5 research outputs found

    Long-term outcomes in patients who underwent surgical correction for atrioventricular septal defect

    Get PDF
    Objective: The follow-up results of patients operated for atrioventricular septal defect (AVSD) during 1996-2016 at Baskent University are presented. Methods: Data obtained from hospital records consists of preoperative echocardiographic and angiographic details, age and weight at surgery, operative details, Down syndrome presence, postoperative care details, early postoperative and latest echocardiographic findings and hospitalization for reintervention. Results: A total of 496 patient-files were reviewed including 314 patients (63.4%) with complete and 181 (36.6%) with partial AVSD (48.4% of all patients had Down syndrome). Atrioventricular (AV) valve morphology was Rastelli type A in 92.2%, B in 6.5%, and C in 1.3% of patients. The operative technique used was single-patch in 21.6% (108), double-patch in 25.8% (128), and modified single-patch (Wilcox) in 52.5% (260) of patients. The follow-up time was 37.79 +/- 46.70 (range, 0-198) months. A total of 64 patients (12.9%) had a rrhythmias while in the intensive care unit; pacemaker was implanted in 12 patients. A total of 78 patients (15.7%) were treated for pulmonary hypertensive crisis. The early morbidity and mortality in the postoperative first month were calculated as 38% and 10%, and the late morbidity and mortality (>1 month) were calculated as 13.1% and 1.9%, respectively. The rate of reoperation in our cohort was 8.9%. Conclusion: Although the early morbidity and mortality are low in AVSD operations, the rate of reoperations for left AV valve insufficiency are still high. Although Down syndrome is not a risk factor for early mortality, the co-morbid factors, such as longer postoperative mechanical ventilator or inotropic support, lead to higher risk for morbidity. The frequency of pulmonary hypertension and consequent complications are also high

    The Influence of On-pump Versus Off-pump Surgery on Short- and Medium-term Postoperative Coronary Flow Reserve After Coronary Artery Bypass Grafting

    No full text
    Background Although several clinical trials have compared surgical outcomes between off-pump and on-pump coronary artery bypass grafting (CABG), whether there is a difference in the early- and medium-term postoperative coronary microvascular functions is not fully understood. We compared short- and medium-term coronary microvascular function after off-pump and on-pump CABG
    corecore