96 research outputs found
Image guidance using 3D-ultrasound (3D-US) for daily positioning of lumpectomy cavity for boost irradiation
<p>Abstract</p> <p>Purpose</p> <p>The goal of this study was to evaluate the use of 3D ultrasound (3DUS) breast IGRT for electron and photon lumpectomy site boost treatments.</p> <p>Materials and methods</p> <p>20 patients with a prescribed photon or electron boost were enrolled in this study. 3DUS images were acquired both at time of simulation, to form a coregistered CT/3DUS dataset, and at the time of daily treatment delivery. Intrafractional motion between treatment and simulation 3DUS datasets were calculated to determine IGRT shifts. Photon shifts were evaluated isocentrically, while electron shifts were evaluated in the beam's-eye-view. Volume differences between simulation and first boost fraction were calculated. Further, to control for the effect of change in seroma/cavity volume due to time lapse between the 2 sets of images, interfraction IGRT shifts using the first boost fraction as reference for all subsequent treatment fractions were also calculated.</p> <p>Results</p> <p>For photon boosts, IGRT shifts were 1.1 ± 0.5 cm and 50% of fractions required a shift >1.0 cm. Volume change between simulation and boost was 49 ± 31%. Shifts when using the first boost fraction as reference were 0.8 ± 0.4 cm and 24% required a shift >1.0 cm. For electron boosts, shifts were 1.0 ± 0.5 cm and 52% fell outside the dosimetric penumbra. Interfraction analysis relative to the first fraction noted the shifts to be 0.8 ± 0.4 cm and 36% fell outside the penumbra.</p> <p>Conclusion</p> <p>The lumpectomy cavity can shift significantly during fractionated radiation therapy. 3DUS can be used to image the cavity and correct for interfractional motion. Further studies to better define the protocol for clinical application of IGRT in breast cancer is needed.</p
Neonatal Thyroid Function in Seveso 25 Years after Maternal Exposure to Dioxin
Andrea Baccarelli and colleagues show that maternal exposure to a dioxin following the industrial accident in Seveso, Italy in 1976 is associated with modified neonatal thyroid function even many years later
The Italian National Register of infants with congenital hypothyroidism: twenty years of surveillance and study of congenital hypothyroidism
All the Italian Centres in charge of screening, diagnosis, and follow-up of infants with congenital hypothyroidism participate in the Italian National Registry of affected infants, which performs the nationwide surveillance of the disease. It was established in 1987 as a program of the Health Ministry and is coordinated by the Istituto Superiore di Sanità. The early diagnosis performed by the nationwide newborn screening programme, the prompt treatment and the appropriate clinical management of the patients carried out by the Follow-up Centres, and the surveillance of the disease performed by the National Register of infants with congenital hypothyroidism are the components of an integrated approach to the disease which has been successfully established in our country
Workshop. Ipotiroidismo congenito in Italia. Istituto Superiore di Sanita'. Roma, 18 luglio 2003. Riassunti
Consiglio Nazionale delle Ricerche - Biblioteca Centrale - P.le Aldo Moro, 7 , Rome / CNR - Consiglio Nazionale delle RichercheSIGLEITItal
Workshop. L'ipotiroidismo congenito in Italia. Istituto Superiore di Sanit. Roma, 18 luglio 2003. Riassunti
Consiglio Nazionale delle Ricerche - Biblioteca Centrale - P.le Aldo Moro, 7, Rome / CNR - Consiglio Nazionale delle RichercheSIGLEITItal
Workshop. L'ipotiroidismo congenito in Italia. Istituto Superiore di Sanita'. Roma, 16 Luglio 2004. Riassunti
Consiglio Nazionale delle Ricerche - Biblioteca Centrale - P.le Aldo Moro, 7 , Rome / CNR - Consiglio Nazionale delle RichercheSIGLEITItal
- …