48 research outputs found
Recommended from our members
Arts on the edge conference: 30 March - 3 April Perth 1998 Western Australia
Direct numerical simulations of turbulent flow over regular arrays of urban-like, cubical obstacles are reported. Results are analysed in terms of a formal spatial averaging procedure to enable interpretation of the flow within the arrays as a canopy flow, and of the flow above as a rough wall boundary layer. Spatial averages of the mean velocity, turbulent stresses and pressure drag are computed. The statistics compare very well with data from wind-tunnel experiments. Within the arrays the time-averaged flow structure gives rise to significant ‘dispersive stress’ whereas above the Reynolds stress dominates. The mean flow structure and turbulence statistics depend significantly on the layout of the cubes. Unsteady effects are important, especially in the lower canopy layer where turbulent fluctuations dominate over the mean flow
The impact of boundary layer height on air pollution concentrations in London – early results from the ClearfLo project.
The ClearfLo projects aims to understand the processes generating pollutants like ozone, NOx and particulate
matter and their interaction with the urban atmospheric boundary layer. ClearfLo (www.clearflo.ac.uk) is a
large multi-institution NERC-funded project that is establishing integrated measurements of the meteorology,
composition and particulate loading of London’s urban atmosphere, complemented by an ambitious modeling
programme.
The project established a new long-term measurement infrastructure in London encompassing measurement
capabilities at street level and at elevated sites. These measurements were accompanied by high resolution mod-
eling with the UK Met Office Unified model and WRF. This combined measuring/modelling approach enables
us to identify the seasonal cycle in the meteorology and composition, together with the controlling processes.
Two intensive observation periods in January/February 2012 and during the Olympics in summer 2012 measured
London’s atmosphere with higher level of detail. Data from these IOPs will enable us (i) to determine the vertical
structure and evolution of the urban atmosphere (ii) to determine the chemical controls on ozone production,
particularly the role of biogenic emissions and (iii) to determine the processes controlling the evolution of the size,distribution and composition of particulate matter.
We present results from the wintertime IOP in London focusing on a wintertime pollution episode during
January 2012. We compare measured concentrations from top of BT Tower in central London with rural background measurements and determine the processes leading to the urban increment in pollutant concentrations.
Therefore, we combine high-resolution simulations with the Met Office Unified Model for London and mixing
layer heights derived from lidar measurements with air quality measurements in central London in order to
quantify the role the boundary layer depth plays for London’s concentrations
Recommended from our members
Initial results from Phase 2 of the international urban energy balance model comparison
Urban land surface schemes have been developed to model the distinct features of the urban surface and the associated energy exchange processes. These models have been developed for a range of purposes and make different assumptions related to the inclusion and representation of the relevant processes. Here, the first results of Phase 2 from an international comparison project to evaluate 32 urban land surface schemes are presented. This is the first large-scale systematic evaluation of these models. In four stages, participants were given increasingly detailed information about an urban site for which urban fluxes were directly observed. At each stage, each group returned their models' calculated surface energy balance fluxes. Wide variations are evident in the performance of the models for individual fluxes. No individual model performs best for all fluxes. Providing additional information about the surface generally results in better performance. However, there is clear evidence that poor choice of parameter values can cause a large drop in performance for models that otherwise perform well. As many models do not perform well across all fluxes, there is need for caution in their application, and users should be aware of the implications for applications and decision making
Convalescent plasma in patients admitted to hospital with COVID-19 (RECOVERY): a randomised controlled, open-label, platform trial
Background:
Many patients with COVID-19 have been treated with plasma containing anti-SARS-CoV-2 antibodies. We aimed to evaluate the safety and efficacy of convalescent plasma therapy in patients admitted to hospital with COVID-19.
Methods:
This randomised, controlled, open-label, platform trial (Randomised Evaluation of COVID-19 Therapy [RECOVERY]) is assessing several possible treatments in patients hospitalised with COVID-19 in the UK. The trial is underway at 177 NHS hospitals from across the UK. Eligible and consenting patients were randomly assigned (1:1) to receive either usual care alone (usual care group) or usual care plus high-titre convalescent plasma (convalescent plasma group). The primary outcome was 28-day mortality, analysed on an intention-to-treat basis. The trial is registered with ISRCTN, 50189673, and ClinicalTrials.gov, NCT04381936.
Findings:
Between May 28, 2020, and Jan 15, 2021, 11558 (71%) of 16287 patients enrolled in RECOVERY were eligible to receive convalescent plasma and were assigned to either the convalescent plasma group or the usual care group. There was no significant difference in 28-day mortality between the two groups: 1399 (24%) of 5795 patients in the convalescent plasma group and 1408 (24%) of 5763 patients in the usual care group died within 28 days (rate ratio 1·00, 95% CI 0·93–1·07; p=0·95). The 28-day mortality rate ratio was similar in all prespecified subgroups of patients, including in those patients without detectable SARS-CoV-2 antibodies at randomisation. Allocation to convalescent plasma had no significant effect on the proportion of patients discharged from hospital within 28 days (3832 [66%] patients in the convalescent plasma group vs 3822 [66%] patients in the usual care group; rate ratio 0·99, 95% CI 0·94–1·03; p=0·57). Among those not on invasive mechanical ventilation at randomisation, there was no significant difference in the proportion of patients meeting the composite endpoint of progression to invasive mechanical ventilation or death (1568 [29%] of 5493 patients in the convalescent plasma group vs 1568 [29%] of 5448 patients in the usual care group; rate ratio 0·99, 95% CI 0·93–1·05; p=0·79).
Interpretation:
In patients hospitalised with COVID-19, high-titre convalescent plasma did not improve survival or other prespecified clinical outcomes.
Funding:
UK Research and Innovation (Medical Research Council) and National Institute of Health Research
Turbulent boundary layer flow over undulating surfaces
SIGLEAvailable from British Library Document Supply Centre- DSC:D60148 / BLDSC - British Library Document Supply CentreGBUnited Kingdo
Recommended from our members
Wind profile and drag coefficient over mature and growing ocean surface wave spectra
Recommended from our members
Boundary-layer ventilation by baroclinic lifecycles
Ventilation of the boundary layer has an important effect on local and regional air quality and is a prerequisite for long-range pollution transport. Once in the free troposphere, pollutants can alter the chemical composition of the troposphere and impact on the Earth's radiative forcing. Idealised baroclinic life cycles, LC1 and LC2, have been simulated in a three-dimensional dry hemispheric model in the presence of boundary-layer turbulent fluxes. A passive tracer is added to the simulations to represent pollution emitted at, or near, the surface. A simple conveyor-belt diagnostic is developed to objectively identify regions of the boundary layer that can be ventilated by either warm or cold conveyor belts. Transport of pollutants within and above the boundary layer is examined on synoptic scales. Three different physical mechanisms are found to interact with each other to ventilate pollutants out of the boundary layer. These mechanisms are turbulent mixing within the boundary layer, horizontal advection due to Ekman convergence and divergence within the boundary layer, and advection by
the warm conveyor belt. The mass of tracer ventilated by the two life
cycles is remarkably similar given the differences in frontal structure,
suggesting that the large-scale baroclinicity is an effective constraint
on ventilation