267 research outputs found

    Severity of postoperative recurrence in Crohn's disease: Correlation between endoscopic and sonographic findings

    Get PDF
    Background: Crohn's disease (CD) recurrence is currently assessed by ileocolonoscopy. Small intestine contrast ultrasonography (SICUS) visualizes the small bowel lesions in CD, although its role after curative resection is undefined. We aimed to investigate the accuracy of SICUS in assessing CD recurrence after ileocolonic resection when using ileocolonoscopy as a gold standard. The correlation between the bowel wall thickness (BWT) measured by SICUS and the endoscopic score of recurrence was also assessed. Methods: The analysis included 72 CD patients with ileocolonic resection requiring ileocolonoscopy, undergoing SICUS within 6 months. Recurrence was assessed by ileocolonoscopy using the Rutgeerts' score. SICUS was performed after PEG ingestion and findings compatible with recurrence included: increased BWT (>3 mm), bowel dilation (>25 mm) or stricture (<10 mm). Results: Ileocolonoscopy detected recurrence in 67/72 (93%) patients. SICUS detected findings compatible with recurrence in 62/72 (86%) patients (5 false negative (FN), 4 false positive (FP), 1 true negative (TN), 62 true positive (TP)), showing a 92.5% sensitivity, 20% specificity, and 87.5% accuracy for detecting CD recurrence. The BWT detected by SICUS was correlated with the Rutgeerts' score (P = 0.0001; r = 0.67). The median BWT, the extent of the ileal lesions, and the prestenotic dilation were higher in patients with an endoscopic degree of recurrence ≥3 versus ≤2 (P < 0.001) and the lumen diameter was lower in patients with a Rutgeerts' score ≥3 versus ≤2 (P < 0.0001). Conclusions: Although SICUS and ileocolonoscopy provide different views of the small bowel, SICUS shows a significant correlation with the endoscopic findings. SICUS may represent an alternative noninvasive technique for assessing CD recurrence after ileocolonic resection. Copyright © 2009 Crohn's & Colitis Foundation of America, Inc

    Wearable augmented reality platform for aiding complex 3D trajectory tracing

    Get PDF
    Augmented reality (AR) Head-Mounted Displays (HMDs) are emerging as the most efficient output medium to support manual tasks performed under direct vision. Despite that, technological and human-factor limitations still hinder their routine use for aiding high-precision manual tasks in the peripersonal space. To overcome such limitations, in this work, we show the results of a user study aimed to validate qualitatively and quantitatively a recently developed AR platform specifically conceived for guiding complex 3D trajectory tracing tasks. The AR platform comprises a new-concept AR video see-through (VST) HMD and a dedicated software framework for the effective deployment of the AR application. In the experiments, the subjects were asked to perform 3D trajectory tracing tasks on 3D-printed replica of planar structures or more elaborated bony anatomies. The accuracy of the trajectories traced by the subjects was evaluated by using templates designed ad hoc to match the surface of the phantoms. The quantitative results suggest that the AR platform could be used to guide high-precision tasks: on average more than 94% of the traced trajectories stayed within an error margin lower than 1 mm. The results confirm that the proposed AR platform will boost the profitable adoption of AR HMDs to guide high precision manual tasks in the peripersonal space

    Non-invasive techniques for assessing postoperative recurrence in Crohn's disease

    Get PDF
    Postoperative recurrence after ileo-colonic resection is a feature of Crohn's Disease (CD), almost 73% of patients show endoscopic recurrence at 1 year and 90% at 3 years. After surgical resection for CD, symptoms may be related to the surgical resection itself. Moreover, the development of an early severe endoscopic recurrence within 1 year represents a risk factor for early clinical recurrence. On the basis of these observations, the early detection and assessment of asymptomatic endoscopic recurrence may allow a timely and appropriate treatment of CD patients after ileo-colonic resection. At this purpose, conventional colonoscopy with ileoscopy currently represents the gold standard for assessing CD recurrence, graded according to the Rutgeerts' score. Lesions compatible with CD recurrence can be also detected by conventional radiology, including small bowel follow through and enema, both associated with a high radiation exposure. Due to the ineluctable course of CD after resection, and to the need of a proper follow up for assessing CD recurrence, several alternative, non invasive techniques have been searched in order to assess the post-operative recurrence, including: faecal alpha 1-antitrypsin clearance, faecal calprotectin, 99Tc-HMPAO scintigraphy, virtual colonoscopy, ultrasonography and, more recently, wireless capsule endoscopy (WCE) and Small Intestine Contrast Ultrasonography (SICUS). Among these, current evidences suggest that in experienced hands, ultrasound examination by SICUS represents a non-invasive technique useful for assessing recurrence in CD patients under regular follow up after surgery. The same findings are suggested for WCE, although the impact risk related to the recurrence or to the surgical anastomosis itself limits the use of this non-invasive technique for assessing CD recurrence after surgery. © 2008 Editrice Gastroenterologica Italiana S.r.l

    Design of a sensorized guiding catheter for in situ laser fenestration of endovascular stent

    Get PDF
    PURPOSE: The in situ fenestration of a standard endograft is currently limited by difficulties in targeting the fenestration site under fluoroscopic control and by the lack of a safe method to perforate the graft. Evidence in the literature suggests the use of a 3 D electromagnetic navigator to accurately guide the endovascular instruments to the target and a laser to selectively perforate the graft. The aim of this work is to provide design guidelines to develop a sensorized catheter to guide the laser tool to the fenestration site and conduct preliminary testing of the feasibility of the proposed solution. Matherials and methods: Different catheter designs were delineated starting from engineering considerations, then prototypes were preliminarily tested to collect surgeon opinions and to steer the design process toward the preferred solution reported by the user. Finally, mechanical simulations were performed with CathCAD, a design software system for the development of composite tubing for endovascular catheters. RESULTS: Based on surgeon feedback, a 9-French steerable catheter with a stabilization system was designed. CathCAD simulations allowed us to define the construction parameters (e.g., materials and geometric constrains) for the fabrication of composite tubes with mechanical properties (flexural, axial, and torsional rigidities) compatible with target values in the literature for guiding catheters. CONCLUSION: The presented results preliminarily demonstrate the clinical reasonability and feasibility of the designed tool in terms of mechanical properties. Further mechanical tests and extensive in vitro clinical trials are required prior to animal testing

    Ileal lesions in patients with ulcerative colitis after ileo-rectal anastomosis: Relationship with colonic metaplasia

    Get PDF
    Aim: To assess whether in ulcerative colitis (UC) patients with ileo-rectal anastomosis (IRA), ileal lesions may develop in the neo-terminal-ileum and their possible relation with phenotypic changes towards colonic epithelium. Methods: A total of 19 patients with IRA under regular follow up were enrolled, including 11 UC and 8 controls (6 Crohn's disease, CD; 1 familial adenomatous polyposis, FAP; 1 colon cancer, colon K). Ileal lesions were identified by ileoscopy with biopsies taken from the ileum (involved and uninvolved) and from the rectal stump. Staining included HE and immunohistochemistry using monoclonal antibodies against colonic epithelial protein CEP (Das-1) and human tropomyosin isoform 5, hTM5 (CG3). Possible relation between development of colonic metaplasia and ileal lesions was investigated. Results: Stenosing adenocarcinoma of the rectal stump was detected in 1 UC patient. The neo-terminal ileum was therefore investigated in 10/11 UC patients. Ileal ulcers were detected in 7/10 UC, associated with colonic metaplasia in 4/7 (57.1%) and Das-1 and CG3 reactivity in 3/4 UC. In controls, recurrence occurred in 4/6 CD, associated with colonic metaplasia in 3/4 and reactivity with Das-1 and CG3 in 2/3. Conclusion: Present findings suggest that in UC, ileal lesions associated with changes towards colonic epithelium may develop also after IRA. Changes of the ileal content after colectomy may contribute to the development of colonic metaplasia, leading to ileal lesions both in the pouch and in the neo-terminal ileum after IRA

    Wireless capsule endoscopy and proximal small bowel lesions in Crohn's disease

    Get PDF
    AIM: To investigate the prevalence of proximal small bowel (SB) lesions detected by wireless capsule endoscopy (WCE) in Crohn's disease (CD). METHODS: WCE was performed in 64 patients: 32 with CD of the distal ileum, and 32 controls with iron-deficiency anemia (IDA) or diarrhea. WCE was performed using the Given SB-WCE, followed by small intestine contrast ultrasonography (SICUS). Findings compatible with CD by using WCE included erosions, aphthoid or deep ulcers, and strictures/stenosis. RESULTS: WCE detected proximal SB lesions in 16/32 (50%) patients (14 aphthoid ulcers, 2 deep ulcers, one stricture), which appeared not to be related to clinical parameters [epigastric pain, age, smoking, non-steroidal anti-inflammatory drugs (NSAIDs), IDA]. Among patients with proximal SB lesions, 6 (37%) were smokers, 3 (19%) NSAID users, 3 (19%) had epigastric pain and 4 (25%) had IDA. SICUS detected proximal SB lesions in 3/32 patients (19%) also showing lesions with WCE. No correlations were observed between proximal SB lesions assessed by WCE or by SICUS (χ2 = 1.5, P = 0.2). CONCLUSION: The use of WCE allows the detection of previously unknown upper SB lesions in a high proportion of patients with a previous diagnosis of CD involving the distal ileum. © 2010 Baishideng

    The Use Of Reverse Transcription-pcr For The Diagnosis Of X-linked Chronic Granulomatous Disease.

    Get PDF
    Chronic granulomatous disease (CGD) is an inherited disorder of the innate immune system characterized by a defective oxidative burst of phagocytes and subsequent impairment of their microbicidal activity. Mutations in one of the NADPH-oxidase components affect gene expression or function of this system, leading to the phenotype of CGD. Defects in gp91-phox lead to X-linked CGD, responsible for approximately 70% of CGD cases. Investigation of the highly heterogeneous genotype of CGD patients includes mutation analysis, Northern blot or Western blot assays according to the particular case. The aim of the present study was to use reverse transcription (RT)-PCR for the analysis of molecular defects responsible for X-linked CGD in eight Brazilian patients and to assess its potential for broader application to molecular screening in CGD. Total RNA was prepared from Epstein B virus-transformed B-lymphocytes and reverse transcribed using random hexamers. The resulting cDNA was PCR-amplified by specific and overlapping pairs of primers designed to amplify three regions of the gp91-phox gene: exons 1-5, 3-9, and 7-13. This strategy detected defective gp91-phox expression in seven patients. The RT-PCR results matched clinical history, biochemical data (nitroblue tetrazolium or superoxide release assay) and available mutation analysis in four cases. In three additional cases, RT-PCR results matched clinical history and biochemical data. In another case, RT-PCR was normal despite a clinical history compatible with CGD and defective respiratory burst. We conclude that this new application of RT-PCR analysis--a simple, economical and rapid method--was appropriate for screening molecular defects in 7 of 8 X-linked CGD patients.37625-3
    corecore