    Clinical Experience with the PillCam Patency Capsule prior to Video Capsule Endoscopy: A Real-World Experience

    Get PDF
    Background. In patients with known or suspected risk factors for gastrointestinal stenosis, the PillCam patency capsule (PC) is given before a video capsule endoscopy (VCE) in order to minimize the risk of capsule retention (CR). CR is considered unlikely upon excretion of the PC within 30 hours, excretion in an undamaged state after 30 hours, or radiological projection to the colon. Methods. We performed a retrospective analysis of 38 patients with risk factors for CR, who received a PC from 02/2013 to 04/2015 at Klinikum Augsburg. Results. Sixteen of our 38 patients observed a natural excretion after a mean time of 34 hours past ingestion. However, only 8 patients observed excretion within 30 hours, as recommended by the company. In 20 patients passage of the PC into the colon was shown via RFID-scan or radiological imaging (after 33 and 45 hours, resp.). Only 2 patients showed a pathologic PC result. In consequence, 32 patients received the VCE; no CR was observed. Conclusion. Our data indicates that a VCE could safely be performed even if the PC excretion time is longer than 30 hours and the excreted PC was not screened for damage

    Clinical Study Clinical Experience with the PillCam Patency Capsule prior to Video Capsule Endoscopy: A Real-World Experience

    Get PDF
    Background. In patients with known or suspected risk factors for gastrointestinal stenosis, the PillCam patency capsule (PC) is given before a video capsule endoscopy (VCE) in order to minimize the risk of capsule retention (CR). CR is considered unlikely upon excretion of the PC within 30 hours, excretion in an undamaged state after 30 hours, or radiological projection to the colon. Methods. We performed a retrospective analysis of 38 patients with risk factors for CR, who received a PC from 02/2013 to 04/2015 at Klinikum Augsburg. Results. Sixteen of our 38 patients observed a natural excretion after a mean time of 34 hours past ingestion. However, only 8 patients observed excretion within 30 hours, as recommended by the company. In 20 patients passage of the PC into the colon was shown via RFID-scan or radiological imaging (after 33 and 45 hours, resp.). Only 2 patients showed a pathologic PC result. In consequence, 32 patients received the VCE; no CR was observed. Conclusion. Our data indicates that a VCE could safely be performed even if the PC excretion time is longer than 30 hours and the excreted PC was not screened for damage

    Detection Rate and Clinical Relevance of Ink Tattooing during Balloon-Assisted Enteroscopy

    Get PDF
    Background and Aims. Balloon-assisted enteroscopy (BAE) is a well-established tool in the diagnosis and therapy of small bowel diseases. Ink tattooing of the small bowel is used to mark pathologic lesions or the depth of small bowel insertion. The purpose of this study was to determine the safety, the detection rate, and the clinical relevance of ink tattooing during BAE. Methods. We performed a retrospective analysis of all 81 patients who received an ink tattooing during BAE between 2010 and 2015. Results. In all patients, ink tattooing was performed with no complications. 26 patients received a capsule endoscopy after BAE. The tattoo could be detected via capsule endoscopy in 19 of these 26 patients. The tattoo of the previous BAE could be detected via opposite BAE in 2 of 11 patients. In 9 patients, ink tattooing influenced the choice of approach for reenteroscopy. In 7 patients, the tattoo was used for intraoperative localization and in 3 patients for intraoperative localization as well as for reenteroscopy. The intraoperative detection rate of the tattoo was 100%. Conclusion. Ink tattooing of the small intestine is a safe endoscopic procedure to mark the depth of scope insertion or a pathologic lesion during balloon-assisted enteroscopy

    Modified endoscopic mucosal resection techniques for treating precancerous colorectal lesions

    No full text
    Endoscopic mucosal resection (EMR) is a technique allowing efficacious and minimally invasive resection of precancerous lesions across the entire gastrointestinal tract. However, conventional EMR, involving injection of fluid into the submucosal space, is imperfect, given the high rate of recurrence of post-endoscopic resection adenoma, especially after piecemeal resection. In light of these observations, modifications of the technique have been proposed to overcome the weakness of conventional EMR. Some of them were designed to maximize the chance of en bloc resection—cap-assisted EMR, underwater EMR, tip-in EMR, precutting, assisted by ligation device—while others were designed to minimize the complications (cold EMR). In this review, we present their modes of action and summarize the evidence regarding their efficacy and safety

    Comparison of capsule endoscopy and magnetic resonance (MR) enteroclysis in suspected small bowel disease

    No full text
    BACKGROUND AND AIMS: Small bowel MR enteroclysis and wireless capsule endoscopy (WCE) are new diagnostic tools for the investigation of the small bowel. The aim of this study was to compare the diagnostic yield of WCE with MR enteroclysis in the detection of small bowel pathologies. METHODS: A total of 36 patients were included in the study. Indications for imaging of the small bowel were proven or suspected small bowel Crohn's disease (CD; n=18), obscure gastrointestinal (GI) bleeding (n=14) and tumour surveillance (n=4). RESULTS: In patients with Crohn's disease WCE detected significantly more inflammatory lesions in the first two segments of the small bowel compared with MR enteroclysis (12 patients vs. 1 patient, p=0.016). In 5 out of 14 (36%) patients with GI bleeding, angiodysplasia was detected as a possible bleeding source. Three of these patients had active bleeding sites detected by WCE. One patient had scattered inflammation of the mucosa. MR enteroclysis did not reveal any intestinal abnormalities in this patient group. MR enteroclysis provided extraintestinal pathologies in 10 out of 36 (28%) patients. CONCLUSION: In patients with Crohn's disease WCE revealed significantly more inflammatory lesions in the proximal and middle part of the small bowel in comparison to MR enteroclysis, whereas in patients with obscure GI bleeding WCE was superior to MR enteroclysis