634 research outputs found

    Introductory report [on European citizenship, fundamental rights and the third pillar].

    Get PDF
    This report introduced the proceedings of a symposium session that was devoted to an examination of the subjects of European Union citizenship, fundamental rights and Title VI (third pillar) Treaty on the European Union (TEU) in the context of the 1996 Intergovernmental Conference. There are strong links between these three important issues and other sessions of the symposium, in particular 'Elaboration of a fundamental treaty' (Session 1) and 'Democratization of the European Union' (Session 2). However, these three subjects were considered to be deserving of independent treatment given their widely perceived importance for the future of the Union. The report is followed by notes from the discussion, a summary of conclusions drawn during the session, and a list of other participants and their papers

    Accelerated X-ray Structure Elucidation of a 36 kDa Muramidase/Transglycosylase Using wARP

    Get PDF
    The X-ray structure of the 36kDa soluble lytic transglycosylase from Escherichia coli has been determined starting with the multiple isomorphous replacement method with inclusion of anomalous scattering at 2.7 Å resolution. Subsequently, before any model building was carried out, phases were extended to 1.7 Å, resolution with the weighted automated refinement procedure wARP, which gave a dramatic improvement in the phases. The electron-density maps from wARP were of outstanding quality for both the main chain and the side chains of the protein, which allowed the time spent on the tracing, interpretation and building of the X-ray structure to be substantially shortened. The structure of the soluble lyric transglycosylase was refined at 1.7 Å, resolution with X-PLOR to a final crystallographic R factor of 18.9%. Analysis of the wARP procedure revealed that the use of the maximum-likelihood refinement in wARP gave much better phases than least-squares refinement, provided that the ratio of reflections to protein atom parameters was approximately 1.8 or higher. Furthermore, setting aside 5% of the data for an Rfree test set had a negative effect on the phase improvement. The mean WwARP, a weight determined at the end of the wARP procedure and based on the variance of structure factors from six individually refined wARP models, proved to be a better indicator than the Rfree factor to judge different phase improvement protocols. The elongated Slt35 structure has three domains named the alpha, beta and core domains. The alpha domain contains mainly α-helices, while the beta domain consists of a five-stranded antiparallel β-sheet flanked by a short α-helix. Sandwiched between the alpha and beta domains is the core domain, which bears some resemblance to the fold of the catalytic domain of the previously elucidated 70 kDa soluble lytic transglycosylase from E. coli. The putative active site is at the bottom of a large deep groove in the core domain.

    wARP

    Full text link
    wARP is a procedure that substantially improves crystallographic phases (and subsequently electron-density maps) as an additional step after density-modification methods such as solvent flattening and averaging. The initial phase set is used to create a number of dummy atom models which are subjected to least-squares or maximum-likelihood refinement and iterative model updating in an automated refinement procedure (ARP). Averaging of the phase sets calculated from the refined output models and weighting of structure factors by their similarity to an average vector results in a phase set that improves and extends the initial phases substantially. An important requirement is that the native data have a maximum resolution beyond \sim2.4 Ã…. The wARP procedure shortens the time-consuming step of model building in crystallographic structure determination and helps to prevent the introduction of errors

    Pioneering Robotic Liver Surgery in Germany: First Experiences with Liver Malignancies

    Get PDF
    Background Minimally invasive liver surgery is growing worldwide with obvious benefits for the treated patients. These procedures maybe improved by robotic techniques, which add several innovative features. In Germany, we were the first surgical department implementing robotic assisted minimally invasive liver resections. Material and methods Between June 2013 and March 2015, we performed robotic based minimally invasive liver resections in nine patients with malignant liver disease. Five off these patients suffered from primary and four from secondary liver malignancies. We retrospectively analyzed the perioperative variables of these patients and the oncological follow up. Results Mean age of the patients was 63 years (range 45–71). One patient suffered from intrahepatic cholangiocellular, four from hepatocellular carcinoma, and four patients from colorectal liver metastases. In six patients, left lateral liver resection, in two cases single segment resection, and in one case minimally invasive guided liver ablation were performed. Five patients underwent previous abdominal surgery. Mean operation time was 312 min (range 115–458 min). Mean weight of the liver specimens was 182 g (range 62–260 g) and mean estimated blood loss was 251 ml (range 10–650 ml). The mean tumor size was 4.4 cm (range 3.5–5.5 cm). In all cases, R0 status was confirmed with a mean margin of 0.6 cm (range 0.1–1.5 cm). One patient developed small bowel fistula on postoperative day 5, which could be treated conservatively. No patient died. Mean hospital stay of the patients was 6 days (range 3–10 days). During a mean follow up of 12 months (range 1–21 months), two patients developed tumor recurrence. Conclusion Robotic-based liver surgery is feasible in patients with primary and secondary liver malignancies. To achieve perioperative parameters comparable to open settings, the learning curve must be passed. Minor liver resections are good candidates to start this technique. But the huge benefits of robotic-based liver resections should be expected in extended procedures beyond minor liver resections with the currently available technology

    Right-hand-side updating for fast computing of genomic breeding values

    Get PDF
    Since both the number of SNPs (single nucleotide polymorphisms) used in genomic prediction and the number of individuals used in training datasets are rapidly increasing, there is an increasing need to improve the efficiency of genomic prediction models in terms of computing time and memory (RAM) required

    ARP

    Full text link

    Pioneering Robotic Liver Surgery in Germany: First Experiences with Liver Malignancies

    Get PDF
    Background Minimally invasive liver surgery is growing worldwide with obvious benefits for the treated patients. These procedures maybe improved by robotic techniques, which add several innovative features. In Germany, we were the first surgical department implementing robotic assisted minimally invasive liver resections. Material and methods Between June 2013 and March 2015, we performed robotic based minimally invasive liver resections in nine patients with malignant liver disease. Five off these patients suffered from primary and four from secondary liver malignancies. We retrospectively analyzed the perioperative variables of these patients and the oncological follow up. Results Mean age of the patients was 63 years (range 45–71). One patient suffered from intrahepatic cholangiocellular, four from hepatocellular carcinoma, and four patients from colorectal liver metastases. In six patients, left lateral liver resection, in two cases single segment resection, and in one case minimally invasive guided liver ablation were performed. Five patients underwent previous abdominal surgery. Mean operation time was 312 min (range 115–458 min). Mean weight of the liver specimens was 182 g (range 62–260 g) and mean estimated blood loss was 251 ml (range 10–650 ml). The mean tumor size was 4.4 cm (range 3.5–5.5 cm). In all cases, R0 status was confirmed with a mean margin of 0.6 cm (range 0.1–1.5 cm). One patient developed small bowel fistula on postoperative day 5, which could be treated conservatively. No patient died. Mean hospital stay of the patients was 6 days (range 3–10 days). During a mean follow up of 12 months (range 1–21 months), two patients developed tumor recurrence. Conclusion Robotic-based liver surgery is feasible in patients with primary and secondary liver malignancies. To achieve perioperative parameters comparable to open settings, the learning curve must be passed. Minor liver resections are good candidates to start this technique. But the huge benefits of robotic-based liver resections should be expected in extended procedures beyond minor liver resections with the currently available technology

    ARP/wARP and molecular replacement: the next generation

    Get PDF
    A systematic test shows how ARP/wARP deals with automated model building for structures that have been solved by molecular replacement. A description of protocols in the flex-wARP control system and studies of two specific cases are also presented

    Incisional hernia after liver transplantation: mesh-based repair and what else?

    Get PDF
    Abstract Purpose Incisional hernia (IH) is not uncommon after liver transplantation (LT). We investigated the long-term outcome of mesh-based hernia repair using an inlay-onlay technique. Methods Our analysis was based on a prospective collected database of all LT recipients from our hospital over a period of 15 years. We analyzed clinical data including the period between LT and hernia development, the size and localization of the hernia, the length of in-hospital stay, immunosuppression, and postoperative morbidity, as well as follow-up data. The median follow-up period was 120 (range 12–200) months. Results Among a total of 220 patients who underwent a collective 239 LTs, 29 (13%) were found to have an IH after a median period of 27.5 months (range 3–96 months). There were 12 (41%) men and 17 (59%) women, with a median age of 51 years. The median size of the IH was 13 cm (range 2–30 cm) and the median in-hospital stay was 6 days. Mild postoperative complications developed in seven patients, including two onlay mesh infections. One patient (3.4%) suffered recurrence. Conclusion Mesh-based hernia repair using the inlay/onlay technique represents an effective and safe method for patients with an IH after LT, without additional risk from continuous immunosuppression
    • …
    corecore