20 research outputs found

    Meta-Analysis of Risk Stratification of SCN5A With Brugada Syndrome: Is SCN5A Always a Marker of Low Risk?

    Get PDF
    Background:SCN5A with Brugada syndrome (BrS) is not commonly considered as an independent risk marker for subsequent cardiac events. However, the risk of SCN5A combined with other clinical characteristics has not been fully investigated.Objectives: The aim of this study is to investigate and evaluate risk stratification and related risk factors of SCN5A in BrS.Methods: The databases of PubMed, EMBASE, Cochrane Library, MEDLINE, Chinese National Knowledge Infrastructure (CNKI) and Wanfang Data were searched for related studies published from January 2002 to May 2018 followed by meta-analysis. The BrS patients who underwent SCN5A gene tests were included. The prognosis and risk stratification of SCN5A combined with symptoms and asymptoms diagnosis in BrS, electrophysiology study (EPS) were then investigated and evaluated. Outcomes were defined as ventricular tachycardia/fibrillation (VT/VF), sudden cardiac death (SCD).Results: Eleven suitable studies involving 1892 BrS patients who underwent SCN5A gene tests were identified. SCN5A (+) was not considered to be a significant predictor of future cardiac events (95% CI: 0.89–2.11; P = 0.15; I2 = 0%). However, SCN5A (+) patients with symptoms at diagnosis revealed a higher prevalence of future VT/VF, SCD compared to SCN5A (–) patients with symptoms at diagnosis. (95% CI: 1.06–3.70; P = 0.03 I2 = 0%) Among asymptomatic patients, the risk did not significantly differ between SCN5A (+) patients and SCN5A (–) patients. (95% CI: 0.51–4.72; P = 0.45 I2 = 0 %). In an investigation involving patients in EPS (–) BrS electrocardiogram (ECG), the risk of SCN5A (+) is higher than that of SCN5A (–) (P < 0.001).Conclusions: In BrS patients with symptoms at diagnosis or EPS (–), the meta-analysis suggests that SCN5A (+) are at a higher risk of arrhythmic events than SCN5A (–)

    Heart Rate Recovery After Exercise Is Associated With Arrhythmic Events in Patients With Catecholaminergic Polymorphic Ventricular Tachycardia

    Get PDF
    BACKGROUND: Risk stratification in catecholaminergic polymorphic ventricular tachycardia remains ill defined. Heart rate recovery (HRR) immediately after exercise is regulated by autonomic reflexes, particularly vagal tone, and may be associated with symptoms and ventricular arrhythmias in patients with catecholaminergic polymorphic ventricular tachycardia. Our objective was to evaluate whether HRR after maximal exercise on the exercise stress test (EST) is associated with symptoms and ventricular arrhythmias. METHODS: In this retrospective observational study, we included patients ≤65 years of age with an EST without antiarrhythmic drugs who attained at least 80% of their age- and sex-predicted maximal HR. HRR in the recovery phase was calculated as the difference in heart rate (HR) at maximal exercise and at 1 minute in the recovery phase (ΔHRR1'). RESULTS: We included 187 patients (median age, 36 years; 68 [36%] symptomatic before diagnosis). Pre-EST HR and maximal HR were equal among symptomatic and asymptomatic patients. Patients who were symptomatic before diagnosis had a greater ΔHRR1' after maximal exercise (43 [interquartile range, 25-58] versus 25 [interquartile range, 19-34] beats/min; P<0.001). Corrected for age, sex, and relatedness, patients in the upper tertile for ΔHRR1' had an odds ratio of 3.4 (95% CI, 1.6-7.4) of being symptomatic before diagnosis (P<0.001). In addition, ΔHRR1' was higher in patients with complex ventricular arrhythmias at EST off antiarrhythmic drugs (33 [interquartile range, 22-48] versus 27 [interquartile range, 20-36] beats/min; P=0.01). After diagnosis, patients with a ΔHRR1' in the upper tertile of its distribution had significantly more arrhythmic events as compared with patients in the other tertiles (P=0.045). CONCLUSIONS: Catecholaminergic polymorphic ventricular tachycardia patients with a larger HRR following exercise are more likely to be symptomatic and have complex ventricular arrhythmias during the first EST off antiarrhythmic drug

    Interobserver variability in target definition for stereotactic arrhythmia radioablation

    Get PDF
    Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02–0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52–1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51–1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation

    Interobserver variability in target definition for stereotactic arrhythmia radioablation

    Get PDF
    BackgroundStereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR.MethodsDelineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient.ResultsTen electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02–0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52–1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51–1.55 cm, Dice-coefficient mean: 0.31 ± 0.21).ConclusionsInterobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation

    Electrophysiological study prior to planned pulmonary valve replacement in patients with repaired tetralogy of Fallot

    Get PDF
    International audienceAIM: Ventricular arrhythmias (VAs) are the most common cause of death in patients with repaired Tetralogy of Fallot (rTOF). However, risk stratifying remains challenging. We examined outcomes following programmed ventricular stimulation (PVS) with or without subsequent ablation in patients with rTOF planned for pulmonary valve replacement (PVR). METHODS: We included all consecutive patients with rTOF referred to our institution from 2010 to 2018 aged ≥18 years for PVR. Right ventricular (RV) voltage maps were acquired and PVS was performed from two different sites at baseline, and if non-inducible under isoproterenol. Catheter and/or surgical ablation was performed when patients were inducible or when slow conduction was present in anatomical isthmuses (AIs). Postablation PVS was undertaken to guide implantable cardioverter-defibrillator (ICD) implantation. RESULTS: Seventy-seven patients (36.2 ± 14.3 years old, 71% male) were included. Eighteen were inducible. In 28 patients (17 inducible, 11 non-inducible but with slow conduction) ablation was performed. Five had catheter ablation, surgical cryoablation in 9, both techniques in 14. ICDs were implanted in five patients. During a follow-up of 74 ± 40 months, no sudden cardiac death occurred. Three patients experienced sustained VAs, all were inducible during the initial EP study. Two of them had an ICD (low ejection fraction for one and important risk factor for arrhythmia for the second). No VAs were reported in the non-inducible group (p < .001). CONCLUSION: Preoperative EPS can help identifying patients with rTOF at risk for VAs, providing an opportunity for targeted ablation and may improve decision-making regarding ICD implantation

    Long-Term Arrhythmic and Nonarrhythmic Outcomes of Lamin A/C Mutation Carriers.

    No full text
    BACKGROUND Mutations in LMNA are variably expressed and may cause cardiomyopathy, atrioventricular block (AVB), or atrial arrhythmias (AAs) and ventricular arrhythmias (VA). Detailed natural history studies of LMNA-associated arrhythmic and nonarrhythmic outcomes are limited, and the prognostic significance of the index cardiac phenotype remains uncertain. OBJECTIVES This study sought to describe the arrhythmic and nonarrhythmic outcomes of LMNA mutation carriers and to assess the prognostic significance of the index cardiac phenotype. METHODS The incidence of AVB, AA, sustained VA, left ventricular systolic dysfunction (LVD) (= left ventricular ejection fraction ≤50%), and end-stage heart failure (HF) was retrospectively determined in 122 consecutive LMNA mutation carriers followed at 5 referral centers for a median of 7 years from first clinical contact. Predictors of VA and end-stage HF or death were determined. RESULTS The prevalence of clinical manifestations increased broadly from index evaluation to median follow-up: AVB, 46% to 57%; AA, 39% to 63%; VA, 16% to 34%; and LVD, 44% to 57%. Implantable cardioverter-defibrillators were placed in 59% of patients for new LVD or AVB. End-stage HF developed in 19% of patients, and 13% died. In patients without LVD at presentation, 24% developed new LVD, and 7% developed end-stage HF. Male sex (p = 0.01), nonmissense mutations (p = 0.03), and LVD at index evaluation (p = 0.004) were associated with development of VA, whereas LVD was associated with end-stage HF or death (p < 0.001). Mode of presentation (with isolated or combination of clinical features) did not predict sustained VA or end-stage HF or death. CONCLUSIONS LMNA-related heart disease was associated with a high incidence of phenotypic progression and adverse arrhythmic and nonarrhythmic events over long-term follow-up. The index cardiac phenotype did not predict adverse events. Genetic diagnosis and subsequent follow-up, including anticipatory planning for therapies to prevent sudden death and manage HF, is warranted

    Validation of novel 3-dimensional electrocardiographic mapping of atrial tachycardias by invasive mapping and ablation: a multicenter study

    Get PDF
    OBJECTIVES This study prospectively evaluated the role of a novel 3-dimensional, noninvasive, beat-by-beat mapping system, Electrocardiographic Mapping (ECM), in facilitating the diagnosis of atrial tachycardias (AT). BACKGROUND Conventional 12-lead electrocardiogram, a widely used noninvasive tool in clinical arrhythmia practice, has diagnostic limitations. METHODS Various AT (de novo and post-atrial fibrillation ablation) were mapped using ECM followed by standard-of-care electrophysiological mapping and ablation in 52 patients. The ECM consisted of recording body surface electrograms from a 252-electrode-vest placed on the torso combined with computed tomography-scan-based biatrial anatomy (CardioInsight Inc., Cleveland, Ohio). We evaluated the feasibility of this system in defining the mechanism of AT-macro-re-entrant (perimitral, cavotricuspid isthmus-dependent, and roof-dependent circuits) versus centrifugal (focal-source) activation-and the location of arrhythmia in centrifugal AT. The accuracy of the noninvasive diagnosis and detection of ablation targets was evaluated vis-Ă -vis subsequent invasive mapping and successful ablation. RESULTS Comparison between ECM and electrophysiological diagnosis could be accomplished in 48 patients (48 AT) but was not possible in 4 patients where the AT mechanism changed to another AT (n = 1), atrial fibrillation (n = 1), or sinus rhythm (n = 2) during the electrophysiological procedure. ECM correctly diagnosed AT mechanisms in 44 of 48 (92%) AT: macro-re-entry in 23 of 27; and focal-onset with centrifugal activation in 21 of 21. The region of interest for focal AT perfectly matched in 21 of 21 (100%) AT. The 2:1 ventricular conduction and low-amplitude P waves challenged the diagnosis of 4 of 27 macro-re-entrant (perimitral) AT that can be overcome by injecting atrioventricular node blockers and signal averaging, respectively. CONCLUSIONS This prospective multicenter series shows a high success rate of ECM in accurately diagnosing the mechanism of AT and the location of focal arrhythmia. Intraprocedural use of the system and its application to atrial fibrillation mapping is under way

    Characteristics of ventricular tachycardia ablation in patients with continuous flow left ventricular assist devices

    No full text
    Left ventricular assist devices (LVADs) are increasingly used as a bridge to cardiac transplantation or as destination therapy. Patients with LVADs are at high risk for ventricular arrhythmias. This study describes ventricular arrhythmia characteristics and ablation in patients implanted with a Heart Mate II device. All patients with a Heart Mate II device who underwent ventricular arrhythmia catheter ablation at 9 tertiary centers were included. Thirty-four patients (30 male, age 58±10 years) underwent 39 ablation procedures. The underlying cardiomyopathy pathogenesis was ischemic in 21 and nonischemic in 13 patients with a mean left ventricular ejection fraction of 17%±5% before LVAD implantation. One hundred and ten ventricular tachycardias (VTs; cycle lengths, 230-740 ms, arrhythmic storm n=28) and 2 ventricular fibrillation triggers were targeted (25 transseptal, 14 retrograde aortic approaches). Nine patients required VT ablation <1 month after LVAD implantation because of intractable VT. Only 10/110 (9%) of the targeted VTs were related to the Heart Mate II cannula. During follow-up, 7 patients were transplanted and 10 died. Of the remaining 17 patients, 13 were arrhythmia-free at 25±15 months. In 1 patient with VT recurrence, change of turbine speed from 9400 to 9000 rpm extinguished VT. Catheter ablation of VT among LVAD recipients is feasible and reasonably safe even soon after LVAD implantation. Intrinsic myocardial scar, rather than the apical cannula, seems to be the dominant substrate

    Datasheet1_Interobserver variability in target definition for stereotactic arrhythmia radioablation.pdf

    No full text
    BackgroundStereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR.MethodsDelineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient.ResultsTen electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02–0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52–1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51–1.55 cm, Dice-coefficient mean: 0.31 ± 0.21).ConclusionsInterobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.</p
    corecore