162 research outputs found

    Ultrasound shear wave elastography for liver disease. A critical appraisal of the many actors on the stage

    Get PDF
    In the last 12\u200a-\u200a18 months nearly all ultrasound manufacturers have arrived to implement ultrasound shear wave elastography modality in their equipment for the assessment of chronic liver disease; the few remaining players are expected to follow in 2016.When all manufacturers rush to a new technology at the same time, it is evident that the clinical demand for this information is of utmost value. Around 1990, there was similar demand for color Doppler ultrasound; high demand for contrast-enhanced ultrasonography was evident at the beginning of this century, and around 2010 demand increased for strain elastography. However, some issues regarding the new shear wave ultrasound technologies must be noted to avoid misuse of the resulting information for clinical decisions. As new articles are expected to appear in 2016 reporting the findings of the new technologies from various companies, we felt that the beginning of this year was the right time to present an appraisal of these issues. We likewise expect that in the meantime EFSUMB will release a new update of the existing guidelines 1 2.The first ultrasound elastography method became available 13 years ago in the form of transient elastography with Fibroscan(\uae) 3. It was the first technique providing non-invasive quantitive information about the stiffness of the liver and hence regarding the amount of fibrosis in chronic liver disease 3. The innovation was enormous, since a non-invasive modality was finally available to provide findings otherwise achievable only by liver biopsy. In fact, prior to ultrasound elastography, a combination of conventional and Doppler ultrasound parameters were utilized to inform the physician about the presence of cirrhosis and portal hypertension 4. However, skilled operators were required, reproducibility and diagnostic accuracy were suboptimal, and it was not possible to differentiate the pre-cirrhotic stages of fibrosis. All these limitations were substantially improved by transient elastography, performed with Fibroscan(\uae), a technology dedicated exclusively to liver elastography. Since then, more than 1300 articles dealing with transient elastography have been listed in PubMed, some describing results with more than 10,000 patients 5. The technique has been tested in nearly all liver disease etiologies, with histology as the reference standard. Meta-analysis of data, available in many etiologies 6, showed good performance and reproducibility as well as some situations limiting reliability 5. Thresholds for the different fibrosis stages (F0 to F4) have been provided by many large-scale studies utilizing histology as the reference standard 7. Transient elastography tracks the velocity of shear waves generated by the gentle hit of a piston on the skin, with the resulting compression wave traveling in the liver along its longitudinal axis. The measurement is made in a 4\u200acm long section of the liver, thus able to average slightly inhomogeneous fibrotic deposition.In 2008 a new modality became available, Acoustic Radiation Force Impulse (ARFI) quantification, and classified by EFSUMB 1 as point shear wave elastography (pSWE), since the speed of the shear wave (perpendicular to the longitudinal axis) is measured in a small region (a "point", few millimeters) at a freely-choosen depth within 8\u200acm from the skin. This technology was the first to be implemented in a conventional ultrasound scanner by Siemens(\uae) 8. Several articles have been published regarding this technology, most with the best reference standards 9, some including findings on more than 1000 hepatitis C patients 10 or reporting meta-analysis of data 11. Although the correlation between Siemens pSWE and transient elastography appeared high 12 13, the calculated thresholds for the different fibrosis stages and the stiffness ranges between the two techniques are not superimposable.Interestingly, pSWE appears to provide greater applicability than transient elastography for measuring both liver 13 and spleen stiffness, which is a new application of elastography 14, of interest for the prediction of the degree of portal hypertension 15 16.Nowadays other companies have started producing equipment with pSWE technology, but only very few articles have been published so far, for instance describing the use of Philips(\uae) equipment, which was the second to provide pSWE. These articles show preliminary good results also in comparison with TE 17 18. Not enough evidence is currently available in the literature about the elastographic performance of the products most recently introduced to the market. Furthermore, with some products the shear wave velocities generated by a single ultrasound acoustic push pulse can be measured in a bidimensional area (a box in the range of 2\u200a-\u200a3\u200acm per side) rather than in a single small point, producing a so-called bidimensional 2D-SWE 1. The stiffness is depicted in color within the area and refreshing of the measurement occurs every 1\u200a-\u200a2 seconds. Once the best image is acquired, the operator chooses a Region Of Interest (ROI) within the color box, where the mean stiffness is then calculated. 2D-SWE can be performed as a "one shot" technique or as a semi-"real-time" technique for a few seconds (at about 1 frame per second) in order to obtain a stable elastogram. With either technique, there should be no motion/breathing during image acquisition. A bidimensional averaged area should overcome the limitation of pSWE to inadvertently investigate small regions of greater or lesser stiffness than average. A shear wave quality indicator could be useful to provide real-time feedback and optimize placement of the sampling ROIs, a technology recently presented by Toshiba(\uae), but which is still awaiting validation in the literature.Supersonic Imagine by Aixplorer(\uae) which works with a different modality of insonation and video analysis compared to the the previously-mentioned three techniques (i.\u200ae., transient elastography, pSWE and 2D-SWE), leading to a bidimensional assessment of liver stiffness in real time up to 5\u200aHz and in larger regions; thus this technique is also termed real-time 2\u200aD SWE. It has been available on the market for a few years 19 20, and many articles have been published showing stiffness values quite similar to those of Fibroscan(\uae) 21; likewise, defined thresholds based on histological findings have appeared in several articles 19 20 21.After this brief summary of the technological state of the art we would like to mention the following critical issues that we believe every user should note prior to providing liver stiffness reports. \ub7 The thresholds obtained from the "oldest" techniques for the various fibrosis stages based on hundreds of patients with histology as reference standard cannot be straightforwardly applied to the new ultrasound elastography techniques, even if based on the same principle (e.\u200ag. pSWE). In fact, the different manufacturers apply proprietary patented calculation modes, which might result in slightly to moderately different values. It should be kept in mind that the range for intermediate fibrosis stages (F1 to F3) is quite narrow, in the order of 2\u200a-\u200a3 kilopascal (over a total range spanning 2 to 75 kPa with Fibroscan), so that slightly different differences in outputs could shift the assessment of patients from one stage to another. Comparative studies using phantoms and healthy volunteers, as well as patients, are eagerly awaited. In fact, the equipment might not produce linear correlations of measurements at different degrees of severity of fibrosis. As a theoretical example, some equipment might well correlate in their values with an older technique, such as transient elastography, at low levels of liver fibrosis, but not as well in cases of more advanced fibrosis or vice versa. Consequentely, when elastography data are included in a report, the equipment utilized for the measurement should be clearly specified, and conclusions about the fibrosis stage should be withheld if an insufficient number of comparative studies with solid reference standards are available for that specific equipment.. \ub7 Future studies using histology as a reference might be biased in comparison to previous studies, since nowadays fewer patients with chronic hepatitis C or hepatitis B undergo biopsy. In fact, due to wide availability of effective drugs as well as the use of established elastography methods for patients with viral hepatitis, most cases submitted to biopsy today have uncertain etiology or inconsistent and inconclusive clinical data. Therefore, extrapolated thresholds from such inhomogeneous populations applied to more ordinary patients with viral hepatitis might become problematic in the future, although no better solution is currently anticipated. This situation might lead to the adoption of a standard validated elastographic method as reference, but this has to be agreed-upon at an international level.. \ub7 Ultrasound elastography embedded in conventional scanners usually allows the choice of where to place the ROI within the color stiffness box and whether to confirm or exclude each single measurement when determining the final value. Thus, the operator has a greater potential to influence the final findings than with Fibroscan\uae, where these choices are not available. This has to be kept in mind to avoid the possibility that an operator could, even inadvertently, tend to confirm an assumption about that specific patient or to confirm the patient's expectations.. \ub7 Quality criteria for the new technologies following transient elastography are absent (depending on the manufacturer) or have not been satisfactorily defined, so that the information potentially inserted in a report cannot currently be judged for its reliability by the clinician.. (ABSTRACT TRUNCATED

    Some tests of 3D ultrasonic traveltime tomography on the Eleonora d'Aragona statue (F. Laurana, 1468)

    Get PDF
    The use of a non-destructive technique in situ can be a valuable diagnostic tool to support verification of restoration, as well as a monitoring technique in works of art or historical monuments. We present a high resolution 3D ultrasonic tomography to one of the most important statues of the Regional Gallery of Palazzo Abatellis of Palermo, the bust of Eleonora d'Aragona by F. Laurana (1430–1502). This technique allowed to study the structural continuity of the material of the marble. Some tests have been carried out to optimize inversion parameters, such as voxel size and to choose between straight and curved rays. We propose to calculate a minimum lateral resolution using the sampling frequency instead of that of the probes. Consequently it was chosen to use a voxel size of 2 cm, lower than the expected resolution, 0.07 m (calculated considering the median ray length), and also to use curved rays instead of straight rays approximation. The resulting model showed velocity values corresponding to a sufficiently homogeneous and well-preserved marble, but in the lower front portion of the trunk at the breasts, that bears the entire weight of the artwork, low velocity values are present

    Integrated three-dimensional models for noninvasive monitoring and valorization of the Morgantina silver treasure (Sicily)

    Get PDF
    The Morgantina silver treasure belonging to the Archaeological Museum of Aidone (Sicily) was involved in a three-dimensional (3-D) survey and diagnostics campaign for monitoring the collection over time in anticipation of their temporary transfer to the Metropolitan Museum of Art in New York for a period of 4 years. Using a multidisciplinary approach, a scientific and methodological protocol based on noninvasive techniques to achieve a complete and integrated knowledge of the precious items and their conservation state, as well as to increase their valorization, has been developed. All acquired data, i.e., 3-D models, ultraviolet fluorescence, x-ray images, and chemical information, will be made available, in an integrated way, within a web-oriented platform, which will present an in-progress tool to deepen existing archaeological knowledge and production technologies and to obtain referenced information of the conservation state before and after moving of the collection from its exposure site

    Extracapsular femoral neck fractures treated with total hip arthroplasty: identification of a population with better outcomes

    Get PDF
    BACKGROUND: Femoral neck fractures (FNF) are associated to patient’s disability, reduced quality of life and mortality. None of the fixation devices commonly used for extracapsular (EC) FNF (i.e., dynamic hip screws (DHS) and intramedullary nails (IN)) is clearly superior to the other, especially in case of unstable fractures (31.A2 and 31.A3 according to AO/OTA classification). The aim of our study was to identify a sub-population of patients with EC fractures in which better outcomes could be obtainable using total hip arthroplasty (THA). METHODS: All patients with EC unstable fractures treated with THA were included in the present study. Demographic data, American Society of Anesthesiologists (ASA) score, hospitalization length, transfusion rate, implant-related complications and mortality rate were collected. Clinical outcomes were evaluated using the Oxford Hip Score (OHS), while patients’ general health status through the 12 Item Short Form questionnaires (SF-12). RESULTS: 30 patients (7 male; 23 female) with a mean age of 78.8 years were included. The 1-year mortality rate was 13.3%. The mean OHS was 27.5, while the mean SF-12 were 45.84 for the mental item and 41.6 for the physical one. Age was the only factor associated with the OHS and patients older than 75 years presented a 12- fold higher risk of developing bad outcomes. CONCLUSIONS: THA seems to be a viable option for unstable EC fractures, with good clinical outcomes, especially in patients younger than 75 years of age. The mortality rate associated with THA in EC fractures is low and anyway comparable with IN

    MODERN TECHNOLOGIES FOR CONSERVATION OF VILLA ZITO PAINTINGS COLLECTION (PALERMO – SICILY)

    Get PDF
    In this study we describe the conservative integrated approach performed on 40 paintings, dating from different period (XVII- XX century), belonging to “Fondazione Sicilia “ and exposed in Villa Zito paint gallery in Palermo (Mazzocca 2015). Through a multidisciplinary approach both constitutive materials and state of conservation have been determined. Particularly, pigments and executive techniques were identified by non-invasive diagnostic investigation (XRF analysis, UV fluorescence acquisition, and IR Reflectography) as well as previous restorations events. The study has included the revealing of microbial colonization by using non-invasive sampling methods (Nylon membrane fragment) and molecular biology tools for the identification of microbial taxa (Palla et al 2010). For this reason another aim is the application of sustainable methods as alternative to traditional restoration procedures, which can sometimes be detrimental for artworks, humans and environment. In particular, in vitro culture (Nutrient, Sabouraud agar), optical microscopy observations (O.M.) and molecular biology investigations (genomic DNA extraction, PCR, sequencing and sequence analysis) reveal the presence of bacteria colonies belonging to Micrococcus sp., Staphylococcus sp. and Bacillus sp. In order to remove undesired layers appropriate cleaning protocols have been tested, using gelled solutions at specific pH values or dry cleaning methods (Cremonesi 2011; Daudin-Schotte et al 2013). Agar-Agar or Gellan-Gum hard gels have been utilized in order to remove dirty or proteinaceous layers by adding specific enzymatic solutions in the gels. The enzymatic cleaning has been performed at room temperature (20-23°C); the removal (total/partial) has been obtained after 10 minutes of application (Barresi et al 2015). Instead, on unvarnished and water sensitive paintings, the RCE-dry cleaning method (Rijksdienst voor het Cultureel Erfgoed- Netherland Institute for Cultural Heritage) have been applied following ad hoc protocols (Giordano et al 2014; Daudin-Schotte et al 2013)

    A djuvant treatment in patients at high risk of recurrence of thymoma: Efficacy and safety of a three-dimensional conformal radiation therapy regimen

    No full text
    The clinical benefits of postoperative radiation therapy (PORT) for patients with thymoma are still controversial. In the absence of defined guidelines, prognostic factors such as stage, status of surgical margins, and histology are often considered to guide the choice of adjuvant treatment (radiotherapy and/or chemotherapy). In this study, we describe our single-institution experience of three-dimensional conformal PORT administered as adjuvant treatment to patients with thymoma. METHODS: Twenty-two consecutive thymoma patients (eleven male and eleven female) with a median age of 52 years and treated at our institution by PORT were analyzed. The patients were considered at high risk of recurrence, having at least one of the following features: stage IIB or III, involved resection margins, or thymic carcinoma histology. Three-dimensional conformal PORT with a median total dose on clinical target volume of 50 (range 44-60) Gy was delivered to the tumor bed by 6-20 MV X-ray of the linear accelerator. Follow-up after radiotherapy was done by computed tomography scan every 6 months for 2 years and yearly thereafter. RESULTS: Two of the 22 patients developed local recurrence and four developed distant metastases. Median overall survival was 100 months, and the 3-year and 5-year survival rates were 83% and 74%, respectively. Median disease-free survival was 90 months, and the 5-year recurrence rate was 32%. On univariate analysis, pathologic stage III and presence of positive surgical margins had a significant impact on patient prognosis. Radiation toxicity was mild in most patients and no severe toxicity was registered. CONCLUSION: Adjuvant radiotherapy achieved good local control and showed an acceptable toxicity profile in patients with high-risk thymoma

    Effects of Some New Antioxidants on Apoptosis and ROS Production in AFB1 Treated Chickens

    Get PDF
    Aflatoxin B1 (AFB1), the mainly Aspergillus fungi derived mycotoxin, is well known for its carcinogenic effects on liver, and frequently occurs in food supplies, leading to fatal consequences in both farm animals and humans. Poultry, one of the most important segments of agro-industry, has been demonstrated to be extremely sensitive to AFB1 intake, which results in chickens' low performance, decreased quality of both eggs and meat and a negative economic feedback. Oxidative stress caused by AFB1 plays a crucial role in chickens' kidney damage by generating lipid peroxidation accompanied by a concomitant increase in the antioxidant enzymes involved in ROS metabolism (NADPH oxidase isoform 4 (NOX4) and its regulatory subunit p47-phox). The aim of the present work was to investigate the benefits of dietary supplementation, in chickens affected by AFB1 mycotoxicosis, using a new Feed additive (FA) containing a mixture of a tri-octahedral Na-smectite with a ligno-cellulose-based material an antioxidant adjuvant. Exposure of AFB1-treated chickens to the feed additive induced a significant down-regulation of both NOX4 and p47-phox genes expression levels. This trend was confirmed by their protein expression, demonstrating the great potential of the FA to counteract oxidative stress. To conclude, these results could open new perspectives in the methods of feeding chickens, using eco-friendly dietary supplements able to reduce AFB1-induced mycotoxicosis and to ameliorate poultry performances

    Beta-Blocker Use in Older Hospitalized Patients Affected by Heart Failure and Chronic Obstructive Pulmonary Disease: An Italian Survey From the REPOSI Register

    Get PDF
    Beta (β)-blockers (BB) are useful in reducing morbidity and mortality in patients with heart failure (HF) and concomitant chronic obstructive pulmonary disease (COPD). Nevertheless, the use of BBs could induce bronchoconstriction due to β2-blockade. For this reason, both the ESC and GOLD guidelines strongly suggest the use of selective β1-BB in patients with HF and COPD. However, low adherence to guidelines was observed in multiple clinical settings. The aim of the study was to investigate the BBs use in older patients affected by HF and COPD, recorded in the REPOSI register. Of 942 patients affected by HF, 47.1% were treated with BBs. The use of BBs was significantly lower in patients with HF and COPD than in patients affected by HF alone, both at admission and at discharge (admission, 36.9% vs. 51.3%; discharge, 38.0% vs. 51.7%). In addition, no further BB users were found at discharge. The probability to being treated with a BB was significantly lower in patients with HF also affected by COPD (adj. OR, 95% CI: 0.50, 0.37-0.67), while the diagnosis of COPD was not associated with the choice of selective β1-BB (adj. OR, 95% CI: 1.33, 0.76-2.34). Despite clear recommendations by clinical guidelines, a significant underuse of BBs was also observed after hospital discharge. In COPD affected patients, physicians unreasonably reject BBs use, rather than choosing a β1-BB. The expected improvement of the BB prescriptions after hospitalization was not observed. A multidisciplinary approach among hospital physicians, general practitioners, and pharmacologists should be carried out for better drug management and adherence to guideline recommendations

    Clinical features and outcomes of elderly hospitalised patients with chronic obstructive pulmonary disease, heart failure or both

    Get PDF
    Background and objective: Chronic obstructive pulmonary disease (COPD) and heart failure (HF) mutually increase the risk of being present in the same patient, especially if older. Whether or not this coexistence may be associated with a worse prognosis is debated. Therefore, employing data derived from the REPOSI register, we evaluated the clinical features and outcomes in a population of elderly patients admitted to internal medicine wards and having COPD, HF or COPD + HF. Methods: We measured socio-demographic and anthropometric characteristics, severity and prevalence of comorbidities, clinical and laboratory features during hospitalization, mood disorders, functional independence, drug prescriptions and discharge destination. The primary study outcome was the risk of death. Results: We considered 2,343 elderly hospitalized patients (median age 81 years), of whom 1,154 (49%) had COPD, 813 (35%) HF, and 376 (16%) COPD + HF. Patients with COPD + HF had different characteristics than those with COPD or HF, such as a higher prevalence of previous hospitalizations, comorbidities (especially chronic kidney disease), higher respiratory rate at admission and number of prescribed drugs. Patients with COPD + HF (hazard ratio HR 1.74, 95% confidence intervals CI 1.16-2.61) and patients with dementia (HR 1.75, 95% CI 1.06-2.90) had a higher risk of death at one year. The Kaplan-Meier curves showed a higher mortality risk in the group of patients with COPD + HF for all causes (p = 0.010), respiratory causes (p = 0.006), cardiovascular causes (p = 0.046) and respiratory plus cardiovascular causes (p = 0.009). Conclusion: In this real-life cohort of hospitalized elderly patients, the coexistence of COPD and HF significantly worsened prognosis at one year. This finding may help to better define the care needs of this population
    • …
    corecore