694 research outputs found

    Knowledge, attitude and perceptions about tetanus and rabies among family physicians; results of a survey at a teaching hospital in karachi, pakistan

    Get PDF
    To assess the knowledge, attitude and perception among family physicians about tetanus and rabies. Setting: This study was conducted at the International Family Physicians Conference held at the Aga Khan University. Method: It was a cross sectional study of convenient sampling. The participants were asked to fill a pre-tested questionnaire comprising of 26 questions. Both open and close ended questions were included. A total of 111 doctors fulfilling the inclusion criteria filled in the questionnaire.Result: Out of 111 doctors who participated in this study, vast majority were working in the urban area (86.5%). 59.5% had not seen a case of tetanus and 71% had not seen a case of rabies in the preceding 6 months. Only 37% would use both tetanus toxoid and tetanus immunoglobulin in case of a dirty wound; 30% would administer tetanus toxoid and anti-tetanus serum in such a case. About 65% knew the current recommendation on rabies vaccination whereas 58% knew the correct post-exposure prophylaxis in case of suspected rabies.Conclusion: The level of knowledge about tetanus and rabies was clearly found to be deficient. More than half of the doctors enrolled in the study did not show correct knowledge on tetanus and rabies vaccination. The reasons for these deficiencies in knowledge appear to be inadequate teaching about these important diseases in the medical school. In addition, lack of reading habit and non-availability of continuous medical education programmes at the government level also contributes

    Outcome of home mechanical ventilation

    Get PDF
    OBJECTIVE: To determine the outcome of patients discharged home on portable ventilator. DESIGN: Descriptive study. PLACE AND DURATION OF STUDY: The Aga Khan University Hospital, Karachi from January 2000 to December 2004. PATIENTS AND METHODS: All ventilator-dependent patients discharged home were contacted. Survivors were administered the EQ-5D Quality-of-Life instrument. SPSS version 13 was used to analyze data. RESULTS: Eleven patients were discharged home on invasive ventilation. Mean age was 49 years (range 10-98 years). Cause of ventilatory failure were cervical spine trauma in 36%, primary neurological disease in 27%, critical illness neuropathy and respiratory failure in 18% each. Survival rate was 73%, with three deaths. Mean duration of ventilation was 9.45 months (95% CI 3.24, 15.67). Rate of successful weaning after discharge was 36%, with 4 patients off all forms of ventilatory support and 2 on only nocturnal support. A 2.8 (95% CI 0.5, 16.6) relative risk towards successful weaning was associated with the presence of a family member as the primary care giver. Mean scores on the EQ-5D descriptive tool were; mobility 2 (-/+0.82), self-care 2 (-/+0.82), usual activities 1.86 (-/+0.69), pain/discomfort 1.43(-/+0.79), anxiety/depression 1.29 (-/+0.76). Mean score on the EQ-VAS was 48.2(-/+ 27.3). CONCLUSION: In carefully selected patients, home ventilation is a viable option with the expectation of successful weaning and survival. Patients discharged home on ventilation reported a reasonably good quality of life with proportionately more problems related to independence compared to overall well-being

    Improvements in Skeletal Muscle Can Be Detected Using Broadband NIRS in First-Time Marathon Runners

    Get PDF
    Skeletal muscle metabolic function is known to respond positively to endurance exercise interventions, such as marathon training. Studies investigating skeletal muscle have typically used muscle biopsy samples or magnetic resonance spectroscopy (MRS) to interrogate metabolic function. We aimed to non-invasively detect exercise-training-induced improvements in muscle function using broadband near-infrared spectroscopy (NIRS). We used NIRS to determine concentration changes in oxygenated haemoglobin (HbO2) and the oxidation state of cytochrome-c-oxidase (oxCCO) in gastrocnemius during arterial occlusion in 14 volunteers. We also used a cardio-pulmonary exercise test (CPET) to assess peak total body oxygen uptake (peakVO2; a measure of fitness). Measurements were made at baseline (BL) which was prior to a period of at least 16 weeks of training for the 2017 London Marathon, and then within 3 weeks after completion of the marathon, follow-up (FU). We observed an increase in locally measured muscle oxygen consumption and rate of oxCCO concentration change, but not in cardio-respiratory fitness measured as whole-body peak oxygen consumption (peakVO2)

    High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis

    Get PDF
    The X-Stop interspinous distraction device has shown to be an attractive alternative to conventional surgical procedures in the treatment of symptomatic degenerative lumbar spinal stenosis. However, the effectiveness of the X-Stop in symptomatic degenerative lumbar spinal stenosis caused by degenerative spondylolisthesis is not known. A cohort of 12 consecutive patients with symptomatic lumbar spinal stenosis caused by degenerative spondylolisthesis were treated with the X-Stop interspinous distraction device. All patients had low back pain, neurogenic claudication and radiculopathy. Pre-operative radiographs revealed an average slip of 19.6%. MRI of the lumbosacral spine showed a severe stenosis. In ten patients, the X-Stop was placed at the L4–5 level, whereas two patients were treated at both, L3–4 and L4–5 level. The mean follow-up was 30.3 months. In eight patients a complete relief of symptoms was observed post-operatively, whereas the remaining 4 patients experienced no relief of symptoms. Recurrence of pain, neurogenic claudication, and worsening of neurological symptoms was observed in three patients within 24 months. Post-operative radiographs and MRI did not show any changes in the percentage of slip or spinal dimensions. Finally, secondary surgical treatment by decompression with posterolateral fusion was performed in seven patients (58%) within 24 months. In conclusion, the X-Stop interspinous distraction device showed an extremely high failure rate, defined as surgical re-intervention, after short term follow-up in patients with spinal stenosis caused by degenerative spondylolisthesis. We do not recommend the X-Stop for the treatment of spinal stenosis complicating degenerative spondylolisthesis

    Reduction of Orc6 Expression Sensitizes Human Colon Cancer Cells to 5-Fluorouracil and Cisplatin

    Get PDF
    Previous studies from our group have shown that the expression levels of Orc6 were highly elevated in colorectal cancer patient specimens and the induction of Orc6 was associated with 5-fluorouracil (5-FU) treatment. The goal of this study was to investigate the molecular and cellular impact of Orc6 in colon cancer. In this study, we use HCT116 (wt-p53) and HCT116 (null-p53) colon cancer cell lines as a model system to investigate the impact of Orc6 on cell proliferation, chemosensitivity and pathways involved with Orc6. We demonstrated that the down regulation of Orc6 sensitizes colon cancer cells to both 5-FU and cisplatin (cis-pt) treatment. Decreased Orc6 expression in HCT-116 (wt-p53) cells by RNA interference triggered cell cycle arrest at G1 phase. Prolonged inhibition of Orc6 expression resulted in multinucleated cells in HCT-116 (wt-p53) cell line. Western immunoblot analysis showed that down regulation of Orc6 induced p21 expression in HCT-116 (wt-p53) cells. The induction of p21 was mediated by increased level of phosphorylated p53 at ser-15. By contrast, there is no elevated expression of p21 in HCT-116 (null-p53) cells. Orc6 down regulation also increased the expression of DNA damaging repair protein GADD45β and reduced the expression level of JNK1. Orc6 may be a potential novel target for future anti cancer therapeutic development in colon cancer

    Serotonin regulates prostate growth through androgen receptor modulation

    Get PDF
    Serotonin regulates prostate growth through androgen receptor modulationAging and testosterone almost inexorably cause benign prostatic hyperplasia (BPH) in Human males. However, etiology of BPH is largely unknown. Serotonin (5-HT) is produced by neuroendocrine prostatic cells and presents in high concentration in normal prostatic transition zone, but its function in prostate physiology is unknown. Previous evidence demonstrated that neuroendocrine cells and 5-HT are decreased in BPH compared to normal prostate. Here, we show that 5-HT is a strong negative regulator of prostate growth. In vitro, 5-HT inhibits rat prostate branching through down-regulation of androgen receptor (AR). This 5-HT's inhibitory mechanism is also present in human cells of normal prostate and BPH, namely in cell lines expressing AR when treated with testosterone. In both models, 5-HT's inhibitory mechanism was replicated by specific agonists of 5-Htr1a and 5-Htr1b. Since peripheral 5-HT production is specifically regulated by tryptophan hydroxylase 1(Tph1), we showed that Tph1 knockout mice present higher prostate mass and up-regulation of AR when compared to wild-type, whereas 5-HT treatment restored the prostate weight and AR levels. As 5-HT is decreased in BPH, we present here evidence that links 5-HT depletion to BPH etiology through modulation of AR. Serotoninergic prostate pathway should be explored as a new therapeutic target for BPH.Projects NORTE-01-0246-FEDER-000012, NORTE-01-0145-FEDER-000013 and NORTE-01-0145-FEDER-000023, supported by the Northern Portugal Regional Operational Program (NORTE 2020), under the Portugal 2020 Partnership Agreement, through the European Regional Development Fund (FEDER) and Bolsa de Investigação GSK Inovação em Urologia 2012info:eu-repo/semantics/publishedVersio

    Planning a cluster randomized trial with unequal cluster sizes: practical issues involving continuous outcomes

    Get PDF
    BACKGROUND: Cluster randomization design is increasingly used for the evaluation of health-care, screeening or educational interventions. At the planning stage, sample size calculations usually consider an average cluster size without taking into account any potential imbalance in cluster size. However, there may exist high discrepancies in cluster sizes. METHODS: We performed simulations to study the impact of an imbalance in cluster size on power. We determined by simulations to which extent four methods proposed to adapt the sample size calculations to a pre-specified imbalance in cluster size could lead to adequately powered trials. RESULTS: We showed that an imbalance in cluster size can be of high influence on the power in the case of severe imbalance, particularly if the number of clusters is low and/or the intraclass correlation coefficient is high. In the case of a severe imbalance, our simulations confirmed that the minimum variance weights correction of the variation inflaction factor (VIF) used in the sample size calculations has the best properties. CONCLUSION: Publication of cluster sizes is important to assess the real power of the trial which was conducted and to help designing future trials. We derived an adaptation of the VIF from the minimum variance weights correction to be used in case the imbalance can be a priori formulated such as "a proportion (γ) of clusters actually recruit a proportion (τ) of subjects to be included (γ ≤ τ)"

    IL-13 expression by blood T cells and not eosinophils is increased in asthma compared to non-asthmatic eosinophilic bronchitis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In asthma interleukin (IL)-13 is increased in the airway compared with non-asthmatic eosinophilic bronchitis. Whether this differential expression is specific to the airway or is more generalised is uncertain.</p> <p>Methods</p> <p>We sought to examine IL-13 expression in peripheral blood T-cells and eosinophils in asthma and non-asthmatic eosinophilic bronchitis. Peripheral blood CD3+ cell and eosinophil intracellular IL-13 expression from subjects with asthma, non-asthmatic eosinophilic bronchitis and healthy controls was assessed. The effect of priming by asthmatic serum on the release of IL-13 by peripheral blood mononuclear cells from healthy subjects was examined and the serum from these subjects was analysed for a range of chemokines and cytokines.</p> <p>Results</p> <p>The median (IQR)% intracellular IL-13 expression by CD3+ cells was increased in asthma [5.3 (2.7–9.8)%; n = 12] compared to non-asthmatic eosinophilic bronchitis [1.1 (0.5–3)%; n = 7] and healthy controls [1.7 (0.2–3%); n = 9] (p = 0.02), but was not significantly different in eosinophils across the groups. IL-13 released from healthy peripheral blood mononuclear cells (n = 10) was increased by asthmatic serum [117 (47.8–198)pg/ml] compared to control [78.5 (42.6–128)pg/ml; p = 0.02), but was not affected by non-asthmatic serum.</p> <p>Conclusion</p> <p>Our findings support the view that IL-13 expression is increased in peripheral blood-derived T cells in asthma and that asthmatic serum up-regulates IL-13 release from healthy peripheral blood mononuclear cells.</p

    Revisiting the technical validation of tumour biomarker assays: how to open a Pandora's box

    Get PDF
    A tumour biomarker is a characteristic that is objectively measured and evaluated in tumour samples as an indicator of normal biological processes, pathogenic processes, or pharmacologic responses to a therapeutic intervention. The development of a biomarker contemplates distinct phases, including discovery by hypothesis-generating preclinical or exploratory studies, development and qualification of the assay for the identification of the biomarker in clinical samples, and validation of its clinical significance. Although guidelines for the development and validation of biomarkers are available, their implementation is challenging, owing to the diversity of biomarkers being developed. The term 'validation' undoubtedly has several meanings; however, in the context of biomarker research, a test may be considered valid if it is 'fit for purpose'. In the process of validation of a biomarker assay, a key point is the validation of the methodology. Here we discuss the challenges for the technical validation of immunohistochemical and gene expression assays to detect tumour biomarkers and provide suggestions of pragmatic solutions to address these challenges
    • …
    corecore