54 research outputs found

    Serial interferon-gamma release assays during treatment of active tuberculosis in young adults

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The role of interferon-γ release assay (IGRA) in monitoring responses to anti-tuberculosis (TB) treatment is not clear. We evaluated the results of the QuantiFERON-TB Gold In-tube (QFT-GIT) assay over time during the anti-TB treatment of adults with no underlying disease.</p> <p>Methods</p> <p>We enrolled soldiers who were newly diagnosed with active TB and admitted to the central referral military hospital in South Korea between May 1, 2008 and September 30, 2009. For each participant, we preformed QFT-GIT assay before treatment (baseline) and at 1, 3, and 6 months after initiating anti-TB medication.</p> <p>Results</p> <p>Of 67 eligible patients, 59 (88.1%) completed the study protocol. All participants were males who were human immunodeficiency virus (HIV)-negative and had no chronic diseases. Their median age was 21 years (range, 20-48). Initially, 57 (96.6%) patients had positive QFT-GIT results, and 53 (89.8%), 42 (71.2%), and 39 (66.1%) had positive QFT-GIT results at 1, 3, and 6 months, respectively. The IFN-γ level at baseline was 5.31 ± 5.34 IU/ml, and the levels at 1, 3, and 6 months were 3.95 ± 4.30, 1.82 ± 2.14, and 1.50 ± 2.12 IU/ml, respectively. All patients had clinical and radiologic improvements after treatment and were cured. A lower IFN-γ level, C-reactive protein ≥ 3 mg/dl, and the presence of fever (≥ 38.3°C) at diagnosis were associated with negative reversion of the QFT-GIT assay.</p> <p>Conclusion</p> <p>Although the IFN-γ level measured by QFT-GIT assay decreased after successful anti-TB treatment in most participants, less than half of them exhibited QFT-GIT reversion. Thus, the reversion to negativity of the QFT-GIT assay may not be a good surrogate for treatment response in otherwise healthy young patients with TB.</p

    Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation.</p> <p>Hypothesis</p> <p>There is no difference, biomechanically, amongst the various reconstruction and augmentative methods.</p> <p>Study Design</p> <p>Controlled laboratory cadaveric study.</p> <p>Methods</p> <p>54 cadaveric native (acromioclavicular and coracoclavicular) ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1) in the intact states, 2) after modified Weaver-Dunn reconstruction (WD), 3) after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ), 4) after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP) or 5) after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS) and 6) after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt). Posterior-anterior (horizontal) loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005).</p> <p>Results</p> <p>Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p < 0.005).</p> <p>WD.ACJ provided additional posterior-anterior (P = 0. 039) but not superior (p = 0.250) stability when compared to WD alone.</p> <p>WD+PLmt, in loads and stiffness at failure superiorly, was similar to WD+CP (p = 0.066). WD+PLmt, in loads and stiffness at failure postero-anteriorly, was similar to WD+ACJ (p = 0.084).</p> <p>Superiorly, WD+CP had similar strength as WD+BS (p = 0.057), but it was less stiff (p < 0.005).</p> <p>Conclusions and Clinical Relevance</p> <p>Modified Weaver-Dunn procedure must always be supplemented with acromioclavicular capsuloligamentous repair to increase posterior-anterior stability. Palmaris-Longus tendon graft provides both additional superior and posterior-anterior stability when used for acromioclavicular capsuloligamentous reconstruction. It is a good alternative to clavicle hook plate in acromioclavicular dislocation.</p

    An Aggregate MapReduce Data Block Placement Strategy for Wireless IoT Edge Nodes in Smart Grid

    Get PDF
    Big data analytics has simplified processing complexity of large dataset in a distributed environment. Many state-of-the-art platforms i.e. smart grid has adopted the processing structure of big data and manages a large volume of data through MapReduce paradigm at distribution ends. Thus, whenever a wireless IoT edge node bundles a sensor dataset into storage media, MapReduce agent performs analytics and generates output into the grid repository. This practice has efficiently reduced the consumption of resources in such a giant network and strengthens other components of the smart grid to perform data analytics through aggregate programming. However, it consumes an operational latency of accessing large dataset from a central repository. As we know that, smart grid processes I/O operations of multi-homing networks, therefore, it accesses large datasets for processing MapReduce jobs at wireless IoT edge nodes. As a result, aggregate MapReduce at wireless IoT edge node produces a network congestion and operational latency problem. To overcome this issue, we propose Wireless IoT Edge-enabled Block Replica Strategy (WIEBRS), that stores in-place, partition-based and multi-homing block replica to respective edge nodes. This reduces the delay latency of accessing datasets for aggregate MapReduce and increases the performance of the job in the smart grid. The simulation results show that WIEBRS effective decreases operational latency with an increment of aggregate MapReduce job performance in the smart grid

    A Modified Method for Reconstruction of Chronic Rupture of the Quadriceps Tendon after Total Knee Replacement

    No full text
    We describe herein a modified technique for reconstruction of chronic rupture of the quadriceps tendon in a patient with bilateral total knee replacement and distal realignment of the patella. The surgery involved the application of a Dacron graft and the ‘double eights’ technique. The patient achieved satisfactory results after surgery and we believe that this technique of reconstruction offers advantages over other methods
    corecore