5,919 research outputs found

    Investigation of stratiform sulphide mineralisation at McPhun's Cairn, Argyllshire

    Get PDF

    Lead, zinc and copper mineralisation in basal Carboniferous sediments at Westwater, south Scotland

    Get PDF
    A zioneo f lead, zinc and copperm ineralisatioins developedo ver a minimum I of 4 km of strikeo f basal Carboniferoucse mentstoneg roup sedimentsa nd immediatelyu nderlyingB irrenswarkL avas atwestwater,n ear Laqholm in south Scotland. Grades so far obtained from sparse rock exposures and from shallow boreholes a fissure sulphides are usuallyO .l-O.j%o f combinedm etals over 1-2 m of thickness,bu t vein of higher grade and a relativelyt hick zone of disseminated were also located. Galena, sphalerite,c halcopyritea ndbaryte occur mainly in thin dolomitev eins but disseminationosf galenaa re also presenti n sandstoneu nits. The mineralisatioins of low temperaturet ype I was emplaceda long northeasterlyt rendingn ormal faultsa nd cross faults regardeda s late Carboniferouisn age. and Mineralisatiohna s been controlledb y faulting,r egionalf aciesv aziation and local lithologicalv ariationa s well as by stratigraphipco sition. These controlsa re applicablei n furthere xplorationo f Lower Carboniferourso cks in both south and central Scotland. The heavy mineral fraction of stream sediment is the optimums amplingt ype in reconnaissanceex plorationo f areas of calcareous . rocks such as the Lower Carboniferouso f south Scotlanda nd basal till sampling is the most effectivem ethod of follow-upe xplorationi n those areas where glaciald epositsa re widespreada nd often thick

    Investigation of stratiform sulphide mineralisation at Meall Mor, South Knapdale, Argyll

    Get PDF
    A co-ordinated geochemical-geophysical-geological investigation of copper mineralisation in the Meal1 ?46r area, South Knapdale, Argyll was carried 0th in 1976 and followed by a drilling programme of 3 shallow holes in early 1977. The mineralisation occursin a zone of weak stratiform sulphide mineralisation (the pyrite zone) with a strike length of 1Okm in the Upper &ins Quartz&e of the Middle Dalradian. The geochemical drainage survey showed the existence of a strongly anomalous distribution of Cu and Sb in the Abhainn Srathain draining south from . Meal1 M&- and detailed soil sampling over the pyrite zone outlined a broad area enriched in copper. Deeper soil sampling confirmed the anomalously high copper values and a coincident IP anomaly was found stretching from Meal1 M& south to the old mine workings on Abhainn Srathain, and is probably caused by a local enrichment of pyrite and chalcopyrite within the pyrite zone. Three boreholes were drilled; two on coincident geochemical and geophysical anomalies, and the third beneath the old mines at Abhainn Srathain. Copper values in the first two holes range up to 0.24% Cu over 4.27m, but up to 1.06% Cu over 2.67m in the third and this enrichment may be related to a later remobilisation of the disseminated chalcopyrite. The results of subsequent drilling at two other sites are given in Appendix III

    Putative Voltage Sensitive Enzymes in Prokaryotes

    Get PDF

    Intensified array camera imaging of solid surface combustion aboard the NASA Learjet

    Get PDF
    An intensified array camera was used to image weakly luminous flames spreading over thermally thin paper samples in a low gravity environment aboard the NASA-Lewis Learjet. The aircraft offers 10 to 20 sec of reduced gravity during execution of a Keplerian trajectory and allows the use of instrumentation that is delicate or requires higher electrical power than is available in drop towers. The intensified array camera is a charge intensified device type that responds to light between 400 and 900 nm and has a minimum sensitivity of 10(exp 6) footcandles. The paper sample, either ashless filter paper or a lab wiper, burns inside a sealed chamber which is filled with 21, 18, or 15 pct. oxygen in nitrogen at one atmosphere. The camera views the edge of the paper and its output is recorded on videotape. Flame positions are measured every 0.1 sec to calculate flame spread rates. Comparisons with drop tower data indicate that the flame shapes and spread rates are affected by the residual g level in the aircraft

    How to Undertake a Clinically Relevant Systematic Review in a Rapidly Evolving Field: Magnetic Resonance Angiography

    Get PDF
    Objectives: The aim was to determine which generations of the evolving technology of magnetic resonance angiography (MRA) are currently of clinical relevance in two clinical applications. Our purpose was to plan a systematic review that would be valuable both to purchasers driven by cost-effectiveness and to practicing clinicians. Methods: Information was gathered from a search of major bibliographic databases, from a short questionnaire sent to 500 U.K. vascular radiologists and vascular surgeons, and from local clinical The authors thank A. Jackson and all those who completed a questionnaire. This work was carried out with the financial support of the Secretary of State for Health under the NHS Health Technology Assessment Programme, project 97/13/04. The views and opinions expressed do not necessarily reflect those of the Secretary of State for Health. In part, this work was undertaken by the Leeds Teaching Hospitals NHS Trust, which received funding from the NHS Executive. The views expressed in this publication are those of the authors and not necessarily those of the NHS Executive.experts. We asked which of the MRA techniques were currently used and, assuming availability, what would be their technique of choice. Results: There were 206 published articles that satisfied preliminary inclusion criteria: 69 discussed 2D time of flight (TOF); 47, 3D TOF; and 38, contrast-enhanced techniques. There were 162 questionnaires returned (60 radiologists, 102 surgeons). Of the total respondents, 77/162 (48%) used MRA in the assessment of carotid artery stenosis; 47/77 (61%) used 2D TOF; 32/77 (42%), 3D TOF; and 26/77 (34%), contrast-enhanced techniques. Thirty-five of 162 (22%) respondents used MRA in the assessment of peripheral vascular disease (PVD); 15/35 (43%) used 2D TOF, 4/35 (11%) used 3D TOF, and 22/35 (63%) used contrast-enhanced techniques. For those wishing to use MRA, contrast-enhanced techniques were the method of choice. Conclusions: The TOF methods that represent earlier generations of the technology remain clinically relevant, and will therefore be included in our systematic review. To ensure complete and relevant coverage in reviews of other evolving technologies, it would be advisable to obtain data for guidance in a similar way

    Use of magnetic resonance angiography to select candidates with recently symptomatic carotid stenosis for surgery: systematic review

    Get PDF
    Objective To determine if sufficient evidence exists to support the use of magnetic resonance angiography as a means of selecting patients with recently symptomatic high grade carotid stenosis for surgery. Design Systematic review of published research on the diagnostic performance of magnetic resonance angiography, 1990-9. Main outcome measures Performance characteristics of diagnostic test. Results 126 potentially relevant articles were identified, but many articles failed to examine die performance of magnetic resonance angiography as a diagnostic test at the surgical decision thresholds used in major clinical trials on endarterectomy. 26 articles were included in a meta-analysis that showed a maximal joint sensitivity and specificity of 99% (95% confidence interval 98% to 100%) for identifying 70-99% stenosis and 90% (81% to 99%) for identifying 50-99% stenosis. Only four articles evaluated contrast enhanced magnetic resonance angiography. Conclusions Magnetic resonance angiography is accurate for selecting patients for carotid endarterectomy at the surgical decision thresholds established in the major endarterectomy trials, but the evidence is not very robust because of the heterogeneity of the studies included. Research is to determine the diagnostic performance of the most recent developments in magnetic resonance angiography, including contrast enhanced techniques, as well as to assess the impact of magnetic resonance angiography on surgical decision making and outcomes

    X-boson cumulant approach to the periodic Anderson model

    Full text link
    The Periodic Anderson Model (PAM) can be studied in the infinite U limit by employing the Hubbard X operators to project out the unwanted states. We have already studied this problem employing the cumulant expansion with the hybridization as perturbation, but the probability conservation of the local states (completeness) is not usually satisfied when partial expansions like the Chain Approximation (CHA) are employed. Here we treat the problem by a technique inspired in the mean field approximation of Coleman's slave-bosons method, and we obtain a description that avoids the unwanted phase transition that appears in the mean-field slave-boson method both when the chemical potential is greater than the localized level Ef at low temperatures (T) and for all parameters at intermediate T.Comment: Submited to Physical Review B 14 pages, 17 eps figures inserted in the tex

    An Evaluation of Techniques for Sampling Skin Flora

    Get PDF
    Three methods of sampling skin bacteria were evaluated to determine whether the large differences observed from adjacent areas of the back were real or due to variability in sampling methods. It was found that in addition to actual differences in the skin flora populations of adjacent areas, there were significant differences in populations obtained by different sampling techniques and significant differences between individuals. Equally high bacterial populations were recovered from skin by the Teflon spatula method and the rayon swab method; however, scrubbing with rayon swabs gave the most consistent results
    corecore