12 research outputs found

    Dizajn maske za lice s UVC-LED zračenjem i njezina djelotvornost protiv uobičajenih klica

    Get PDF
    During the Covid-19 pandemic, one of the best means of personal protection was using face masks. In this context, the World Health Organization has declared the attempts to produce masks inactivating airborne virus species a welcome initiative. This preliminary study aimed to prove that airborne germs passing through a mask filter cartridge can be destroyed by the rays emitted from UVC LEDs placed in such cartridge. We therefore designed such a face mask and tested the efficiency of UVC LEDs placed in its cartridge against common contaminants, gram-positive Staphylococcus aureus, gram-negative Pseudomonas aeruginosa, and the influenza A/Puerto Rico/8/1934 virus because of its similarity with SARS CoV-2. Eight UVC LEDs with a total power of 75 mW provided sufficient germicidal effect for all three germs. In terms of safety, ozone production released during UVC LED emission was negligible. Our findings are promising, as they show that well-designed UVC-based face masks can be effective against airborne germs, but further research on a greater sample may help us learn more and optimise such face masks.Tijekom pandemije Covida-19 jedan od najboljih oblika osobne zaštite bilo je nošenje maski za lice. U tom je smislu Svjetska zdravstvena organizacija pozdravila pokušaje izrade maski koje ubijaju virusne vrste koje se prenose zrakom. Cilj je ovoga preliminarnog istraživanja bio dokazati da se zrakom nošene klice koje prolaze kroz filtarske uloške mogu uništiti zračenjem UVC ledica smještenih u takve uloške. Stoga smo osmislili masku za lice s tom namjenom i iskušali djelotvornost UVC ledica protiv uobičajenih izvora zaraza: gram-pozitivnoga Staphylococcus aureus, gram-negativnoga Pseudomonas aeruginosa i virusa influence A/Puerto Rico/8/1934 zbog njegove sličnosti s virusom SARS CoV-2. Osam UVC ledica ukupne snage 75 mW iskazale su dovoljan germicidni učinak protiv svih triju klica. U smislu sigurnosti primjene, ozon proizveden tijekom UVC-LED zračenja pokazao se zanemarivim. Naši su rezultati obećavajući jer pokazuju da dobro osmišljene maske za lice s UVC zračenjem mogu biti djelotvorne protiv zrakom nošenih klica, ali će tek daljnja istraživanja na većem uzorku pomoći da doznamo više i usavršimo takve maske za lice

    MiR-221 as a Pre- and Postoperative Plasma Biomarker for Larynx Cancer Patients

    No full text
    Objective: In order to identify a plasma microRNA (miRNA) signature of larynx cancer (LCa), we examined miRNAs profile of plasma samples obtained from 30 LCa patients (preoperative and postoperative serum samples) and 30 healthy controls

    Revealing the functions of novel mutations in RAB3GAP1 in Martsolf and Warburg micro syndromes

    No full text
    Purpose: Martsolf (MS) and Warburg micro syndromes (WARBM) are rare autosomal recessive inherited allelic disorders, which share similar clinical features including microcephaly, intellectual disability, brain malformations, ocular abnormalities, and spasticity. Here, we revealed the functions of novel mutations in RAB3GAP1 in a Turkish female patient with MS and two siblings with WARBM. We also present a review of MS patients as well as all reported RAB3GAP1 pathogenic mutations in the literature. Methods: We present a female with MS phenotype and two siblings with WARBM having more severe phenotypes. We utilized whole-exome sequencing to identify the molecular basis of these syndromes and confirmed suspected variants by Sanger sequencing. Quantitative (q) RT-PCR analysis was carried out to reveal the functions of novel splice site mutation detected in MS patient. Results: We found a novel homozygous c.2607-1G>C splice site mutation in intron 22 of RAB3GAP1 in MS patient and a novel homozygous c.2187_2188delinsCT, p.(Met729_Lys730delinsIleTer) mutation in exon 19 of RAB3GAP1 in the WARBM patients. We showed exon skipping in MS patient by Sanger sequencing and gel electrophoresis. qRT-PCR analysis demonstrated the reduced expression of RAB3GAP1 in the patient with the c.2607-1G>C splice site mutation compared to a healthy control individual. Conclusion: Here, we have studied two novel RAB3GAP1 mutations in two different phenotypes; a MS associated novel splice site mutation, and a WARBM1 associated novel deletion-insertion mutation. Our findings suggest that this splice site mutation is responsible for milder phenotype and the deletion-insertion mutation presented here is associated with severe phenotype

    Periodic Evaluation of Anti-SARS-CoV-2 Antibody Levels and Determination of Surrogate Virus Neutralization in Healthcare Workers with COVID-19

    No full text
    Since its first detection in Wuhan, China, in December 2019, coronavirus disease-2019 (COVID-19) has turned into a pandemic, causing high rate of death and economic losses worldwide. Severe acut respiratory syndrome coronavirus-2 (SARS-CoV-2) is a zoonotic, positive-polar RNA virus and initiates an immune response that targets proteins involved in viral infection and replication and includes the production of neutralizing antibodies. Antibodies remain detectable in the plasma for months, binding to virus antigens quickly and strongly and they block infiltration and replication. The detection of total antibody and virus neutralization provides clues about the severity of the disease and the risk of reinfection, as well as being used in epidemiological studies such as virus exposure and determination of infection rate in the population. In this study, it was aimed to determine the disappearance time of total antibodies from the plasma by periodically monitoring the healthcare workers who have been documented as symptomatically or asymptomatically infected with COVID-19 and also to predict the risk of re-infection and the need for vaccination by measuring surrogate virus neutralization. After 30-45 days from the diagnosis of COVID-19 disease (in the acute period), in the 3rd, 6th and 9th months peripheral blood samples were taken from 123 healthcare professionals working in different areas of our hospital in terms of transmission risk and total antibody levels were measured against the SARS-CoV-2 N antigen and surrogate virus neutralization by serological methods. After the first reverse transcriptase polymerase chain reaction (RT-PCR) positivity, SARS-CoV-2-specific anti-nucleocapsid total antibody concentrations were reached to a peak value between 30-45 days (80.37 COI + 37.26) and persisted as positive in most of the participants (111/123, 90.2%) up to six months. Higher peak anti-nucleocapsid antibody titers were associated with longer detection of the antibody (r=0.745, p<0.02). The higher antibody titers were also found to be associated with increased age, more symptomatic disease, higher risk of recurrent virus exposure and lower RT-PCR Ct values and the time for these antibodies to disappear from the blood was also longer (p<0.02). Surrogate virus neutralization were over 70% in 97.8% (90/92) of the participants in the acute period of infection. The SARS-CoV-2 anti-nucleocapsid total antibody level is dynamic and disappears from the plasma within months, this period is shorter in young people, those with asymptomatic patients, those with lower antibody titer and low frequency of virus exposure and also the neutralization of the virus is much more lower. Monitoring of the antibody levels will guide about the immune response against SARS-CoV-2 and these results will give information about re-infection

    UVC-LED-based face mask design and efficacy against common germs

    No full text
    During the Covid-19 pandemic, one of the best means of personal protection was using face masks. In this context, the World Health Organization has declared the attempts to produce masks inactivating airborne virus species a welcome initiative. This preliminary study aimed to prove that airborne germs passing through a mask filter cartridge can be destroyed by the rays emitted from UVC LEDs placed in such cartridge. We therefore designed such a face mask and tested the efficiency of UVC LEDs placed in its cartridge against common contaminants, gram-positive Staphylococcus aureus, gram-negative Pseudomonas aeruginosa, and the influenza A/Puerto Rico/8/1934 virus because of its similarity with SARS CoV-2. Eight UVC LEDs with a total power of 75 mW provided sufficient germicidal effect for all three germs. In terms of safety, ozone production released during UVC LED emission was negligible. Our findings are promising, as they show that well-designed UVC-based face masks can be effective against airborne germs, but further research on a greater sample may help us learn more and optimise such face masks

    Real-life experience: sensitivity and specificity of nasal and saliva samples for COVID-19 diagnosis

    No full text
    Background COVID-19 (coronavirus disease 2019) outbreak has spread rapidly around the world, continues to show its effect, and it is not clear how long it will continue. For the diagnosis of COVID-19, it is important to ensure the comfort of the patients and to protect the healthcare workers (HCWs) by reducing the use of protective equipment. Aims To evaluate or assess whether the samples taken by the patient for COVID-19 testing during this pandemic period can be used in real-life experience. Methods Three different samples (nasopharyngeal taken by the healthcare worker, nasopharyngeal, and saliva taken by the patient) from 132 patients were evaluated for the diagnosis of COVID-19. The sensitivity and specificity of the samples in the diagnosis of COVID-19 were compared with real-life experience. Results Paired analyzes were performed by comparing each sample taken by the healthcare worker with the sample taken by the patient. The sensitivity of the three samples (nasopharyngeal taken by the healthcare worker, nasopharyngeal, and saliva taken by the patient) in the diagnosis of the COVID-19 was (100%, 98.7%, and 96.1%, respectively) accepted to be accurate. Conclusions The sample taken by the paramedic was compatible compared to the real-life experience for the samples taken by the patient in the COVID-19 pandemic period. During the pandemic that is unknown when it will end, this study demonstrated that taking the sample of the patient alone for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) test is a beneficial approach to the protection of the healthcare worker, reducing the need for protective equipment, increasing the patient's comfort and rapid sampling

    Detection of SARS-CoV-2 RNA in Upper Respiratory Swap Samples by Pooling Method

    No full text
    Background: Widespread and effective use of molecular diagnostic tests is indispensable for protecting public health and containing the severe respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. More than 1 year into the pandemic, as resources have reached a point of depiction, grouping samples in pools of certain sizes appears to be a reasonable method to reduce both the costs and the processing time without necessitating additional training, equipment, or materials

    Impact of Obesity on the Metabolic Control of Type 2 Diabetes: Results of the Turkish Nationwide Survey of Glycemic and Other Metabolic Parameters of Patients with Diabetes Mellitus (TEMD Obesity Study)

    No full text
    Background: Obesity is the main obstacle for metabolic control in patients with type 2 diabetes. Turkey has the highest prevalence of obesity and type 2 diabetes in Europe. The effect of obesity on the metabolic control, and the macro-and microvascular complications of patients are not apparent. Objectives: This nationwide survey aimed to investigate the prevalence of overweight and obesity among patients with type 2 diabetes and to search for the impact of obesity on the metabolic control of these patients. We also investigated the independent associates of obesity in patients with type 2 diabetes. Methods: We consecutively enrolled patients who were under follow-up for at least 1 year in 69 tertiary healthcare units in 37 cities. The demographic, anthropometric, and clinical data including medications were recorded. Patients were excluded if they were pregnant, younger than 18 years, had decompensated liver disease, psychiatric disorders interfering with cognition or compliance, had bariatric surgery, or were undergoing renal replacement therapy. Results: Only 10% of patients with type 2 diabetes (n = 4,648) had normal body mass indexes (BMI), while the others were affected by overweight (31%) or obesity (59%). Women had a significantly higher prevalence of obesity (53.4 vs. 40%) and severe obesity (16.6 vs. 3.3%). Significant associations were present between high BMI levels and lower education levels, intake of insulin, antihypertensives and statins, poor metabolic control, or the presence of microvascular complications. Age, gender, level of education, smoking, and physical inactivity were the independent associates of obesity in patients with type 2 diabetes. Conclusion: The TEMD Obesity Study shows that obesity is a major determinant of the poor metabolic control in patients with type 2 diabetes. These results underline the importance of prevention and management of obesity to improve health care in patients with type 2 diabetes. Also, the results point out the independent sociodemographic and clinical associates of obesity, which should be the prior targets to overcome, in the national fight with obesity. (c) 2019 The Author(s) Published by S. Karger AG, Base

    Turkish nationwide survEy of glycemic and other Metabolic parameters of patients with Diabetes mellitus (TEMD study)

    No full text
    Aims: Turkey has the highest prevalence of diabetes in Europe. It is therefore essential to know the overall cardiovascular risk and reveal the predictors of metabolic control in Turkish adults with diabetes mellitus

    Acute kidney disease beyond day 7 after major surgery: a secondary analysis of the EPIS-AKI trial

    No full text
    Purpose: Acute kidney disease (AKD) is a significant health care burden worldwide. However, little is known about this complication after major surgery. Methods: We conducted an international prospective, observational, multi-center study among patients undergoing major surgery. The primary study endpoint was the incidence of AKD (defined as new onset of estimated glomerular filtration rate (eCFR) &lt; 60&nbsp;ml/min/1.73&nbsp;m2 present on day 7 or later) among survivors. Secondary endpoints included the relationship between early postoperative acute kidney injury (AKI) (within 72&nbsp;h after major surgery) and subsequent AKD, the identification of risk factors for AKD, and the rate of chronic kidney disease (CKD) progression in patients with pre-existing CKD. Results: We studied 9510 patients without pre-existing CKD. Of these, 940 (9.9%) developed AKD after 7&nbsp;days of whom 34.1% experiencing an episode of early postoperative-AKI. Rates of AKD after 7&nbsp;days significantly increased with the severity (19.1% Kidney Disease Improving Global Outcomes [KDIGO] 1, 24.5% KDIGO2, 34.3% KDIGO3; P &lt; 0.001) and duration (15.5% transient vs 38.3% persistent AKI; P &lt; 0.001) of early postoperative-AKI. Independent risk factors for AKD included early postoperative-AKI, exposure to perioperative nephrotoxic agents, and postoperative pneumonia. Early postoperative-AKI carried an independent odds ratio for AKD of 2.64 (95% confidence interval [CI] 2.21-3.15). Of 663 patients with pre-existing CKD, 42 (6.3%) had worsening CKD at day 90. In patients with CKD and an episode of early AKI, CKD progression occurred in 11.6%. Conclusion: One in ten major surgery patients developed AKD beyond 7&nbsp;days after surgery, in most cases without an episode of early postoperative-AKI. However, early postoperative-AKI severity and duration were associated with an increased rate of AKD and early postoperative-AKI was strongly associated with AKD independent of all other potential risk factors
    corecore