2,056 research outputs found
An Examination of Backgrounds to Early-Run Minimum-Bias Events in ATLAS at the LHC
The initial parts of the Large Hadron Collider (LHC) run will be a source of critical information - about the ATLAS detector and about the physics of collisions at TeV, including parton distribution evolution and the cross-sections of . The accelerator itself will be the source of some detector interest, as we have a first look at what have so far been speculations on the quality of the vacuum in the experimental insertion, and the cleanliness of the beam from the accelerator. The shakedown period, with its low beam squeeze, low luminosity, and undemanding trigger menus, will be of great interest, avoiding the pileup and radiation levels that will arrive with higher luminosity -- making it an important opportunity to investigate minimum-bias events in relative isolation. For the short lifetime of the Minimum Bias Trigger Scintillators (MBTS), which are expected to fail within a few months of running, they will aid in discriminating the minimum bias signal of inelastic non-single-diffractive collisions. Using single- or double-coincidence signatures, the MBTS system and other trigger and analysis strategies attempt to avoid triggering on otherwise empty bunch crossings and eliminate the effects of beam-gas collisions and beam-halo effects which would lead these spurious triggers that would reduce the general minimum-bias trigger efficiency. An examination of the effects of beam halo and beam -gas interactions on the minimum-bias trigger response is made. The signatures of the beam halo and beam gas are examined from the standard ATLAS tracking reconstruction
Design guide for high pressure oxygen systems
A repository for critical and important detailed design data and information, hitherto unpublished, along with significant data on oxygen reactivity phenomena with metallic and nonmetallic materials in moderate to very high pressure environments is documented. This data and information provide a ready and easy to use reference for the guidance of designers of propulsion, power, and life support systems for use in space flight. The document is also applicable to designs for industrial and civilian uses of high pressure oxygen systems. The information presented herein are derived from data and design practices involving oxygen usage at pressures ranging from about 20 psia to 8000 psia equal with thermal conditions ranging from room temperatures up to 500 F
The effects of continuous positive airway pressure therapy withdrawal on cardiac repolarization: data from a randomized controlled trialâ€
Aims The preliminary evidence supports an association between obstructive sleep apnoea (OSA), disturbed cardiac repolarization, and consequent cardiac dysrhythmias. The aim of the current trial was to assess the effects of continuous positive airway pressure (CPAP) therapy withdrawal on the measures of cardiac repolarization in patients with OSA. Methods and results Forty-one OSA patients established on CPAP treatment were randomized to either CPAP withdrawal (subtherapeutic CPAP) or continue therapeutic CPAP for 2 weeks. Polysomnography was performed, and indices of cardiac repolarization (QTc, TpTec intervals) and dispersion of repolarization (TpTe/QT ratio) were derived from 12-lead electrocardiography (ECG) at baseline and 2 weeks. Continuous positive airway pressure withdrawal led to a recurrence of OSA. Compared with therapeutic CPAP, subtherapeutic CPAP for 2 weeks was associated with a significant increase in the length of the QTc and TpTec intervals (mean difference between groups 21.4 ms, 95% CI 11.3-1.6 ms, P < 0.001 and 14.4 ms, 95% CI 7.2-21.5 ms, P < 0.001, respectively) and in the TpTe/QT ratio (mean difference between groups 0.02, 95% CI 0.00-0.03, P = 0.020). There was a statistically significant correlation between the change in apnoea/hypopnoea index (AHI) from baseline, and both the change in the QTc interval and the TpTec interval (r = 0.60, 95% CI 0.36-0.77, P < 0.001 and r = 0.45, 95% CI 0.17-0.67, P = 0.003, n = 41, respectively). Conclusion Continuous positive airway pressure withdrawal is associated with the prolongation of the QTc and TpTec intervals and TpTe/QT ratio, which may provide a possible mechanistic link between OSA, cardiac dysrhythmias, and thus sudden cardiac deat
Physiological consequences of CPAP therapy withdrawal in patients with obstructive sleep apnoea-an opportunity for an efficient experimental model
Randomised controlled trials (RCTs) of continuous positive airway pressure (CPAP) in obstructive sleep apnoea (OSA) are time consuming, and their findings often inconclusive or limited due to suboptimal CPAP adherence in CPAP-naïve patients with OSA. Short-term CPAP withdrawal in patients with prior optimal CPAP adherence results in recurrence of OSA and its consequences. Thus, this experimental model serves as an efficient tool to investigate both the consequences of untreated OSA, and potential treatment alternatives to CPAP. The CPAP withdrawal protocol has been thoroughly validated, and applied in several RCTs focusing on cardiovascular and metabolic consequences of untreated OSA, as well as the assessment of treatment alternatives to CPAP
MB 700 Anthropology for Christian Mission
Textbook: Cultural Anthropology: An Applied Perspective, fifth edition by Gary Ferraro Readings: Anthropology and Christian Mission: A Reader, Darrell Whiteman (ed.)Customs and Cultures by Eugene Nidahttps://place.asburyseminary.edu/syllabi/2521/thumbnail.jp
Recommended from our members
Quantitative measurements using soft-x-ray streak cameras
A Soft X-Ray Streak Camera (SXRSC) is a fast timing instrument sensitive to x rays from 100 eV to 300 keV. The instrument has excellent time resolution (approx. 15 ps) and large dynamic range (approx. 10/sup 3/) which are well suited for measuring x-ray pulses produced by laser-fusion targets. The SXRSC uses a thin transmission photocathode to convert x-rays to a secondary electron signal which is accelerated, focused, and deflected onto a phosphor producing an image of the x-ray pulse time history. In the past, such instruments have been used only to make relative measurements of the time history. At LLNL we have calibrated the SXRSC in order to make absolute intensity measurements of the soft x-ray flux from laser fusion targets. Such measurements will assist in understanding the laser plasma processes and conditions needed to attain laser-produced fusion. Because of the nature of the instrument, we have calibrated it in the dynamic mode using a small laser-produced pulsed x-ray source
Recommended from our members
Los Alamos x-ray characterization facilities for plasma diagnostics
A summary is given of characteristics of x-ray sources used by Los Alamos National Laboratory to calibrate various x-ray diagnostic packages and components. Included are D.C. sourcs in electron impact and fluorescence modes, a pulsed laser source for soft x rays with 100 ps time resolution, Febetron pulsed electron impact sources, and both EUV and x-ray synchrotron beamlines
- …