13 research outputs found
A reduced-order strategy for 4D-Var data assimilation
This paper presents a reduced-order approach for four-dimensional variational
data assimilation, based on a prior EO F analysis of a model trajectory. This
method implies two main advantages: a natural model-based definition of a mul
tivariate background error covariance matrix , and an important
decrease of the computational burden o f the method, due to the drastic
reduction of the dimension of the control space. % An illustration of the
feasibility and the effectiveness of this method is given in the academic
framework of twin experiments for a model of the equatorial Pacific ocean. It
is shown that the multivariate aspect of brings additional
information which substantially improves the identification procedure. Moreover
the computational cost can be decreased by one order of magnitude with regard
to the full-space 4D-Var method
Comparison of gravimetry and dynamic dilution for the generation of reference gas mixtures with known composition of CO2 at atmospheric amount fraction
Carbon dioxide (CO2) is the most important greenhouse gas from human activities. Its
concentration has been growing continuously in the atmosphere reaching a current annual
average of 410 micromol·mol-1. Reliable determinations of the atmospheric CO2 concentration
are of great importance for both environmental protection and development of models used in
climate change predictions. The production of reference mixtures of known concentration and
the establishment of sound analytical methods are key activities for the achievement of reliable
information on the pollution level and the improvement and maintenance of a worldwide
coherent measurement system for the determination of greenhouse gases.
The present work deals with the advantages and drawbacks of two methods that assure
metrological traceability to SI to measurement results.
The first method, more accurate, is based on the gravimetric preparation of gas mixtures
in high pressure cylinders, but it requires long preparation procedures.
The second one, based on dynamic dilution, represents a more flexible alternative for
gas mixture generation. The method requires diluting devices such as mass flow controllers
which canalize and portion the gas flows in a mixing chamber. This method enables to generate
gas mixtures at the desired amount fraction and can be applied also for the production of
mixtures with unstable or reactive components. However, it might lead to larger uncertainties.
At INRiM, these methods are used to prepare gas mixtures with specific CO2 amount
fractions, which are periodically verified by a Non-Dispersive Infrared analyser to check the
stability of the mixture composition over time
Evidence of a systematic underestimation of free sulfur dioxide by the aeration-oxidation method approved by OIV
Calcul du champ demagnetisant dans un materiau magnetique de geometrie quelconque par une technique de transformee de Fourier et la methode du domaine fictif
Theme 4 - Simulation et optimisation de systemes complexes - Projet IDOPTAvailable from INIST (FR), Document Supply Service, under shelf-number : 14802 E, issue : a.1997 n.3289 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueSIGLEFRFranc
Confronto di misura sulla determinazione della concentrazione dell’anidride solforosa libera in una soluzione di similvino
Il metodo di misura descritto nella Risoluzione OIV-OENO 591A-2018 dell’Organizzazione
Internazionale della Vigna e del Vino per la determinazione della concentrazione di SO2 nel vino,
oltre ad essere il metodo di riferimento, è comunemente utilizzato nei laboratori di analisi e nelle
cantine viti-vinicole per semplicità del metodo, costo e precisione dei risultati. Tuttavia, da ricerche
in letteratura e da esperimenti effettuati su soluzioni di similvino, è risultato verosimile che con
questo metodo non si riesca a determinare la totalità della concentrazione di SO2, presente
unicamente in forma libera. Di conseguenza è stato organizzato e svolto un confronto di misura fra
nove laboratori del Piemonte su un campione di similvino per verificare il recupero massimo di SO2
libera che è possibile estrarre da un campione a concentrazione nota. Il risultato più importante di
questo primo confronto è stato la conferma che con il metodo ufficiale OIV la determinazione della
concentrazione di SO2 libera in similvino è soltanto parziale. Questo argomento andrebbe
approfondito per capire se con qualche accorgimento strumentale/tecnologico sia possibile
raggiungere una determinazione complessiva più aderente al valore di concentrazione determinato
per via gravimetrica. Questo anche in vista di affrontare la stessa procedura su una matrice reale e
complessa come il vino, dove si devono determinare la SO2 libera e la SO2 totale, senza contare il
possibile intervento degli interferenti