1,096 research outputs found
Unusual superexchange pathways in a Ni triangular lattice of NiGaS with negative charge-transfer energy
We have studied the electronic structure of the Ni triangular lattice in
NiGaS using photoemission spectroscopy and subsequent model
calculations. The cluster-model analysis of the Ni 2 core-level spectrum
shows that the S 3 to Ni 3 charge-transfer energy is -1 eV and the
ground state is dominated by the configuration ( is a S 3 hole).
Cell perturbation analysis for the NiS triangular lattice indicates that
the strong S 3 hole character of the ground state provides the enhanced
superexchange interaction between the third nearest neighbor sites.Comment: 10 pages, 5 figures, accepted to PR
THz Wave Propagation on Strip Lines: Devices, Properties, and Applications
We report the propagation characteristics of THz pulses on micro-strip-lines and coplanar strip-lines, in which low permittivity polymer materials are used as the dielectric layer or the substrate. As a result of the low attenuation and small dispersion in the devices, the spectral width up to 3 THz can be achieved even after the 1 mm propagation. Spectroscopic characterizations of liquid or powder specimens are demonstrated using the devices. We also show a possibility of realizing a very low attenuation using a quadrupole mode in three strip coplanar lines on the polymer substrate
Improvements in quantum efficiency of excitonic emissions in ZnO epilayers by the elimination of point defects
科研費報告書収録論文(課題番号:18350092/研究代表者:大友明/高効率酸化亜鉛系青色・紫外発光素子の開発
Strut protrusion and shape impact on endothelial shear stress: insights from pre-clinical study comparing Mirage and Absorb bioresorbable scaffolds
Protrusion of scaffold struts is related with local coronary flow dynamics that can promote scaffold restenosis and thrombosis. That fact has prompted us to investigate in vivo the protrusion status of different types of scaffolds and their relationship with endothelial shear stress (ESS) distributions. Six Absorb everolimus-eluting Bioresorbable Vascular Scaffolds (Absorb, Abbott Vascular) and 11 Mirage sirolimus-eluting Bioresorbable Microfiber Scaffolds (Mirage, Manli Cardiology) were implanted in coronaries of eight mini pigs. Optical coherence tomography (OCT) was performed post-scaffold implantation and obtained images were fused with angiographic data to reconstruct the three dimensional coronary anatomy. Blood flow simulation was performed and ESS distribution was estimated for each scaffold. Protrusion distance was estimated using a dedicated software. Correlation between OCT-derived protrusion and ESS distribution was assessed for both scaffold groups. A significant difference was observed in the protrusion distances (156 ± 137 µm for Absorb, 139 ± 153 µm for Mirage; p = 0.035), whereas difference remained after adjusting the protrusion distances according to the luminal areas. Strut protrusion of Absorb is inversely correlated with ESS (r = -0.369, p < 0.0001), whereas in Mirage protrusion was positively correlated with EES (r = 0.192, p < 0.0001). Protrusion distance was higher in Absorb than in Mirage. The protrusion of the thick quadratic struts of Absorb has a tendency to lower shear stress in the close vicinity of struts. However, circular shape of the less thick struts of Mirage didn't show this trend in creating zone of recirculation around the struts. Strut geometry has different effect on the relationship between protrusion and shear stress in Absorb and Mirage scaffolds
Agreement of wall shear stress distribution between two core laboratories using three-dimensional quantitative coronary angiography
Wall shear stress (WSS) estimated in models reconstructed from intravascular imaging and 3-dimensional-quantitative coronary angiography (3D-QCA) data provides important prognostic information and enables identification of high-risk lesions. However, these analyses are time-consuming and require expertise, limiting WSS adoption in clinical practice. Recently, a novel software has been developed for real-time computation of time-averaged WSS (TAWSS) and multidirectional WSS distribution. This study aims to examine its inter-corelab reproducibility. Sixty lesions (20 coronary bifurcations) with a borderline negative fractional flow reserve were processed using the CAAS Workstation WSS prototype to estimate WSS and multi-directional WSS values. Analysis was performed by two corelabs and their estimations for the WSS in 3 mm segments across each reconstructed vessel was extracted and compared. In total 700 segments (256 located in bifurcated vessels) were included in the analysis. A high intra-class correlation was noted for all the 3D-QCA and TAWSS metrics between the estimations of the two corelabs irrespective of the presence (range: 0.90–0.92) or absence (range: 0.89–0.90) of a coronary bifurcation, while the ICC was good-moderate for the multidirectional WSS (range: 0.72–0.86). Lesion level analysis demonstrated a high agreement of the two corelabls for detecting lesions exposed to an unfavourable haemodynamic environment (WSS > 8.24 Pa, κ = 0.77) that had a high-risk morphology (area stenosis > 61.3%, κ = 0.71) and were prone to progress and cause events. The CAAS Workstation WSS enables reproducible 3D-QCA reconstruction and computation of WSS metrics. Further research is needed to explore its value in detecting high-risk lesions
Quantitative plane-resolved crystal growth and dissolution kinetics by coupling in situ optical microscopy and diffusion models : the case of salicylic acid in aqueous solution
The growth and dissolution kinetics of salicylic acid crystals are investigated in situ by focusing on individual microscale crystals. From a combination of optical microscopy and finite element method (FEM) modeling, it was possible to obtain a detailed quantitative picture of dissolution and growth dynamics for individual crystal faces. The approach uses real-time in situ growth and dissolution data (crystal size and shape as a function of time) to parametrize a FEM model incorporating surface kinetics and bulk to surface diffusion, from which concentration distributions and fluxes are obtained directly. It was found that the (001) face showed strong mass transport (diffusion) controlled behavior with an average surface concentration close to the solubility value during growth and dissolution over a wide range of bulk saturation levels. The (1̅10) and (110) faces exhibited mixed mass transport/surface controlled behavior, but with a strong diffusive component. As crystals became relatively large, they tended to exhibit peculiar hollow structures in the end (001) face, observed by interferometry and optical microscopy. Such features have been reported in a number of crystals, but there has not been a satisfactory explanation for their origin. The mass transport simulations indicate that there is a large difference in flux across the crystal surface, with high values at the edge of the (001) face compared to the center, and this flux has to be redistributed across the (001) surface. As the crystal grows, the redistribution process evidently can not be maintained so that the edges grow at the expense of the center, ultimately creating high index internal structures. At later times, we postulate that these high energy faces, starved of material from solution, dissolve and the extra flux of salicylic acid causes the voids to close
Recommended from our members
Age-related differences in brain activity during physical and imagined sit-to-stand in healthy young and older adults
Purpose: The purpose of this study was to investigate whether healthy young and older people differ in self-reported movement time and brain activity pattern as indicated by electroencephalography during physical and imagined sit-to-stand movements.
Participants and Methods: Twenty healthy young (aged 20–29 years) and 19 older (aged 60–69) participants performed physical and imagined sit-to-stand movements while their self-reported movement times and electroencephalography were recorded.
Results: No age-related differences were found in self-reported movement time for physical or imagined sit-to-stand. In the frontal and temporal regions, electroencephalography showed a beta wave (14–17 Hz) for all conditions in both young and older adults. In the parietal and occipital regions, during physical sit-to-stand trials, both groups showed a beta wave in both regions. During imagined sit-to-stand trials, however, young participants showed a high alpha wave (10.6–13 Hz) in the parietal and a low alpha wave (8–10.5 Hz) in the occipital region, whereas older participants showed all three (alpha and beta) waves in the parietal and occipital regions.
Conclusion: Although no age-related differences were found in the ability to generate motor imagery, brain activity pattern as indicated by electroencephalography was dissimilar between young and older participants during motor imagery
- …