2,397 research outputs found

    The Data Processing Pipeline for the Herschel-HIFI Instrument

    Get PDF
    The HIFI data processing pipeline was developed to systematically process diagnostic, calibration and astronomical observations taken with the HIFI science instrumentas part of the Herschel mission. The HIFI pipeline processed data from all HIFI observing modes within the Herschel automated processing environment, as well as, within an interactive environment. A common software framework was developed to best support the use cases required by the instrument teams and by the general astronomers. The HIFI pipeline was built on top of that and was designed with a high degree of modularity. This modular design provided the necessary flexibility and extensibility to deal with the complexity of batch-processing eighteen different observing modes, to support the astronomers in the interactive analysis and to cope with adjustments necessary to improve the pipeline and the quality of the end-products. This approach to the software development and data processing effort was arrived at by coalescing the lessons learned from similar research based projects with the understanding that a degree of foresight was required given the overall length of the project. In this article, both the successes and challenges of the HIFI software development process are presented. To support future similar projects and retain experience gained lessons learned are extracted.Comment: 18 pages, 5 figure

    Measurement of the dynamic response of the CERN DC spark system and preliminary estimates of the breakdown turn-on time

    Full text link
    The new High Repetition Rate (HRR) CERN DC Spark System has been used to investigate the current and voltage time structure of a breakdown. Simulations indicate that vacuum breakdowns develop on ns timescales or even less. An experimental benchmark for this timescale is critical for comparison to simulations. The fast rise time of breakdown may provide some explanation of the particularly high gradients achieved by low group velocity, and narrow bandwidth, accelerating structures such as the T18 and T24. Voltage and current measurements made with the previous system indicated that the transient responses measured were dominated by the inherent capacitances and inductances of the DC spark system itself. The bandwidth limitations of the HRR system are far less severe allowing rise times of approximately 12ns to be measured

    The asteroseismological potential of the pulsating DB white dwarf stars CBS 114 and PG 1456+103

    Full text link
    We have acquired 65 h of single-site time-resolved CCD photometry of the pulsating DB white dwarf star CBS 114 and 62 h of two-site high-speed CCD photometry of another DBV, PG 1456+103. The pulsation spectrum of PG 1456+103 is complicated and variable on time scales of about one week and could only partly be deciphered with our measurements. The modes of CBS 114 are more stable in time and we were able to arrive at a frequency solution somewhat affected by aliasing, but still satisfactory, involving seven independent modes and two combination frequencies. These frequencies also explain the discovery data of the star, taken 13 years earlier. We find a mean period spacing of 37.1 +/- 0.7 s significant at the 98% level between the independent modes of CBS 114 and argue that they are due to nonradial g-mode pulsations of spherical degree l=1. We performed a global search for asteroseismological models of CBS 114 using a genetic algorithm, and we examined the susceptibility of the results to the uncertainties of the observational frequency determinations and mode identifications (we could not provide m values). The families of possible solutions are identified correctly even without knowledge of m. Our optimal model suggests Teff = 21,000 K and M_* = 0.730 M_sun as well as log(M_He/M_*) = -6.66, X_O = 0.61. This measurement of the central oxygen mass fraction implies a rate for the ^12C(alpha,gamma)^16O nuclear reaction near S_300=180 keV b, consistent with laboratory measurements.Comment: 10 pages, 10 embedded figures, 3 embedded tables. Accepted for publication in MNRA

    Spectroscopic characterization and detection of Ethyl Mercaptan in Orion

    Full text link
    New laboratory data of ethyl mercaptan, CH3_{3}CH2_{2}SH, in the millimeter and submillimeter-wave domains (up to 880 GHz) provided very precise values of the spectroscopic constants that allowed the detection of gauchegauche-CH3_3CH2_2SH towards Orion KL. 77 unblended or slightly blended lines plus no missing transitions in the range 80-280 GHz support this identification. A detection of methyl mercaptan, CH3_{3}SH, in the spectral survey of Orion KL is reported as well. Our column density results indicate that methyl mercaptan is \simeq 5 times more abundant than ethyl mercaptan in the hot core of Orion KL.Comment: Accepted for publication in ApJL (30 January 2014)/ submitted (8 January 2014

    Absolute differential positronium-formation cross sections

    Get PDF
    The first absolute experimental determinations of the differential cross-sections for the formation of ground-state positronium are presented for He, Ar, H2 and CO2 near 0○. Results are compared with available theories. The ratio of the differential and integrated cross-sections for the targets exposes the higher propensity for forward-emission of positronium formed from He and H2

    Calibrating AIS images using the surface as a reference

    Get PDF
    A method of evaluating the initial assumptions and uncertainties of the physical connection between Airborne Imaging Spectrometer (AIS) image data and laboratory/field spectrometer data was tested. The Tuscon AIS-2 image connects to lab reference spectra by an alignment to the image spectral endmembers through a system gain and offset for each band. Images were calibrated to reflectance so as to transform the image into a measure that is independent of the solar radiant flux. This transformation also makes the image spectra directly comparable to data from lab and field spectrometers. A method was tested for calibrating AIS images using the surface as a reference. The surface heterogeneity is defined by lab/field spectral measurements. It was found that the Tuscon AIS-2 image is consistent with each of the initial hypotheses: (1) that the AIS-2 instrument calibration is nearly linear; (2) the spectral variance is caused by sub-pixel mixtures of spectrally distinct materials and shade, and (3) that sub-pixel mixtures can be treated as linear mixtures of pure endmembers. It was also found that the image can be characterized by relatively few endmembers using the AIS-2 spectra

    Material Properties Measurements for Selected Materials

    Get PDF
    Hugoniot equation of state measurements were made on Coconino sandstone, Vacaville basalt, Kaibab limestone, Mono Crater, pumice and Zelux (a polycarbonate resin) for pressures to 2 Mb. A single data point was obtained for fused quartz at 1.6 Mb. In addition to the hugoniot studies, the uniaxial compressive stress behavior of Vacaville basalt and Zelux was investigated at strain rates from about 10(exp -5)/sec to 10(exp 3)/second. The data presented include the stress - strain relations as a function of strain rate for these two materials

    White Dwarfs: Cosmological and Galactic Probes

    Get PDF
    The emphasis on white dwarf stars and cosmology arises from the most recent advances in cosmological and galactic structure research in which white dwarf stars are playing a very prominent role. Examples are Type Ia supernovae (i.e. white dwarf supernovae), the origin and evolution of the universe, the age of the galactic disk, cosmochronology using white dwarfs in globular clusters and galactic clusters, and the physics of accretion onto compact (very dense) stars. As an assisting guide to the reader, we have included, by invitation, comprehensive review articles in each of the four major areas of the book, white dwarf supernovae, cosmology, accretion physics and galactic structure. The reviews include introductory material that they build upon. The book is suitable and most useful to advanced undergraduates, graduate students and scientific professionals (e.g. astronomers, astrophysicists, cosmologists, physicists)

    Barriers to providing palliative care for older people in acute hospitals

    Get PDF
    Background: the need for access to high-quality palliative care at the end of life is becoming of increasing public health concern. The majority of deaths in the UK occur in acute hospitals, and older people are particularly likely to die in this setting. However, little is known about the barriers to palliative care provision for older people within acute hospitals. Objective: to explore the perspectives of health professionals regarding barriers to optimal palliative care for older people in acute hospitals. Methods: fifty-eight health professionals participated in eight focus groups and four semi-structured interviews. Results: participants identified various barriers to palliative care provision for older people, including attitudinal differences to the care of older people, a focus on curative treatments within hospitals and a lack of resources. Participants also reported differing understandings of whose responsibility it was to provide palliative care for older people, and uncertainly over the roles of specialist and generalist palliative care providers in acute hospitals. Conclusions: numerous barriers exist to the provision of high-quality palliative care for older people within acute hospital settings. Additional research is now required to further explore age-related issues contributing to poor access to palliative care
    corecore