21 research outputs found

    GripAble: an accurate, sensitive and robust digital device for measuring grip strength

    Get PDF
    Introduction: Grip strength is a reliable biomarker of overall health and physiological well-being. It is widely used in clinical practice as an outcome measure. This paper demonstrates the measurement characteristics of GripAble, a wireless mobile handgrip device that measures grip force both isometrically and elastically-resisted for assessment and training of hand function. Methods: A series of bench tests were performed to evaluate GripAble's grip force measurement accuracy and sensitivity. Measurement robustness was evaluated through repeated drop tests interwoven with error verification test phases. Results: GripAble's absolute measurement error at the central position was under 0.81 and 1.67 kg (95th percentiles; N = 47) when measuring elastically and isometrically, respectively, providing similar or better accuracy than the industry-standard Jamar device. Sensitivity was measured as 0.062 ± 0.015 kg (mean ± std; 95th percentiles: [0.036, 0.089] kg; N = 47), independent of the applied force. There was no significant performance degradation following impact from 30 drops from a height >1.5 m. Conclusion: GripAble is an accurate and reliable grip strength dynamometer. It is highly sensitive and robust, which in combination with other novel features (e.g. portability, telerehabilitation and digital data tracking) enable broad applicability in a range of clinical caseloads and environments

    The Impact of Stiffness in Bimanual Versus Dyadic Interactions Requiring Force Exchange.

    Get PDF
    During daily activities, humans routinely manipulate objects bimanually or with the help of a partner. This work explored how bimanual and dyadic coordination modes are impacted by the object's stiffness, which conditions inter-limb haptic communication. For this, we recruited twenty healthy participants who performed a virtual task inspired by object handling, where we looked at the initiation of force exchange and its continued maintenance while tracking. Our findings suggest that while individuals and dyads displayed different motor behaviours, which may stem from the dyad's need to estimate their partner's actions, they exhibited similar tracking accuracy. For both coordination modes, increased stiffness resulted in better tracking accuracy and more correlated motions, but required a larger effort through increased average torque. These results suggest that stiffness may be a key consideration in applications such as rehabilitation, where bimanual or external physical assistance is often provided

    miR-181a regulates multiple pathways in hypopharyngeal squamous cell carcinoma

    Get PDF
    MicroRNAs (miRNAs) constitute a class of small non-coding RNAs that play essential roles in a variety of biological processes including apoptosis, proliferation and differentiation. Altered expression of miRNAs in head and neck cancer has been reported, but the consequences of aberrant expression of specific miRNAs on cancer pathways remain vague. Therefore, it is important to identify and elucidate pathways that may be regulated by specific miRNAs in this disease. miR-181a was up-regulated in head and neck versus normal tissues, thus pathway analysis was performed to profile the changes in the activities of ten signaling pathways relevant to cancer influenced by down-regulation of miR-181a. Expression of four pathway reporters were significantly increased (p53/DNA damage, TGFβ, MAPK/ERK and MAPK/JNK), while expression of two pathway reporters were decreased (Wnt and NFkB) upon miR-181a down-regulation. Notch, Myc/Max, hypoxia and cell cycle/pRB-E2F pathways were not significantly affected by miR-181a down-regulation. This study provides insight into the understanding of miRNA regulation on major cancer pathways.Key words: MicroRNA, head and neck cancer, miR-181a, pathway analysis, luciferase assay, FaDu cell line, transfection, qRT-PCR

    Transgenesis in Animal Agriculture: Addressing Animal Health and Welfare Concerns

    Get PDF
    The US Food and Drug Administration’s final Guidance for Industry on the regulation of transgenesis in animal agriculture has paved the way for the commercialization of genetically engineered (GE) farm animals. The production-related diseases associated with extant breeding technologies are reviewed, as well as the predictable welfare consequences of continued emphasis on prolificacy at the potential expense of physical fitness. Areas in which biotechnology could be used to improve the welfare of animals while maintaining profitability are explored along with regulatory schema to improve agency integration in GE animal oversight

    Bimanual coordination during a physically coupled task in unilateral spastic cerebral palsy children

    No full text
    Background Single object bimanual manipulation, or physically-coupled bimanual tasks, are ubiquitous in daily lives. However, the predominant focus of previous studies has been on uncoupled bimanual actions, where the two hands act independently to manipulate two disconnected objects. In this paper, we explore interlimb coordination among children with unilateral spastic cerebral palsy (USCP), by investigating upper limb motor control during a single object bimanual lifting task. Methods 15 children with USCP and 17 typically developing (TD) children performed a simple single-object bimanual lifting task. The object was an instrumented cube that can record the contact force on each of its faces alongside estimating its trajectory during a prescribed two-handed lifting motion. The subject’s performance was measured in terms of the duration of individual phases, linearity and monotonicity of the grasp-to-load force synergy, interlimb force asymmetry, and movement smoothness. Results Similar to their TD counterparts, USCP subjects were able to produce a linear grasp-to-load force synergy. However, they demonstrated difficulties in producing monotonic forces and generating smooth movements. No impairment of anticipatory control was observed within the USCP subjects. However, our analysis showed that the USCP subjects shifted the weight of the cube onto their more-abled side, potentially to minimise the load on the impaired side, which suggests a developed strategy of compensating for inter-limb asymmetries, such as muscle strength. Conclusion Bimanual interaction with a single mutual object has the potential to facilitate anticipation and sequencing of force control in USCP children unlike previous studies which showed deficits during uncoupled bimanual actions. We suggest that this difference could be partly due to the provision of adequate cutaneous and kinaesthetic information gathered from the dynamic exchange of forces between the two hands, mediated through the physical coupling

    Influence of visual-coupling on bimanual coordination in unilateral spastic cerebral palsy

    No full text
    10.1109/ICORR.2019.8779390IEEE International Conference on Rehabilitation Robotics2019-June1013-101

    Modernising grip dynamometry: Inter-instrument reliability between GripAble and Jamar

    Get PDF
    Introduction: Maximum grip strength (MGS) is a reliable biomarker of overall health and physiological well-being. Therefore, an accurate and reliable measurement device is vital for ensuring the validity of the MGS assessment. This paper presents GripAble, a mobile hand grip device for the assessment of MGS. GripAble’s performance was evaluated using an inter-instrument reliability test against the widely used Jamar PLUS+ dynamometer. Methods: MGS data from sixty-three participants (N = 63, median (IQR) age = 29.0 (29.5) years, 33 M/30 F) from both hands using GripAble and Jamar PLUS+ were collected and compared. Intraclass correlation (ICC), regression, and Bland and Altman analysis were performed to evaluate the inter-instrument reliability and relationship in MGS measurements between GripAble and Jamar PLUS+ . Results: GripAble demonstrates good-to-excellent inter-instrument reliability to the Jamar PLUS+ with ICC3,1 = 0.906 (95% CI [0.87—0.94]). GripAble’s MGS measurement is equivalent to 69% (95% CI [0.67—0.71]%) of Jamar PLUS+’s measurement. There is a proportional difference in mean MGS between the two devices, with the difference in MGS between GripAble and Jamar PLUS+ increasing with MGS. Conclusion: The GripAble is a reliable tool for measuring grip strength. However, the MGS readings from GripAble and Jamar PLUS+ should not be interchanged for serial measurements of the same patient, nor be translated directly from one device to the other. A new normative MGS data using GripAble will be collected and accessed through the software for immediate comparison to age and gender-matched subpopulations
    corecore