celecoxib-loaded gel was demonstrated using μCT-scanning and histology, where no cartilage or bone changes were observed following injection into the knee joints of healthy rats. In conclusion, this study shows that celecoxib-loaded acetyl-capped PCLA-PEG-PCLA hydrogels form a safe drug delivery platform for sustained intra-articular release
    corecore