31 research outputs found

    EuroFlow Lymphoid Screening Tube (LST) data base for automated identification of blood lymphocyte subsets

    Get PDF
    In recent years the volume and complexity of flow cytometry data has increased substantially. This has led to a greater number of identifiable cell populations in a single measurement. Consequently, new gating strategies and new approaches for cell population definition are required. Here we describe how the EuroFlow Lymphoid Screening Tube (LST) reference data base for peripheral blood (PB) samples was designed, constructed and validated for automated gating of the distinct lymphoid (and myeloid) subsets in PB of patients with chronic lymphoproliferative disorders (CLPD). A total of 46 healthy/reactive PB samples which fulfilled predefined technical requirements, were used to construct the LST-PB reference data base. In addition, another set of 92 PB samples (corresponding to 10 healthy subjects, 51 B-cell CLPD and 31 T/NK-cell CLPD patients), were used to validate the automated gating and cell-population labeling tools with the Infinicyt software. An overall high performance of the LST-PB data base was observed with a median percentage of alarmed cellular events of 0.8% in 10 healthy donor samples and of 44.4% in CLPD data files containing 49.8% (range: 1.3–96%) tumor cells. The higher percent of alarmed cellular events in every CLPD sample was due to aberrant phenotypes (75.6% cases) and/or to abnormally increased cell counts (86.6% samples). All 18 (22%) data files that only displayed numerical alterations, corresponded to T/NK-cell CLPD cases which showed a lower incidence of aberrant phenotypes (41%) vs B-cell CLPD cases (100%). Comparison between automated vs expert-bases manual classification of normal (r2 = 0.96) and tumor cell populations (rho = 0.99) showed a high degree of correlation. In summary, our results show that automated gating of cell populations based on the EuroFlow LST-PB data base provides an innovative, reliable and reproducible tool for fast and simplified identification of normal vs pathological B and T/NK lymphocytes in PB of CLPD patients

    Evolution of the use of corticosteroids for the treatment of hospitalised COVID-19 patients in Spain between March and November 2020: SEMI-COVID national registry

    Get PDF
    Objectives: Since the results of the RECOVERY trial, WHO recommendations about the use of corticosteroids (CTs) in COVID-19 have changed. The aim of the study is to analyse the evolutive use of CTs in Spain during the pandemic to assess the potential influence of new recommendations. Material and methods: A retrospective, descriptive, and observational study was conducted on adults hospitalised due to COVID-19 in Spain who were included in the SEMI-COVID- 19 Registry from March to November 2020. Results: CTs were used in 6053 (36.21%) of the included patients. The patients were older (mean (SD)) (69.6 (14.6) vs. 66.0 (16.8) years; p < 0.001), with hypertension (57.0% vs. 47.7%; p < 0.001), obesity (26.4% vs. 19.3%; p < 0.0001), and multimorbidity prevalence (20.6% vs. 16.1%; p < 0.001). These patients had higher values (mean (95% CI)) of C-reactive protein (CRP) (86 (32.7-160) vs. 49.3 (16-109) mg/dL; p < 0.001), ferritin (791 (393-1534) vs. 470 (236- 996) µg/dL; p < 0.001), D dimer (750 (430-1400) vs. 617 (345-1180) µg/dL; p < 0.001), and lower Sp02/Fi02 (266 (91.1) vs. 301 (101); p < 0.001). Since June 2020, there was an increment in the use of CTs (March vs. September; p < 0.001). Overall, 20% did not receive steroids, and 40% received less than 200 mg accumulated prednisone equivalent dose (APED). Severe patients are treated with higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%. Conclusions: Patients with greater comorbidity, severity, and inflammatory markers were those treated with CTs. In severe patients, there is a trend towards the use of higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%

    Search for patterns by combining cosmic-ray energy and arrival directions at the Pierre Auger Observatory

    Get PDF
    Energy-dependent patterns in the arrival directions of cosmic rays are searched for using data of the Pierre Auger Observatory. We investigate local regions around the highest-energy cosmic rays with E > = 6×1019 eV by analyzing cosmic rays with energies above E > = 5×1018 eV arriving within an angular separation of approximately 15°. We characterize the energy distributions inside these regions by two independent methods, one searching for angular dependence of energy-energy correlations and one searching for collimation of energy along the local system of principal axes of the energy distribution. No significant patterns are found with this analysis. The comparison of these measurements with astrophysical scenarios can therefore be used to obtain constraints on related model parameters such as strength of cosmic-ray deflection and density of point sources

    Impact of Pre-Analytical and Analytical Variables Associated with Sample Preparation on Flow Cytometric Stainings Obtained with EuroFlow Panels

    No full text
    Simple Summary Objective interpretation of flow cytometry may be hampered by a lack of standardized sample preparation procedures. The EuroFlow consortium conducted a series of experiments to determine the potential impact of different pre-analytical and analytical factors on the variability of results in terms of relative cell populations distribution and marker expression levels. The experiments were performed on healthy donors and patients with different hematological malignancies (e.g., acute leukemia, lymphoma, multiple myeloma, and myelodysplastic syndrome) to mimic real-world clinical settings. Overall, the results showed that sample storage conditions, anticoagulant use, and sample processing protocol might need to be tailored for sample and cell type(s), as well as to the specific markers evaluated. However, defining of well-balanced boundaries for storage time to 24 h, staining-acquisition delay to 3 h, and choosing a washing buffer of pH within the range of 7.2 to 7.8 would be a valid recommendation for most applications and circumstances described herein. Objective interpretation of FC results may still be hampered by limited technical standardization. The EuroFlow consortium conducted a series of experiments to determine the impact of different variables on the relative distribution and the median fluorescence intensity (MFI) of markers stained on different cell populations, from both healthy donors and patients' samples with distinct hematological malignancies. The use of different anticoagulants; the time interval between sample collection, preparation, and acquisition; pH of washing buffers; and the use of cell surface membrane-only (SM) vs. cell surface plus intracytoplasmic (SM+CY) staining protocols, were evaluated. Our results showed that only monocytes were represented at higher percentages in EDTA- vs. heparin-anticoagulated samples. Application of SM or SM+CY protocols resulted in slight differences in the percentage of neutrophils and debris determined only with particular antibody combinations. In turn, storage of samples for 24 h at RT was associated with greater percentage of debris and cell doublets when the plasma cell disorder panel was used. Furthermore, 24 h storage of stained cells at RT was selectively detrimental for MFI levels of CD19 and CD45 on mature B- and T-cells (but not on leukemic blasts, clonal B- and plasma cells, neutrophils, and NK cells). The obtained results showed that the variables evaluated might need to be tailored for sample and cell type(s) as well as to the specific markers compared; however, defining of well-balanced boundaries for storage time, staining-to-acquisition delay, and pH of washing buffer would be a valid recommendation for most applications and circumstances described herein

    Impact of Pre-Analytical and Analytical Variables Associated with Sample Preparation on Flow Cytometric Stainings Obtained with EuroFlow Panels

    No full text
    Simple Summary Objective interpretation of flow cytometry may be hampered by a lack of standardized sample preparation procedures. The EuroFlow consortium conducted a series of experiments to determine the potential impact of different pre-analytical and analytical factors on the variability of results in terms of relative cell populations distribution and marker expression levels. The experiments were performed on healthy donors and patients with different hematological malignancies (e.g., acute leukemia, lymphoma, multiple myeloma, and myelodysplastic syndrome) to mimic real-world clinical settings. Overall, the results showed that sample storage conditions, anticoagulant use, and sample processing protocol might need to be tailored for sample and cell type(s), as well as to the specific markers evaluated. However, defining of well-balanced boundaries for storage time to 24 h, staining-acquisition delay to 3 h, and choosing a washing buffer of pH within the range of 7.2 to 7.8 would be a valid recommendation for most applications and circumstances described herein. Objective interpretation of FC results may still be hampered by limited technical standardization. The EuroFlow consortium conducted a series of experiments to determine the impact of different variables on the relative distribution and the median fluorescence intensity (MFI) of markers stained on different cell populations, from both healthy donors and patients' samples with distinct hematological malignancies. The use of different anticoagulants; the time interval between sample collection, preparation, and acquisition; pH of washing buffers; and the use of cell surface membrane-only (SM) vs. cell surface plus intracytoplasmic (SM+CY) staining protocols, were evaluated. Our results showed that only monocytes were represented at higher percentages in EDTA- vs. heparin-anticoagulated samples. Application of SM or SM+CY protocols resulted in slight differences in the percentage of neutrophils and debris determined only with particular antibody combinations. In turn, storage of samples for 24 h at RT was associated with greater percentage of debris and cell doublets when the plasma cell disorder panel was used. Furthermore, 24 h storage of stained cells at RT was selectively detrimental for MFI levels of CD19 and CD45 on mature B- and T-cells (but not on leukemic blasts, clonal B- and plasma cells, neutrophils, and NK cells). The obtained results showed that the variables evaluated might need to be tailored for sample and cell type(s) as well as to the specific markers compared; however, defining of well-balanced boundaries for storage time, staining-to-acquisition delay, and pH of washing buffer would be a valid recommendation for most applications and circumstances described herein.Stemcel biology/Regenerative medicine (incl. bloodtransfusion
    corecore